    Instruction Guide – UA-774 Dual Memor y Auto-Inflate Blood Pressur e Monitor ...

  • A&D UA-774 - page 2

    Please r ead this important information befor e using your monitor . ☞ Please r emember that only a medical practitioner is qualified to interpr et your blood pr essure measur ements. Use of this device should not r eplace r egular medical examinations. ☞ Have your physician r eview your pr ocedure for using this device. He or she will want to ...

  • A&D UA-774 - page 3

    TM Congratulations on pur chasing a state-of-the-art LifeSour ce blood pr essur e monitor—one of the most technologically advanced monitors available today . Designed for ease of use and accuracy , this monitor will facilitate your daily blood pr essur e r egimen. Physicians agr ee that daily self-monitoring of blood pr essur e is an important st ...

  • A&D UA-774 - page 4

    WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-774 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 BEFORE YOU ST ART . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . ...

  • A&D UA-774 - page 5

    LifeSource Health Line (T oll-Free): 1-888-726-9966 Display Symbol Recommended Action Measur ement is in progr ess, r emain as still as possible. T ake measurement again and consult with your physician. Replace all batteries with new ones when the indicator blinks. T ry the measurement again. Remain very still during the measur ement. Fasten the cu ...

  • A&D UA-774 - page 6

    E-3 MONITOR COMPONENTS ? ? In Canada (T oll-Free): 1-800-463-5414 ST ART BUTTONS TUBE AC ADAPTER JACK SYSTOLIC DISPLA Y AIR CONNECTOR AIR SOCKET CUFF BA TTERY COMP ARTMENT DIASTOLIC DISPLA Y PULSE DISPLA Y ...

  • A&D UA-774 - page 7

    LifeSource Health Line (T oll-Free): 1-888-726-9966 Y ou must install 4 type AA (1.5 volt) batteries, or use the AC Adapter (see page E-11 for using the Monitor with AC Adapter) and attach the cuff to the monitor befor e using it. T o install batteries (or r eplace them if the “Low Battery” symbol appears on display), pr oceed as follows: 1. Re ...

  • A&D UA-774 - page 8

    In Canada (T oll-Free): 1-800-463-5414 E- 5 USE SMALL CUFF USE LARGE CUFF PROPER FIT RANGE INDEX Using the corr ect cuff size is impor tant for an accurate reading. A cuff that is too lar ge will produce a r eading that is lower than the corr ect blood pr essure; a cuf f that is too small will pr oduce a r eading that is higher than the corr ect bl ...

  • A&D UA-774 - page 9

    LifeSource Health Line (T oll-Free): 1-888-726-9966 T AKING YOUR BLOOD PRESSURE The UA-774 has several modes available to fit your blood pr essur e monitoring needs. Nor mal Measurement with Readings Stor ed in Memory Pr ess the ST AR T 1 or ST AR T 2 button. Y our blood pressur e is measur ed and the r eading is stored into memory . Each ST AR T b ...

  • A&D UA-774 - page 10

    E- 7 Now you ar e r eady . Follow these simple steps: 1. Sit comfortably with your left arm r esting on a flat surface so that the center of your upper arm is at the same height as your heart. 2. Lay left arm on the table, palm up and thr ead cuff end thr ough metal loop, smooth side against arm. Then position the tube off-center towar d the inner ...

  • A&D UA-774 - page 11

    LifeSource Health Line (T oll-Free): 1-888-726-9966 E-8 T AKING YOUR BLOOD PRESSURE NOTE: If you wish to stop inflation at any time, press either ST ART button again. NOTE: The maximum cuff pressure is set at 280 mmHg. If it reaches 280 mmHg, the auto exhaust will be triggered and cuff pressure will deflate to 0. 6. When the inflation is complete, ...

  • A&D UA-774 - page 12

    E-9 The memory function on the UA-774 blood pr essur e monitor is designed for two people. For each ST AR T button, the monitor can stor e up to 30 r eadings in memory . T o keep track of previous measur ements accurately , we recommend that you use the same ST AR T button each time you take a blood pressur e r eading. T o recall pr evious measur e ...

