    ii C O N T E N T S PAGE I. SPECIFICATIONS --------------------------------------------------------------------------------------- 1 1. SPECIFICATIONS----------------------------------------------------------------------------------- 1 [a] KMD-410MAH (air-cool ed) --------------------------------------------------------------------- 1 [b] KMD-410MWH ...

  • Hoshizaki KMD-410MAH - page 4

    iii 1. 10-MINUTE DIAGNOSTIC PROCEDURE ----------------------------------------------------- 27 2. DIAGNOSTIC CHARTS----------------------------------------------------------------------------- 29 [a] NO ICE PR ODUCTION ------------------------------------------------------------------------ 29 [b] EVAPORATOR IS FROZEN UP --------------------------- ...

  • Hoshizaki KMD-410MAH - page 5

    1 AC SUPPLY VOLTAGE 115/60/1 㩷 AMPERAGE 8.0 A (5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day (kg/day) 70 *415 (188) 388 (176) 354 (160) Reference without *marks 80 395 (179) 353 (160) 320 (145) 90 388 (176) *324 ...

  • Hoshizaki KMD-410MAH - page 6

    2 [b] KMD-410MWH (water-cooled) AC SUPPLY VOLTAGE 115/60/1 㩷 AMPERAGE 6.5 A (5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day (kg/day) 70 *440 (200) 423 (192) 392 (178) Reference without *marks 80 427 (194) 401 (182 ...

  • Hoshizaki KMD-410MAH - page 7

    3 II. GENERAL INFORMATION 1. CONSTRUCTION [a] KMD-410MAH Spray Guide Spray Tube Drain Valve Water Supply Inlet Water Tank Cube Guide Pump Motor Float Switch Condenser Fan Motor Hot Gas Valve Compressor Control Box Expansion Valve Harvest Water Valve Fill Water Valve Control Switch Service Switch Fuse Holder (Fuse) Bin Control Switch Drier Thermisto ...

  • Hoshizaki KMD-410MAH - page 8

    4 [b] KMD-410MWH Spray Guide Spray Tube Drain Valve Water Supply Inlet Water Tank Cube Guide Pump Motor Float Switch Water Regulator Condenser Hot Gas Valve Compressor Control Box Expansion Valve Harvest Water Valve Fill Water Valve Control Switch Service Switch Fuse Holder (Fuse) Bin Control Switch Drier Thermistor Access Valve (Low Side) Access V ...

  • Hoshizaki KMD-410MAH - page 9

    5 2. SEQUENCE OF OPERATION The steps in the sequence are as outlined below. When power is supplied, a 5 second delay occurs at startup. Note that the order of the LEDs from the outer edge of the board is 5, 6, 8, 9, 4, 7. [a] ONE MINUTE FILL CYCLE LED 8 is on. HWV opens and the fill period begins. After 1 minute, the board checks for a closed LF/S. ...

  • Hoshizaki KMD-410MAH - page 10

    6 [e] NORMAL HARVEST CYCLE LEDs 5, 6, and 8 are on. Comp continues to run, HGV remains open and HWV opens. As the evaporator warms, the thermistor reaches 9ºC. The control board then receives the thermistor’s 3.9k signal and starts the harvest timer. HWV is open during harvest for a maximum of 6 minutes or the length harvest minus 0, 10, 30, ...

  • Hoshizaki KMD-410MAH - page 11

    7 KMD-410MAH, 410MWH “H” board will have 5 second delay x Maximum harvest water valve time: 6 minutes (HWV time is 6 minutes of the length of harvest minus 0, 10, 30, or 50 sec. (S1 dip switch 7 & 8), whichever is shorter. PM energizes and runs for the last 0, 10, 30, or 50 sec. of harvest.) x Maximum harvest time: 20 minutes x Minimum free ...

  • Hoshizaki KMD-410MAH - page 12

    8 3. CONTROL BOARD * A HOSHIZAKI exclusive solid-state control is employed in KMD-410MAH and KMD-410MWH Crescent Cubers. * All models are pretested and factory-adjusted. 1. Fragile, handle very carefully. 2. A control board contains integrated circuits, which are susceptible to failure due to static discharge. It is especially important to touch th ...

  • Hoshizaki KMD-410MAH - page 13

    9 [a] CONTROL BOARD LAYOUT #4 Harvest Water Valve #5 Freeze Water Valve #1, 2, 3 Float Switch Control Board Auxiliary Code V1 or Earlier V2 or Later Part Number P00013-02 P01771-02 T ype HKM2006V003 ...

