For more information, visit www .fmiproducts.com W ARNING: If the information in this manual is not ...
-
FMI VMH26TPC - page 2
www .fmiproducts.com 1 131 1 1-01K 2 SAFETY T ABLE OF CONTENTS Safety .................................................................. 2 Local Codes......................................................... 4 Product Identication ........................................... 4 Product Features ................................................. 5 U ...
-
FMI VMH26TPC - page 3
www .fmiproducts.com 1 131 1 1-01 3 this heater or its controls can W ARNING: Do not allow fans ...
-
FMI VMH26TPC - page 4
www .fmiproducts.com 1 131 1 1-01K 4 SAFETY Continued 10. This repl ace need s fresh air vent ilat ion to run pro perl y . This repl ace has an Oxyg en Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the re - place if not enough fresh air is available. See Air for Combustion and V entilation , page 6. If replace keeps ...
-
FMI VMH26TPC - page 5
www .fmiproducts.com 1 131 1 1-01 5 PRODUCT FEA TURES ASSEMBL Y Figure 2 - Assembling Fireplace Log Screen Burner Support with Log Locator T abs Branch Support Shoulder Screw This replace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-fre ...
-
FMI VMH26TPC - page 6
www .fmiproducts.com 1 131 1 1-01K 6 ASSEMBL Y Continued 1. Lo cat e fou r b lac k phi lli ps sh eet me ta l screws from the hardware packet. 2. Rotate hood as shown in Figure 3. Make sure hood tabs point toward replace. 3. Insert hood tabs between bafe and lou - vers (see Figure 3). 4. Gently rot ...
-
FMI VMH26TPC - page 7
www .fmiproducts.com 1 131 1 1-01 7 ? ...
-
FMI VMH26TPC - page 8
www .fmiproducts.com 1 131 1 1-01K 8 W ARN IN G: If the area in wh ich ? ...
-
FMI VMH26TPC - page 9
www .fmiproducts.com 1 131 1 1-01 9 INST ALLA TION IMPORT ANT : V ent-free replaces add mois - ture to the air . Although this is benecial, installing replace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and V entilation, page 6. Note: Y our V ANT AGE HEARTH replace is d ...
-
FMI VMH26TPC - page 10
www .fmiproducts.com 1 131 1 1-01K 10 W ARNING: Maintain the minimum clearances shown ? ...
-
FMI VMH26TPC - page 11
www .fmiproducts.com 1 131 1 1-01 11 IMPORT ANT : When nishing your rebox, combustible materials W ARNING: Do not allow any ? ...
-
FMI VMH26TPC - page 12
www .fmiproducts.com 1 131 1 1-01K 12 W ARNING: Never modify or cover the louvered slots on the Installation If placing mantel above built-in replace, you must meet minimum clea rance between ...
-
FMI VMH26TPC - page 13
www .fmiproducts.com 1 131 1 1-01 13 INST ALLA TION Continued 9. Check all gas connections for leaks. See Checking Gas Connections, page 18. 1 0. Carefully insert fireplace into cabinet mantel (see Figure 13). Be careful not to scratch or damage hearth base or cabinet mantel. 1 1. Pla ce meta l trim on shou lde r screw s locat - ed on the side and ...
-
FMI VMH26TPC - page 14
www .fmiproducts.com 1 131 1 1-01K 14 INST ALLA TION Continued Figure 16 - Removing V alve Cover Shield 1 2 Remove Screw V alve Cover Shield Shoulder Screw Branch Support Snap Bushings Bottom Louver Assembly 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of heater cabine t, locate 4 mounti ng holes on outer c ...
-
FMI VMH26TPC - page 15
www .fmiproducts.com 1 131 1 1-01 15 INST ALLA TION Continued Figure 18 - Installing Switch Plate to V alve Cover Shield Switch Plate Screw V alve Cover Shield W ARNING: A licensed elec- ...
-
FMI VMH26TPC - page 16
www .fmiproducts.com 1 131 1 1-01K 16 INST ALLA TION Continued - ...
-
FMI VMH26TPC - page 17
www .fmiproducts.com 1 131 1 1-01 17 INST ALLA TION Continued Inst allat ion must include an equipm ent shutof f valve, union, and plugged 1/8" NPT tap. Lo - cate NPT tap within reach for test gauge hook up. NPT tap must be upstream from replace (see Figure 22). IMPORT ANT : Install equipment shutoff valve in an accessible location. Equipme ...
-
FMI VMH26TPC - page 18
www .fmiproducts.com 1 131 1 1-01K 18 INST ALLA TION Continued and connections, internal and external to unit, for leaks after ...
