Manual Chauvet DMX5M

20 pages 0.87 mb
Download

Go to site of 20

Summary
  • Chauvet DMX5M - page 1

    3000 N 29 th Ct, Holl ywood, FL 33020 U.S. A. (800 ) 762-10 84 – (954) 929-1115 FA X (954) 929 -5560 www.chauvetlighting.c om USER MANUAL Snapshot OK on Dimm er Outdoor OK Sound Activa ted DMX512 Master/Sl ave Autoswitching Transf ormer Repl aceab le F u se User Service ab le Duty Cycle ...

  • Chauvet DMX5M - page 2

    Scorpion™ S t o r m RGX Us e r Manu al 2 4/27/2009 5:13 PM T ABLE OF C ONTENTS 1. Befor e You Beg in ................................................................................................................................ 3 W h at is i n clude d .............................................................................................. ...

  • Chauvet DMX5M - page 3

    Scorpion™ S t o r m RGX Us e r Manu al 3 4/27/2009 5:13 PM 1. B EFORE Y OU B EGIN What is included  1 x Sc o r pion™ St orm RG X  1 x Power C ord  1 x W a rr anty Card  1 x Us e r Manu al Unpacking Instructions Immediat ely upon rec eiving a fixture, c are f ully unpack th e c a rt on, che ck the c ontents t o ensur e that all parts ...

  • Chauvet DMX5M - page 4

    Scorpion™ S t o r m RGX Us e r Manu al 4 4/27/2009 5:13 PM Safety Instructions Plea s e keep this Us er Guid e for futur e consu ltation. If you sell t he unit t o another us er, b e sure that they als o receive th is instructi on booklet. Always make sur e that you are connecti ng t o th e pr ope r voltage, and th at the line voltag e you are co ...

  • Chauvet DMX5M - page 5

    Scorpion™ S t o r m RGX Us e r Manu al 5 4/27/2009 5:13 PM NON -IN T ERLOCKE D HOUSING W A RNING This unit c ontains h igh pow er las e r d evices i nternally. D o not op en the laser housing, due t o p otenti al exposure t o uns a f e levels of l a s er rad iation. Th e las e r power l evels acc e ss ible if t he unit i s open ed can caus e inst ...

  • Chauvet DMX5M - page 6

    Scorpion™ S t o r m RGX Us e r Manu al 6 4/27/2009 5:13 PM LASER SAFET Y L ABEL REPRO DUCTION LASER HA ZA RD W ARNING LAB EL LASER APERTURE LABEL EXP LAN ATORY, MANU FACTURER’S ID & CERTIFICATION LABEL NON INTERLOCKED HOUSING LABE L ...

  • Chauvet DMX5M - page 7

    Scorpion™ S t o r m RGX Us e r Manu al 7 4/27/2009 5:13 PM LA SER LIGHT AV OID DIREC T EYE EXPOSURE Further gui delin e s and s a f e t y pr ograms f or safe us e of lasers c an be found in th e ANSI Z136.1 Stan dard “ For S a f e Use o f Lasers”, availabl e fr om the Laser Inst itute o f Am e r ic a : w ww.laseri nstit ute.org. Many loc al g ...

  • Chauvet DMX5M - page 8

    Scorpion™ S t o r m RGX Us e r Manu al 8 4/27/2009 5:13 PM 2. I NTRODUCTIO N Features 4-channel DM X-5 12 c o ntr olled r ed and green eff ect laser Eff e ct m otor with c ontr o l of rot a ti on and st utter eff ect C o lor s election o f red, gr een or bot h red & g reen wit h s trob e control Built-in automat ic pr ograms via m a st er/sla ...

  • Chauvet DMX5M - page 9

    Scorpion™ S t o r m RGX Us e r Manu al 9 4/27/2009 5:13 PM Product O v er view Power LED H a ngi ng bracket Bracket adjustm ent knob (1 of 2) Audio LED Laser Apert ure ...

  • Chauvet DMX5M - page 10

    Scorpion™ S t o r m RGX Us e r Manu al 10 4 /27/2009 5:13 PM P RODUCT D IMENSI ONS ...

  • Chauvet DMX5M - page 11

    Scorpion™ S t o r m RGX Us e r Manu al 11 4 /27/2009 5:13 PM P ROPER U SAGE CAU TION: Us e of c ontrols , adju stmen ts, or perfo rmance of procedu res o ther than wh at is sp ecifi ed here in may resu lt in haz ardous rad iat ion exposu re 3 meters CAUTI ON : Use of controls, adju stments, or performan ce of procedures other than what is specifi ...

  • Chauvet DMX5M - page 12

    Scorpion™ S t o r m RGX Us e r Manu al 12 4 /27/2009 5:13 PM Th e fus e is locat ed inside this compartm ent. R e mo ve using a f lat head scr ewdriver. Han g ing Clamp Note! Clam p is sold s eparately . 3. S ETUP Fuse Replacement W ith a flat head sc rewdriver wed ge th e fus e holder out of its h ousing. Remo ve th e damag ed fuse fr om its hol ...