  • Hoshizaki KMD-410MAH - page 14

    10 [b] FEATURES a) Maximum Water Supply Period - 6 minutes The harvest water valve will be open during harvest for 6 minutes or the length of harvest minus 0, 10, 30, or 50 seconds (adjustable by S dip switch 7 & 8), whichever is shorter. b) Harvest Backup Timer and Freeze Timer The harvest backup timer shuts down the icemaker if, for two cycle ...

  • Hoshizaki KMD-410MAH - page 15

    11 f) LED Lights and Audible Alarm Safeties The control board includes LED indicator lights, audible alarm safeties, and an output test feature. The "POWER OK" LED indicates control voltage and will remain on unless a control voltage problem occurs. The “POWER OK” LED flashes continuously when the bin is full and DV energizes for a ma ...

  • Hoshizaki KMD-410MAH - page 16

    12 [c] CONTROLS AND ADJUSTMENTS a) Default Dip Switch Settings The dip switch is factory-adjusted to the following positions: S1 Dip Switch No. 1 2 3 4 5 6 7 8 9 10 KMD-410MAH OFF OFF OFF OFF ON ON ON ON OFF OFF KMD-410MWH OFF OFF OFF OFF ON ON ON ON ON OFF S2 Dip Switch * Functions of S2 dip switch nos. 2 through 6 depend on program ve rsion. Do n ...

  • Hoshizaki KMD-410MAH - page 17

    13 c) Drain Timer (S1 dip switch 3 & 4) Once every ten freeze cycles, the drain valve opens to drain the water tank for the time determined by the drain timer. These switches also determine the time to delay completion of a defrost cycle, i.e. the minimum defrost time. Do not change this setting, or the unit will not operate properly or produce ...

  • Hoshizaki KMD-410MAH - page 18

    14 f) Freeze Timer (S1 dip switch 9 & 10) The freeze timer setting determines the maximum allowed freeze time to prevent possible freeze-up issues. Upon termination of freeze timer, machine initiates the harvest cycle. After 2 consecutive timer terminations, machine will shut down, possibly indicating a problem. The freeze timer is factory adju ...

  • Hoshizaki KMD-410MAH - page 19

    15 S2 Dip Switch Setting No. 6 Anti-Slush Control OFF Activated (V er . 1.0) ON Deactivated Control Board P01771-02 k) Harvest Promotion Control (S2 dip switch 2) [Program Ver. 3.1, Ver. 3.2] Do not adjust. This must be left in the factory default position or the unit will not operate properly. It is deactivated on the KMD-410 series. When activate ...

  • Hoshizaki KMD-410MAH - page 20

    16 temperature at the end of a harvest cycle is 4K or more and if the temperature at the end of a harvest cycle is 48°F (9°C) or less, the harvest cycle is extended for 30 seconds. If the difference between the temperature at the beginning of a freeze cycle and the minimum temperature after 30 seconds in the freeze cycle is 2.5K or more and less ...

  • Hoshizaki KMD-410MAH - page 21

    17 [d] CONTROL BOARD CHECK PROCEDURE Before replacing a control board that does not show a visible defect and that you suspect is bad, always conduct the following check procedure. This procedure will help you verify your diagnosis. 1) Check the dip switch settings to assure that S1 dip switch 3, 4, 7, 8, 9, & 10 and S2 dip switch 1 through 6 a ...

  • Hoshizaki KMD-410MAH - page 22

    18 4. HARVEST CONTROL – THERMISTOR A thermistor (semiconductor) is used as a harvest control sensor, anti-slush sensor, and overfreeze sensor. The resistance varies depending on the suction line temperatures. The thermistor detects the temperature of the evaporator outlet to start the harvest timer or momentarily stop the pump motor during the fr ...

  • Hoshizaki KMD-410MAH - page 23

    19 5. FLOAT SWITCH [a] EXPLANATION OF OPERATION The float operates 2 switches within the float switch. The lower switch (black and blue wires) is used for low water safety protection, initiating the freeze cycle refill and terminating the freeze cycle. The upper switch (black and red wires) is used to terminate the freeze cycle refill only. Refill ...

