Manual Sentry Sentry Xpress Sentry Xpress 4.0

16 pages 2.87 mb
Download

Go to site of 16

Summary
  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 1

    The Sentry Xpress 4.0 micro processor is manufactured by the Orton Ceramic Foundation and displays the CE mark. Hr ./Min. When Lit HIGHER °C °F When Off When Lit ST ART/ STOP L OWER Program Review Run MICRO PROCESSOR TM SENTRY Xpress 4.0 Enter Program Skip Seg. Add Hold Change T emp. T/C Offset Alarm Delay Review 1 START/STOP Key Starts and stops ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 2

    2 Single-Speed/Ramp-Hold ©2004, by Paragon Industries, L.P. IM-221/2-06 Contents General Guidelines . . . . . . . . . . . . . . . . . 3 Time and Temperature Display . . . . . . . . . . . . . . . . . . . 3 Operation Begins from the IdLE Display . . . . . . . . . . . . 3 Thermocouple Inspection . . . . . . . . . . . . . . . . . . . . . . . 3 A Rapid ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 3

    3 General Guidelines Time and Temperature Display Center Dot: Time A center dot appears dur - ing time display. It separates hours from minutes. (Exam - ple: 1 hour, 30 minutes dis - plays as 01.30.) During tem - perature display, the dot disappears. Right-Hand Dot: °C When temperature is displayed in °C, a dot appears in the lower right. In °F ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 4

    4 Single-Speed/Ramp-Hold Note: Press during delay to end the delay and begin the firing. The maximum delay is 99 hours and 59 minutes. Power Failures After a power failure, the controller will continue firing provided that: I The kiln temperature is above 212°F / 100°C when the power comes back on. I The temperature dropped no more than 72°F / 4 ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 5

    5 Rate Each segment must include a rate, which is degrees of temperature change per hour. The kiln will fire at full power when the rate is 1799°F/999°C. Full power displays as . Note: To enter full power from , press the key once. Hold Hold is the length of time that you want the kiln to re- main at the target temperature. Hold is also called so ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 6

    6 Single-Speed/Ramp-Hold Ramp-Hold programs in memory. Programs are numbered Pro1 - Pro4. Type of Firing Suggested Firing Mode Enameling Single-Speed Silver Clay Single-Speed Glass Bead Annealing Ramp-Hold Glass Fusing Ramp-Hold Glass Slumping Ramp-Hold Lost Wax Ramp-Hold Selecting a Firing Mode From display, press once. Press the key several times ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 7

    7 Rate Temp. Segment °F/°C °F/°C Hold 1 500/277 1450/788 00.00 2 100/55 700/371 00.00 The first segment is the heating segment. The second one is the cooling segment. The controller does not use mi - nus numbers for cooling. Just enter a lower target tempera - ture than that of the previous segment. If you prop the lid or door for a fast coolin ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 8

    8 Single-Speed/Ramp-Hold Advanced Fe a t u r e s Skip Segment works only in Ramp-Hold programs. Add Hold Time, Temperature Edit, and Alarm work in both Single-Speed and Ramp-Hold firings. Skip Segment Skip Segment jumps the firing from the current segment to the next one. During a Ramp-Hold firing, press the . will appear. Press . The current segme ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 9

    9 Lost W ax Burnout CAUTION: Only kilns with vent holes are designed for lost wax burnout. However, you may be able to use a kiln without the vent hole provided that you open the door ½” during venting. CAUTION: Always use a wax tray. Note: These instructions apply to injection wax that melts at 200°F, not pattern waxes and plastics that melt a ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 10

    10 Single-Speed/Ramp-Hold Display Messages (Page 9) Ready for you to enter an alarm temperature. When the kiln reaches that tempera - ture, the alarm will sound. ( also flashes when the alarm sounds.) (page 9) Ready for you to edit the target temperature of the current Ramp-Hold segment during firing. Example: You are fusing glass to a temperature ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 11

    11 (pages 7, 8) These are Ramp-Hold programs stored in memory. etc. (Rate) (page 8) This appears in Ramp-Hold programming for each segment. 1, 2, etc. are segment numbers. Enter the rate of temper - ature change for that segment. Rate is figured in de - grees of temperature change per hour. Example: A temperature rise of 100° in two hours = 50° r ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 12

    12 Single-Speed/Ramp-Hold FE Error Messages FE 1 Memory Read/Write Failure FE 2 RAM Failure FE 3 OEM Factory Data Corruption FE 4 Thermocouple “Noise” FE 5 Software Error To return to from an FE code Try pressing any key. If that doesn’t work, turn the power off for 10 seconds. Call the factory if the error message re - mains when you turn th ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 13

    13 T rouble Shooter Problem: Controller display is blank. No heat in kiln. I Is the kiln connected to the power? I Has the circuit breaker tripped or fuse blown? I Is power reaching the wall receptacle? Test with a voltmeter or a test light if you are not sure. I Has the kiln switch box ½ amp fuse blown? The kiln’s ½ amp fuse is located in the ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 14

    14 Single-Speed/Ramp-Hold Problem: Controller display turns on. No heat in kiln. I Is the relay making its normal clicking sound? Test the elements with an ohmmeter: Element Resistance Test UNPLUG kiln/disconnect the power. Open the kiln’s switch box. Make sure the wires connecting the relay to the elements are secure. If connec - tions are okay, ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 15

    15 Index Add Hold Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 bAdP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 calibrating the controller . . . . . . . . . . . . . . . . . . . . . . . . 12 cas ...

  • Sentry Sentry Xpress Sentry Xpress 4.0 - page 16

    16 Single-Speed/Ramp-Hold Shorthand Instructions These instructions may be confusing until you have read more detailed instructions on Single-Speed, page 6, or Ramp-Hold, page 8. Read the safety guidelines, page 3. After pressing the keys in left column, the center message will appear. Single-Speed Keys to Press Display thru (Not Down Arrow) Select ...

Manufacturer Sentry Category Thermometer

Documents that we receive from a manufacturer of a Sentry Sentry Xpress Sentry Xpress 4.0 can be divided into several groups. They are, among others:
- Sentry technical drawings
- Xpress Xpress 4.0 manuals
- Sentry product data sheets
- information booklets
- or energy labels Sentry Sentry Xpress Sentry Xpress 4.0
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sentry Sentry Xpress Sentry Xpress 4.0.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sentry Sentry Xpress Sentry Xpress 4.0, service manual, brief instructions and user manuals Sentry Sentry Xpress Sentry Xpress 4.0. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sentry Sentry Xpress Sentry Xpress 4.0.

A complete manual for the device Sentry Sentry Xpress Sentry Xpress 4.0, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sentry Sentry Xpress Sentry Xpress 4.0 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sentry Sentry Xpress Sentry Xpress 4.0.

A complete Sentry manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sentry Sentry Xpress Sentry Xpress 4.0 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sentry Sentry Xpress Sentry Xpress 4.0, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sentry Sentry Xpress Sentry Xpress 4.0, that we can find in the current document
3. Tips how to use the basic functions of the device Sentry Sentry Xpress Sentry Xpress 4.0 - which should help us in our first steps of using Sentry Sentry Xpress Sentry Xpress 4.0
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sentry Sentry Xpress Sentry Xpress 4.0
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sentry Sentry Xpress Sentry Xpress 4.0 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sentry Sentry Xpress Sentry Xpress 4.0?

Use the form below

If you did not solve your problem by using a manual Sentry Sentry Xpress Sentry Xpress 4.0, ask a question using the form below. If a user had a similar problem with Sentry Sentry Xpress Sentry Xpress 4.0 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)