-
FMI VMH26TPC - page 19
www .fmiproducts.com 1 131 1 1-01 19 INST ALLA TION Continued CONNECTIONS 1. Op en eq uip me nt sh ut of f va lve (s ee Fi gur e 25, page 18). 2. Open main gas valve located on or near gas meter for natural gas or open pro - pane/LP supply tank valve. 3. M ...
-
FMI VMH26TPC - page 20
www .fmiproducts.com 1 131 1 1-01K 20 Note: If pilot does not stay lit, refer to T roubleshooting, page 24. Also contact a qua lie d servi ce pers on or gas suppl ier for repairs. Until repairs are made, light pilot with match. T o light pilot with match, see Manual Lighting Procedure, page 21. 7. Keep control knob pressed in for 30 sec- onds af ...
-
FMI VMH26TPC - page 21
www .fmiproducts.com 1 131 1 1-01 21 TO TURN OFF GAS Shutting Off Fireplace 1. T urn control knob clockwise to the OFF position. 2. T urn off all electric power to the appliance if service is to be performed. 3. Clo se equi pme nt shut of f valv e (see Figu re 25, page 18). THERMOST A T ...
-
FMI VMH26TPC - page 22
www .fmiproducts.com 1 131 1 1-01K 22 Thermocouple Pilot Burner Figure 31 - Correct Pilot Flame Pattern (Propane/LP Shown) Thermocouple Pilot Burner Figure 32 - Incorrect Pilot Flame Pattern (Propane/LP Shown) Figure 33 shows a correct burner ame pat - tern. Figure 34 shows an incorr ...
-
FMI VMH26TPC - page 23
www .fmiproducts.com 1 131 1 1-01 23 CLEANING AND MAINTENANCE 4. Check injector holder located at end of burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into primary air holes on injector holder . 6. In case any lar ge clum ps of dust have now been pushed into bu ...
-
FMI VMH26TPC - page 24
www .fmiproducts.com 1 131 1 1-01K 24 TROUBLESHOO TING ? ...
-
FMI VMH26TPC - page 25
www .fmiproducts.com 1 131 1 1-01 25 1 . Control knob not fully pressed in 2. Control knob not pressed in long enough 3. Safety interloc k system has been triggered 4. Equi pmen t shuto f f valve not fully open 5. Thermocouple connection loose at control valve 6. P i lo t fl a me n ot t ou c hi n g thermoc ...
-
FMI VMH26TPC - page 26
www .fmiproducts.com 1 131 1 1-01K 26 TROUBLESHOO TING Continued 1. Residues from manufac tur- ing processes 1. Turning control knob to HI position when burner is cold 2. Air in gas line 3. Air passageways on re - place blocked 4. Dirty or partially clogged burner orice 1. When heated, vapors from fu ...
-
FMI VMH26TPC - page 27
www .fmiproducts.com 1 131 1 1-01 27 ? ...
-
FMI VMH26TPC - page 28
www .fmiproducts.com 1 131 1 1-01K 28 SERVICE HINTS • pilot will not stay lit • burner will have delayed ignition • replace will not produce specied heat • propane/LP gas supply may be low (pro - pane/LP only) Yo u m ay fe el you r gas pres sur e is ...
-
FMI VMH26TPC - page 29
www .fmiproducts.com 1 131 1 1-01 29 ACCESSORIES THERMOST A TICALL Y - CON- Provides better heat distribu - tion. Makes replace more efcient. Automati - cally turns off and on as needed. CORNER MANTEL WITH FULL ...
-
FMI VMH26TPC - page 30
www .fmiproducts.com 1 131 1 1-01K 30 P ARTS 23 29 40 32 36 38 13 7 8 33 40 1 1 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12-1 14 25 14 40 3 37 26 39 39 5 6 9 ...
-
FMI VMH26TPC - page 31
www .fmiproducts.com 1 131 1 1-01 31 P ARTS This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual. 1 102633-02 Outer Casing T op • • 1 2 102624 ...
-
FMI VMH26TPC - page 32
1 131 1 1-01 Rev . K 05/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES Standard Warranty: FM I PR O DU CT S, LL C wa rr an ts t hi s ne w p r od uc t an d a ny pa rt s t he re of to be fr ee f ro m de fe ct s i n ma te ri a l a nd w or km an sh ip f or a pe ri od o f f ou r ( 4) y ea rs f r ...
Do you have a question concerning FMI VMH26TPC?
Use the form below
If you did not solve your problem by using a manual FMI VMH26TPC, ask a question using the form below. If a user had a similar problem with FMI VMH26TPC it is likely that he will want to share the way to solve it.