  • Hoshizaki KMD-410MAH - page 24

    20 6. BIN CONTROL This machine uses a lever-actuated proximity switch (mechanical bin control) to control the ice level in the storage bin. No adjustment is required. [a] EXPLANATION OF OPERATION The bin control is connected to the K1 connector (pins 4 & 5) on the control board. When the bin control is calling for ice (proximity switch closed; ...

  • Hoshizaki KMD-410MAH - page 25

    21 7. SWITCHES Two different control switches are used for operation of KMD-410MAH and KMD-410MWH. These switches are referred to as the "control switch" and the "service switch" and are located on the control box. [a] CONTROL SWITCH This switch is used to place the machine into one of three modes: “OFF” (center position), ? ...

  • Hoshizaki KMD-410MAH - page 26

    22 III. TECHNICAL INFORMATION 1. WATER CIRCUIT AND REFRIGERANT CIRCUIT ...

  • Hoshizaki KMD-410MAH - page 27

    23 2. WIRING DIAGRAM * The magnetic cont actor wiring depends on the contactor model. 428393-01 VC20-1a1b 449000-01 G7L-1A-TUB See above 449000-01 only ...

  • Hoshizaki KMD-410MAH - page 28

    24 3. TIMING CHART 9°C 5°C ~Program Ver3.1 THERMISTO R COMPRESSO R ON OFF ON HARVES T CYCLE (AFTER BIN FULL) HARVEST CYCLE POWER SWITCH FREEZE CY CLE FREEZE CY CLE HARVEST CYCLE (INITIAL) ON OFF PART NAME HARVEST CYCLE HARVEST C YCLE (INCLUDING DR AIN) BIN FULL OFF Program Ver3.2 FAN MOTOR ON OFF ON PUMP MOTO R HOT G AS VALVE ON OFF HARVEST WATER ...

  • Hoshizaki KMD-410MAH - page 29

    25 4. PERFORMANCE DATA [a] KMD-410MAH WATER TEMP. (ºF/ºC) AMBIENT TEMP. (ºF/ºC) 50/10 70/21 90/32 70/21 415 188 388 176 354 160 80/27 395 179 353 160 320 145 APPROXIMATE ICE PRODUCTION PER 24 HR. 90/32 388 176 324 147 289 131 lbs./day kg./day 100/38 382 173 316 143 257 117 70/21 710 731 753 80/27 726 758 776 APPROXIMATE ELECTRIC CONSUMPTION 90/ ...

  • Hoshizaki KMD-410MAH - page 30

    26 [b] KMD-410MWH WATER TEMP. (ºF/ºC) AMBIENT TEMP. (ºF/ºC) 50/10 70/21 90/32 70/21 440 200 423 192 392 178 80/27 427 194 401 182 364 165 APPROXIMATE ICE PRODUCTION PER 24 HR. 90/32 423 192 382 173 347 157 lbs./day kg./day 100/38 414 188 373 169 315 143 70/21 670 673 682 80/27 672 677 688 APPROXIMATE ELECTRIC CONSUMPTION 90/32 673 680 690 watts ...

  • Hoshizaki KMD-410MAH - page 31

    27 IV. SERVICE DIAGNOSIS 1. 10-MINUTE DIAGNOSTIC PROCEDURE The 10 minute check out procedure is basically a sequence check which c an be used  at unit start-up or for system diagnosis. Using this check out procedure will allow you  to diagnose electrical system and component failures in approximately 10 minutes  under normal operating cond ...

  • Hoshizaki KMD-410MAH - page 32

    28 a. Lower Float Switch 1st Activation: Refill – The refill can occur at any time during the freeze cycle (1 refill per cycle). As ice builds the water level drops in the reservoir and the lower float switch activates (opens). LED 5 comes on and the control board energizes the fill water valve. The fill water valve remains energized until the up ...

  • Hoshizaki KMD-410MAH - page 33

    29 2. DIAGNOSTIC CHARTS [a] NO ICE PRODUCTION 2. See "II. 6. [b] Bin Control Check Procedur e." 5. See chart [a] [7]. ...

  • Hoshizaki KMD-410MAH - page 34

    30 1. See "II. 4. Harvest Control - Thermistor." 1. See "II. 3. [d] Control Board Check Procedure." 1. See "II. 3. [d] Control Board Check Procedure." ...