  • A&D UA-774 - page 13

    LifeSource Health Line (T oll-Free): 1-888-726-9966 E- 1 0 The UA-774 Blood Pr essur e Monitor provides a blood pr essure and pulse rate measur ement even when an irr egular heartbeat occurs. An irr egular heartbeat is defined as a hear tbeat that varies by 25% fr om the average of all heartbeat intervals during the blood pr essur e measurement. It ...

  • A&D UA-774 - page 14

    USING THE MONITOR WITH AC ADAPTER The UA-774 has an AC adapter jack to allow you to supply power fr om an outlet in your home. W e recommend you use only the exclusive AC adapter (Model TB:181) to avoid potential damage to the monitor . Connecting the AC adapter to the monitor: 1. Connect the AC adapter plug into the jack on the back of the monitor ...

  • A&D UA-774 - page 15

    LifeSource Health Line (T oll-Free): 1-888-726-9966 LifeSource Health Line (T oll-Free): 1-888-726-9966 ABOUT BLOOD PRESSURE ❤ E- 1 2 ❤ What Is Blood Pressure? Blood pr essur e is the for ce exerted by blood against the walls of the arteries. Systolic pr essure occurs when the hear t contracts; diastolic pr essur e occurs when the heart expands ...

  • A&D UA-774 - page 16

    E- 1 3 ❤ ABOUT BLOOD PRESSURE ❤ In Canada (T oll-Free): 1-800-463-5414 Assessing High Blood Pressure The following standar ds for assessing high blood pr essur e (without r egar d to age) have been established as a guideline. BP Classification Systolic (mmHg) Diastolic (mmHg) Normal <120 and <80 Pr ehypertension 120-139 or 80-89 Stage 1 H ...

  • A&D UA-774 - page 17

    LifeSource Health Line (T oll-Free): 1-888-726-9966 LifeSource Health Line (T oll-Free): 1-888-726-9966 E- 1 4 ❤ ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pr essur e r eadings taken in a doctor’ s office or hospital setting might be elevated as a r esult of appr ehension ...

  • A&D UA-774 - page 18

    E- 1 5 ❤ TM In Canada (T oll-Free): 1-800-463-5414 ...

  • A&D UA-774 - page 19

    LifeSource Health Line (T oll-Free): 1-888-726-9966 TROUBLESHOOTING ✓ Problem Nothing appears in the display , even when the power is turned on. The cuff does not inflate. The unit does not measur e. Readings ar e too high or too low . Other Probable cause Batteries ar e drained. Battery terminals ar e not in the corr ect position. Battery voltag ...

  • A&D UA-774 - page 20

    E- 1 7 Model . . . . . . . . . . . . . . . . . . .UA-774 T ype . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital character height . . . . . . . . . . . . . . . . . . . . . . .Pr essur e (16.0 mm)/ pulse (10.0 mm) . . . . . . . . . . . . . . . . . . . . . . .displayed simultaneously Memor y . . ...

  • A&D UA-774 - page 21

    CONT ACT INFORMA TION E- 1 8 Our pr oducts ar e designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and tr eatment options. Our full pr oduct line includes: Aner oid Blood Pressure Kits Blood Pressure Cuffs Digital Blood Pressure Monitors Digital Thermometers Hear t Rate ...

  • A&D UA-774 - page 22

    CONT ACT INFORMA TION A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com LifeSour ce is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:774 Printed in China 11/03 IMPORT ANT! If Y ou Need Assistance with the Se ...

Manufacturer A&D Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a A&D UA-774 can be divided into several groups. They are, among others:
- A&D technical drawings
- UA-774 manuals
- A&D product data sheets
- information booklets
- or energy labels A&D UA-774
All of them are important, but the most important information from the point of view of use of the device are in the user manual A&D UA-774.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals A&D UA-774, service manual, brief instructions and user manuals A&D UA-774. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product A&D UA-774.

Similar manuals

A complete manual for the device A&D UA-774, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use A&D UA-774 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of A&D UA-774.

A complete A&D manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual A&D UA-774 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the A&D UA-774, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the A&D UA-774, that we can find in the current document
3. Tips how to use the basic functions of the device A&D UA-774 - which should help us in our first steps of using A&D UA-774
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with A&D UA-774
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of A&D UA-774 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning A&D UA-774?

Use the form below

If you did not solve your problem by using a manual A&D UA-774, ask a question using the form below. If a user had a similar problem with A&D UA-774 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)