  • Chauvet DMX5M - page 13

    Scorpion™ S t o r m RGX Us e r Manu al 13 4 /27/2009 5:13 PM Fixture Linking You wi ll need a s erial d ata link t o run light s hows of one or m o r e fi xtures using a D MX - 512 c ontroll e r or to run s ynchr onized shows on two or more fi xtures s e t to a mas ter/ slave oper ating mod e. The combined n umber o f chann els r equired b y all ...

  • Chauvet DMX5M - page 14

    Scorpion™ S t o r m RGX Us e r Manu al 14 4 /27/2009 5:13 PM Th is drawing provid es a gen eral illu stration of the DMX I nput/ Output p anel of a ligh ting fixture. Universal D MX C ontroller Continue the link Often, the setup for M as te r-Sl ave and Standalone oper ation requires that the first fixture in the chain be initialized for this pur ...

  • Chauvet DMX5M - page 15

    Scorpion™ S t o r m RGX Us e r Manu al 15 4 /27/2009 5:13 PM 4. O PERA TING I N ST RUCTIO NS Na vigating the Control Panel Access c ontrol p anel functions using th e f o ur p anel b uttons lo c ated di r e ctl y undern eath th e LE D Display. The C ontrol Pan el LED Dis play sh ow s the menu items you sel e ct fr om th e menu map on page # . W h ...

  • Chauvet DMX5M - page 16

    Scorpion™ S t o r m RGX Us e r Manu al 16 4 /27/2009 5:13 PM DMX Channel Values C HANNEL V ALUE F UNCTI ON 1 000  0 19 020  0 39 040  0 59 060  0 79 080  0 99 100  1 19 120  1 39 140  1 59 160  1 79 180  1 99 200  2 55 Control M ode DMX Mo de Automatic fast (r ed) Automatic slow (r ed) Automatic fast (green) Autom ...

  • Chauvet DMX5M - page 17

    Scorpion™ S t o r m RGX Us e r Manu al 17 4 /27/2009 5:13 PM S E T T I N G T H E S T A R T I N G A D D R E S S This DMX m ode enab les th e use o f a uni versal DM X c o n troller de vice. Eac h fixtur e requir es a "st a rt address " from 1 t o 512. A fi xtur e req uiring on e or m o r e ch ann els f o r c ontrol b egin s t o r ead the ...

  • Chauvet DMX5M - page 18

    Scorpion™ S t o r m RGX Us e r Manu al 18 4 /27/2009 5:13 PM Technical Support Address: S ervic e D ept. 3000 N 29t h Ct, H ollywood, F L 33020 (U. S.A.) Support (E mail): t ech@ch auvetlighti ng.com Telephon e: (954) 92 9-111 5 - (Pr e ss 4) Fax: (954) 929-556 0 - (Atten tion: S ervic e ) W e bsite: h ttp://www.c hauvetli ghting.c om 5. A PPENDI ...

  • Chauvet DMX5M - page 19

    Scorpion™ S t o r m RGX Us e r Manu al 19 4 /27/2009 5:13 PM Claims D a mage incurr ed in shippi ng is th e r e sp onsibility of the sh ipper; th eref o r e the damage must be reported t o the c a rr ier up on re c eipt o f m erchandis e. It is th e cust omer's r esponsibility t o notif y and submit claims with the sh ipp er in th e event th ...

  • Chauvet DMX5M - page 20

    Scorpion™ S t o r m RGX Us e r Manu al 20 4 /27/2009 5:13 PM Technical Specifications WEIGHT & DIMEN SIONS Length ................................................................................................................................ . 11 in (2 76 mm ) W idth ........................................................................... ...

Manufacturer Chauvet Category Projector

Documents that we receive from a manufacturer of a Chauvet DMX5M can be divided into several groups. They are, among others:
- Chauvet technical drawings
- DMX5M manuals
- Chauvet product data sheets
- information booklets
- or energy labels Chauvet DMX5M
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chauvet DMX5M.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chauvet DMX5M, service manual, brief instructions and user manuals Chauvet DMX5M. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chauvet DMX5M.

Similar manuals

A complete manual for the device Chauvet DMX5M, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chauvet DMX5M by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chauvet DMX5M.

A complete Chauvet manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chauvet DMX5M - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chauvet DMX5M, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chauvet DMX5M, that we can find in the current document
3. Tips how to use the basic functions of the device Chauvet DMX5M - which should help us in our first steps of using Chauvet DMX5M
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chauvet DMX5M
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chauvet DMX5M in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chauvet DMX5M?

Use the form below

If you did not solve your problem by using a manual Chauvet DMX5M, ask a question using the form below. If a user had a similar problem with Chauvet DMX5M it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)