  • Hoshizaki KMD-410MAH - page 35

    31 1. See "II. 3. [d] Control Board Check Procedure." 1. See "II. 3. [d] Control Board Check Procedure." 1. See "II. 3. [d] Control Board Check Procedure." 1. See "II. 3. [d] Control Board Check Procedure." 1. See "II. 3. [d] Control Board Check Procedure." ...

  • Hoshizaki KMD-410MAH - page 36

    32 [b] EVAPORATOR IS FROZEN UP 1. Adjust or replace. See "V. 9. Adjustment of Water Re g ulatin g Valve ." 1. See "V. 17. Thermistor." 1. See "II. 3. [c] Controls and Adjustments, b) Harvest Timer." 1. See "II. 3. [d] Control Board Check Procedure." ...

  • Hoshizaki KMD-410MAH - page 37

    33 [c] LOW ICE PRODUCTION [d] ABNORMAL ICE a) See chart [b] [1] and check float switch, fill and harvest water valves, control board, water pump, spray tubes, evaporator, and expansi on valve. b) See chart [a] [1] and check dirty air filter or con denser, ambient or water temperature, refrigerant charge, water p ressure, and condenser water regulat ...

  • Hoshizaki KMD-410MAH - page 38

    34 [e] OTHER a) See chart [b] [1] & [3] and check float switch, fill and harvest water valves, control board, spray tubes, water system, refrigerant charge, and expansion valve. 1. See "II. 6. [b] Bin Control Check Procedur e." c) Ice Cube Guide, Water Tank, Deflector ...

  • Hoshizaki KMD-410MAH - page 39

    35 V. REMOVAL AND REPLACEMENT 1. SERVICE FOR REFRIGERANT LINES [a] SERVICE INFORMATION 1) Allowable Compressor Opening Time and Prevention of Lubricant Mixture [R404A] The compressor must not be opened more than 15 minutes in replacement or service. Do not mix lubricants of different compressors even if both are charged with the same refrigerant, e ...

  • Hoshizaki KMD-410MAH - page 40

    36 7) Evacuation, Vacuum Pump and Refrigerant Charge [R404A] Never allow the oil in the vacuum pump to flow backward. The vacuum level and vacuum pump may be the same as those for the current refrigerants. However, the rubber hose and gauge manifold to be used for evacuation and refrigerant charge should be exclusively for R404A. 8) Refrigerant Lea ...

  • Hoshizaki KMD-410MAH - page 41

    37 2. BRAZING Note: All brazing connections inside the bin are clear coated. Sandpaper the brazing connections before unbrazing the components. Use a good abrasive cloth to remove the coating. 3. COMPRESSOR 1) Turn off the power supply. 2) Remove the panels and water tank. See "V. 14. WATER TANK." ...

  • Hoshizaki KMD-410MAH - page 42

    38 3) Recover the refrigerant and store it in an approved container. 4) Remove the terminal cover on the compressor and disconnect the compressor wiring. 5) Remove the hold-down bolts, washers, and rubber grommets. 6) Remove the discharge and suction pipes. 7) Remove the compressor. Unpack the new compressor package. 8) Attach the rubber grommets o ...

  • Hoshizaki KMD-410MAH - page 43

    39 5) Remove the drier using brazing equipment. 6) Braze the new drier, with the arrow on the drier in the direction of the refrigerant flow. Use nitrogen gas at a pressure of 20 to 30 kPa when brazing tubings. Braze in an access valve using a tee if necessary. 7) Check for leaks using nitrogen gas (970 kPa) and soap bubbles. 8) Evacuate the system ...

  • Hoshizaki KMD-410MAH - page 44

    40 8) Install the new drier (see "V. 4. DRIER"). 9) Check for leaks using nitrogen gas (970 kPa) and soap bubbles. 10) Evacuate the system and charge it with refrigerant (see "V. 1. [c] EVACUATION AND RECHARGE"). 11) Attach the solenoid coil to the valve body, and secure it with the screw. 12) Connect the lead wires. 13) Refit t ...

  • Hoshizaki KMD-410MAH - page 45

    41 9) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the nameplate for the required refrigerant charge. 10) Attach the expansion valve bulb to the suction line in the same location as the previous bulb. The bulb should be at the 12 o'clock posit ion on the tube. Be sure to secure the bulb with ...

  • Hoshizaki KMD-410MAH - page 46

    42 14) Turn on the power supply. 8. WATER REGULATING VALVE – WATER-COOLED MODEL ONLY 1) Turn off the power supply. 2) Remove the panels. 3) Close the condenser water supply line shut-off valve, then open the condenser water supply line drain valve. 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve. ...

