  • Desa VP5D - page 1

    Save this manual for future reference. INFRARED VENT -FREE PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL ® VP5D and VP10A WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life. — Do not store or use gasoline or other ...

  • Desa VP5D - page 2

    PROP ANE/LP GAS HEA TERS 2 ® VP5D AND VP10A 104273 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. Th ...

  • Desa VP5D - page 3

    OWNER’S MANUAL 3 104273 PRODUCT IDENTIFICA TION PRODUCT FEA TURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo igni ...

  • Desa VP5D - page 4

    PROP ANE/LP GAS HEA TERS 4 ® VP5D AND VP10A 104273 Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose ...

  • Desa VP5D - page 5

    OWNER’S MANUAL 5 104273 WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3, or applicable local code ...

  • Desa VP5D - page 6

    PROP ANE/LP GAS HEA TERS 6 ® VP5D AND VP10A 104273 AIR FOR COMBUSTION AND VENTILA TION Continued Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjo ...

  • Desa VP5D - page 7

    OWNER’S MANUAL 7 104273 36" 3" FLOOR CEILING Minimum Minimum T Of Carpeti n Combusti b 8" Minimum From Sides Of Heater Right Side Left Side 2. Mark two mounting screw locations on wall (see Figure 5). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater . Figure 5 - Mounting Screw Locations WA ...

  • Desa VP5D - page 8

    PROP ANE/LP GAS HEA TERS 8 ® VP5D AND VP10A 104273 Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting scr ...

  • Desa VP5D - page 9

    OWNER’S MANUAL 9 104273 CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduc ...

  • Desa VP5D - page 10

    PROP ANE/LP GAS HEA TERS 10 ® VP5D AND VP10A 104273 CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage he ...

  • Desa VP5D - page 11

    OWNER’S MANUAL 11 104273 OPERA TING HEA TER Continued LIGHTING INSTRUCTIONS 1. STOP! Read the safety inf ormation, page 10, column 3. 2. Make sur e equipment shutoff valve is fully open. 3. T urn control knob clockwise to the OFF position. 4. W ait fi ve (5) minutes to clear out any gas. Then smell for gas, including near the floor . If you smell ...

  • Desa VP5D - page 12

    PROP ANE/LP GAS HEA TERS 12 ® VP5D AND VP10A 104273 GRH/OV 008 BAD PILOT/LP GRH/OV 007 GOOD PILOT/LP INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pat- tern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermoc ...

  • Desa VP5D - page 13

    OWNER’S MANUAL 13 104273 TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode positioned wrong 2. Ignitor electrode broke ...

  • Desa VP5D - page 14

    PROP ANE/LP GAS HEA TERS 14 ® VP5D AND VP10A 104273 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is l ...

  • Desa VP5D - page 15

    OWNER’S MANUAL 15 104273 POSSIBLE CAUSE 1. Heater burning vapors from paint, hair spray , glues, etc. (See IMPORT ANT statement above) 2. Low fuel supply 3. Gas leak. See W arning statement at top of page 1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged 1. Gas leak. See W arning statement at top of page ...

  • Desa VP5D - page 16

    PROP ANE/LP GAS HEA TERS 16 ® VP5D AND VP10A 104273 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual. ODS/PILOT ILLUSTRA TED PA R T S BREAKDOWN VP5D 7-1 7-2 18 17 16 15 14 13 12 10 9 11 19 22 7 6 6 5 4 3 2 1 8 20 21 22 KEY PART NO. NUMBER ...

  • Desa VP5D - page 17

    OWNER’S MANUAL 17 104273 KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembly 1 3 099318-03 Grill Guard 1 4 101108-01 Grill Guard Clip 2 5 099469-02 Reflector Assembly 1 6 M15823-37 Screw Hex #8 x 1/4" 10 7 099059-03 ODS/Pilot Assembly 1 7-1 098514-01 Thermocouple 1 7-2 098594-01 Ignitor ...

  • Desa VP5D - page 18

    PROP ANE/LP GAS HEA TERS 18 ® VP5D AND VP10A 104273 You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190. You can also visit DESA International’s technical service web site at www.desatech.com. TECHNICAL SER VICE When Gas Pressure ...

  • Desa VP5D - page 19

    OWNER’S MANUAL 19 104273 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa VP5D - page 20

    INTERNA TIONAL W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VANGUARD VENT-FREE RESIDENT ...

Manufacturer Desa Category Gas Heater

Documents that we receive from a manufacturer of a Desa VP5D can be divided into several groups. They are, among others:
- Desa technical drawings
- VP5D manuals
- Desa product data sheets
- information booklets
- or energy labels Desa VP5D
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa VP5D.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa VP5D, service manual, brief instructions and user manuals Desa VP5D. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa VP5D.

Similar manuals

A complete manual for the device Desa VP5D, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa VP5D by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa VP5D.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa VP5D - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa VP5D, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa VP5D, that we can find in the current document
3. Tips how to use the basic functions of the device Desa VP5D - which should help us in our first steps of using Desa VP5D
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa VP5D
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa VP5D in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa VP5D?

Use the form below

If you did not solve your problem by using a manual Desa VP5D, ask a question using the form below. If a user had a similar problem with Desa VP5D it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)