  • Hoshizaki KMD-410MAH - page 47

    43 17) Check for water leaks. 18) Replace the panels in their correct positions. 19) Turn on the power supply. 9. ADJUSTMENT OF WATER REGULATING VALVE – WATER-COOLED MODEL ONLY The water regulating valve (also called "water regulator") is factory-adjusted. No adjustment is required under normal use. Adjust the water regulator, if necess ...

  • Hoshizaki KMD-410MAH - page 48

    44 7) Replace the panels in their correct positions. 8) Turn on the power supply. 11. PUMP MOTOR 1) Turn off the power supply. 2) Remove the panels and front insulation. 3) Disconnect the connector of the pump motor lead. 4) Remove the thumbscrew securing the pump motor. 5) Remove the hose band connecting the discharge hose. 6) Slide the pump motor ...

  • Hoshizaki KMD-410MAH - page 49

    45 7) Remove the hose band connecting the discharge outlet and pull off the rubber hose. 8) Install the new motor in the reverse order of the removal procedure. 9) Replace the panels and front insulation in their correct positions. 10) Turn on the power supply. 12. WATER VALVE 1) Turn off the power supply. 2) If replacing the harvest and/or fill wa ...

  • Hoshizaki KMD-410MAH - page 50

    46 7) Remove the two mounting screws. 8) Install the new valve in the reverse order of the removal procedure. 9) Open the water supply tap. 10) Plug in the icemaker or connect the power source. 11) Check for leaks. 12) Refit the panels in their correct positions. 14. WATER TANK 1) Remove the front panel, then remove the front insulation 2) Loosen t ...

  • Hoshizaki KMD-410MAH - page 51

    47 10) Install the new water tank in the reverse order of the removal procedure. 11) Refit the panels in their correct positions. 12) Turn on the power supply. 15. FLOAT SWITCH 1) Remove the pump motor bracket. See "V. 14. WATER TANK." 2) Pull up the pump motor bracket from the water tank. 3) Flip over the pump motor bracket assembly, the ...

  • Hoshizaki KMD-410MAH - page 52

    48 4) Install the new float switch in the reverse order of the removal procedure. 5) Refit the panels in their correct positions. 6) Turn on the power supply. 16. BIN CONTROL SWITCH 1) Remove the water tank. See "V. 14. WATER TANK." 2) Disconnect the connector of the bin control switch lead (black). 3) Pull out the bin control switch tab ...

  • Hoshizaki KMD-410MAH - page 53

    49 8) Connect the bin control connector to the side of the control box. 9) Replace the water tank, cube guide, pump motor bracket, pump motor and float switch in their correct positions until they snap in place. CAUTION Be sure to let the discharge hose pass behind the copper tube and connect it securely in position. Otherwise, the discharge hose m ...

  • Hoshizaki KMD-410MAH - page 54

    50 8) Attach the new thermistor in position on the suction pipe and press down the thermistor holder over the thermistor. Be careful not to damage the thermistor lead. Cover the parts with the insulation and secure them with the ties. Keep the thermistor inside the thermistor holder. After the thermistor holder is fitted, do not pull the thermistor ...

  • Hoshizaki KMD-410MAH - page 55

    51 Note: After replacing the components inside the control box, connect and tie the wires properly in their correct position. Especially make sure that the harness does not press the push buttons on the control board. Control Box Cover Control Box Screw Screws Controller Board Control Switch Service Switch Fuse Fuse Holder Starter Transformer Capac ...

  • Hoshizaki KMD-410MAH - page 56

    52 [a] CONTROL & SERVICE SWITCH 1) Disconnect the tab terminals and remove the nut securing the power switch. 2) Install the new switch in the reverse order of the removal procedure. 3) To prevent miswiring, check the terminal numbers and lead wire colors with the wiring label. [b] FUSE 1) Use a phillips head screwdriver to remove the fuse hold ...

  • Hoshizaki KMD-410MAH - page 57

    53 [g] STARTER 1) Disconnect the terminals, remove the mounting screw. 2) Install the new starter in the reverse order of the removal procedure. 3) To prevent miswiring, check the terminal numbers and lead wire colors with the wiring label. [h] RUN CAPACITOR 1) Disconnect the terminals on the starter and remove the nut securing the run capacitor. 2 ...

  • Hoshizaki KMD-410MAH - page 58

    54 6) The spray tube is easily cleanable by removing the black rubber caps on the ends. 7) Remove the hose band connecting the water supply tube. 8) Pull the water supply tube towards you. 9) Remove the top insulation. 10) The spray guide is located under the water supply tube. Pull off the spray guide from the evaporator. 11) Refit the removed par ...

  • Hoshizaki KMD-410MAH - page 59

    55 VI. CLEANING AND MAINTENANCE INSTRUCTIONS 1. CLEANING [a] CLEANING PROCEDURE 1) Dilute approximately 9.5 fl. oz. (281 ml) of recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 1.8 gallon (6.8 lit.) of water. 2) Remove all ice from the evaporator and the storage bin/dispenser unit. Note: To remove ...

  • Hoshizaki KMD-410MAH - page 60

    56 7) Remove the front panel then remove the front insulation (the large insulation panel in front of the evaporator) by lifting up the panel slightly and pulling it towards you. 8) In bad or severe water conditions, clean the float switch as described below. Otherwise, continue to step 9. a. Loosen the two thumbscrews securing the pump motor brack ...

  • Hoshizaki KMD-410MAH - page 61

    57 g. Wipe down the float switch housing, shaft and float with cleaning solution. Rinse the parts thoroughly with clean water. h. Replace the float switch in its correct position. i. Replace the removed parts in the reverse order of which they were removed. 9) Pour the cleaning solution into the water tank. 10) Move the service switch to the " ...

  • Hoshizaki KMD-410MAH - page 62

    58 31) Remove the front panel. 32) Repeat steps 18 through 31 three more times to rinse thoroughly. Note: If you do not sanitize the icemaker, go to step 14 in "Sanitizing Procedure." [b] SANITIZING PROCEDURE – FOLLOWING CLEANING PROCEDURE 1) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with water (add approximately 0.9 ...

  • Hoshizaki KMD-410MAH - page 63

    59 [a] STAINLESS STEEL EXTERIOR To prevent corrosion, wipe the exterior occasionally with a clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up. [b] STORAGE BIN AND SCOOP * Wash your hands before removing ice. Use the plastic scoop provided (bin accessory). * The storage bin/dispenser unit is for ice us ...

  • Hoshizaki KMD-410MAH - page 64

    60 2) Move the control switch on the control box to the "OFF" position. 3) Wait 3 minutes. 4) Move the control switch to the "ICE" position. 5) Replace the front panel in its correct position and turn on the power supply. 6) Allow 5 minutes for the icemaker to fill with water and the water pump to start operating. 7) Close the c ...

  • Hoshizaki KMD-410MAH - page 65

    61 4) Turn off the power supply and remove the front panel. 5) Move the control switch to the "OFF" position. 6) Replace the front panel in its correct position. 7) Remove all ice from the storage bin/dispenser unit, and clean the storage bin/dispenser unit. 8) Close the icemaker water supply line drain valve. ...

Manufacturer Hoshizaki Category Ice Maker

Documents that we receive from a manufacturer of a Hoshizaki KMD-410MAH can be divided into several groups. They are, among others:
- Hoshizaki technical drawings
- KMD-410MAH manuals
- Hoshizaki product data sheets
- information booklets
- or energy labels Hoshizaki KMD-410MAH
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hoshizaki KMD-410MAH.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hoshizaki KMD-410MAH, service manual, brief instructions and user manuals Hoshizaki KMD-410MAH. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hoshizaki KMD-410MAH.

A complete manual for the device Hoshizaki KMD-410MAH, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hoshizaki KMD-410MAH by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hoshizaki KMD-410MAH.

A complete Hoshizaki manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hoshizaki KMD-410MAH - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hoshizaki KMD-410MAH, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hoshizaki KMD-410MAH, that we can find in the current document
3. Tips how to use the basic functions of the device Hoshizaki KMD-410MAH - which should help us in our first steps of using Hoshizaki KMD-410MAH
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hoshizaki KMD-410MAH
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hoshizaki KMD-410MAH in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hoshizaki KMD-410MAH?

Use the form below

If you did not solve your problem by using a manual Hoshizaki KMD-410MAH, ask a question using the form below. If a user had a similar problem with Hoshizaki KMD-410MAH it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)