Manual Desa BY35CEB

24 pages 0.63 mb
Download

Go to site of 24

Summary
  • Desa BY35CEB - page 1

    IMPORTANT: Read and understand this manual before assembling, start- ing or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. R POR T ABLE FORCED AIR HEA TERS OWNER’S MANUAL Heater Sizes: 35,000 70,000 100,000 150,000 Btu/Hr Models: BY35CEB, BY70CEB, BY100CEB, and BY150CEB ...

  • Desa BY35CEB - page 2

    2 103618 POR T ABLE FORCED AIR HEA TERS R Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These ...

  • Desa BY35CEB - page 3

    3 103618 OWNER’S MANUAL PRODUCT IDENTIFICA TION Side Cover Lower Shell Fuel Cap Hot Air Outlet Upper Shell Flame-Out Control Reset Button Power Cord Figure 2 - 100/150,000 Btu/Hr Models Fuel Tank Fan Guard Lower Shell Side Cover Fuel Tank Upper Shell Hot Air Outlet Handle Fan Guard Air Filter End Cover Fuel Cap Figure 1 - 35/70,000 Btu/Hr Models ...

  • Desa BY35CEB - page 4

    4 103618 POR T ABLE FORCED AIR HEA TERS R FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter and nozzle • carbon build up on spark plug • use of non-toxic anti-icer in fuel during very cold weather IMPORTANT: Use a KEROSENE ONLY container. Be sure storage container is ...

  • Desa BY35CEB - page 5

    5 103618 OWNER’S MANUAL Electronic Ignitor Fan Fuel Filter Air For Fuel System Air For Combustion And Heating Fuel Spark Plug Combustion Chamber Intake Air Filter Motor Air Pump Air Line To Burner Burner Head Clean Heated Air Out Cool Air In Output Air Filter Nozzle Fuel Tank THEOR Y OF OPERA TION The Fuel System: The air pump forces air through ...

  • Desa BY35CEB - page 6

    6 103618 POR T ABLE FORCED AIR HEA TERS R STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- quire fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap open- ing. ...

  • Desa BY35CEB - page 7

    7 103618 OWNER’S MANUAL TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. See Pump Pressur e Adjustment , pa ge 10. 2. See Air Output, Air Intake and Lint F il- ters , page 10. 3. See Fuel F ilter , page 8. 4. See Nozzle , page 11. 5. Clean photocell len ...

  • Desa BY35CEB - page 8

    8 103618 POR T ABLE FORCED AIR HEA TERS R Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models Upper Shell Removal 1. Remove screws and lock washers along each side of heater using 5/16" nut- driv er . These scre ws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. Fuel Filter (35/70,000 Btu/Hr Models) 1 ...

  • Desa BY35CEB - page 9

    9 103618 OWNER’S MANUAL Spark Plug (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly . 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut- driver and remove burner strap. 6. Place hex-body of spark plug into vise and tight ...

  • Desa BY35CEB - page 10

    10 103618 POR T ABLE FORCED AIR HEA TERS R Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-dri ver . 3. Remov e filter end cover . 4. Replace air output and lint filters. 5. W ash or replace air intake filter (see Pr eventative Maintenance Sc hedule, page 6). 6. ...

  • Desa BY35CEB - page 11

    11 103618 OWNER’S MANUAL Nozzle (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly . 4. T urn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6 . Carefully remove nozzle from the noz ...

  • Desa BY35CEB - page 12

    12 103618 POR T ABLE FORCED AIR HEA TERS R Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-dri ver . 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-dri ver . 5. Remove pump plate. 6. Remov e rotor, insert, and blade ...

  • Desa BY35CEB - page 13

    13 103618 OWNER’S MANUAL Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 8). 2. Use 1/8" allen wrench to loosen set- screw which holds fan to motor shaft. 3. Slip fan of f motor shaft. 4. Clean fan using a soft ...

  • Desa BY35CEB - page 14

    14 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 35,000 Btu/Hr Model 18-1 18-2 18-18 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-3 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11 22 13 13 15 16 17 18 19 20 21 22 39 43 23 24 26 27 28 29 30 31 32 35 36 37 38 22 14 10 11-1 11-2 11-3 11-4 11-5 ...

  • Desa BY35CEB - page 15

    15 103618 OWNER’S MANUAL KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 102432-01 Screw/Lockwasher, 1/2" 6 4 098512-43 Combustion Chamber 1 5 M51108-01 Heat Shield 1 6 M11084-29 Screw, #10-16 x 3/4" 2 7 M16660 Photocell Bracket 1 8 M10908-2 Screw, #6-32 x 3/8" 2 9 HA3019 Photocell Assembl ...

  • Desa BY35CEB - page 16

    16 103618 POR T ABLE FORCED AIR HEA TERS R 1 2 4 3 5 6 7 8 10 11 12 12 14 15 17 20 18 19 21 21 24 28 29 30 31 32 34 38 37 11 13 9 33 35 36 42 43 39 40 23 44 11 41 45 26 25 16 22 27 ILLUSTRA TED PA R T S BREAKDOWN 70,000 Btu/Hr Model 10-6 10-3 10-2 10-4 10-5 10-7 10-1 Motor and Pump Assembly Burner Head Assembly 18-1 18-2 18-18 18-4 18-5 18-6 18-7 1 ...

  • Desa BY35CEB - page 17

    17 103618 OWNER’S MANUAL P ARTS LIST 70,000 Btu/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 ...

  • Desa BY35CEB - page 18

    18 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 100,000 Btu/Hr Model 8-1 8-2 8-4 8-3 8-5 8-7 8-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 17 20 25 26 9 30 31 33 34 35 36 37 38 39 40 41 6 42 9 21 22 23 24 43 44 27 28 16 19 18 47 46 45 29 32 Burner Head Assembly Motor and Pump Assembly 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-13 ...

  • Desa BY35CEB - page 19

    19 103618 OWNER’S MANUAL KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-138 Upper Shell 1 2 102432-01 Screw/Lockwasher, 1/2" 8 3 098512-31 Combustion Chamber 1 4 M16660 Photocell Bracket 1 5 HA3019 Photocell Assembly 1 6 M27417 Drain Plug 1 7 M10908-2 Screw, #6-32 x 3/8" 2 8 ** Burner Head Assembly 1 8-1 100735-15 Nozzle 1 8-2 M1065 ...

  • Desa BY35CEB - page 20

    20 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 150,000 Btu/Hr Model 8-1 8-2 8-4 8-3 8-5 8-7 8-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 17 20 25 26 9 30 31 33 34 35 36 37 38 39 40 41 6 42 9 21 22 23 24 45 44 27 28 16 19 18 43 48 47 46 29 32 8-8 Burner Head Assembly Motor and Pump Assembly 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13- ...

  • Desa BY35CEB - page 21

    21 103618 OWNER’S MANUAL P ARTS LIST 150,000 Btu/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. ...

  • Desa BY35CEB - page 22

    22 103618 POR T ABLE FORCED AIR HEA TERS R ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 35/70,000 Btu/Hr models. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. STANDARD WHEELS AND H ...

  • Desa BY35CEB - page 23

    23 103618 OWNER’S MANUAL EC CONFORMITY DECLARA TION SGB YOUNGMAN Stanestreet, Slingfold, Horsham West Sussex Rh13 7RD United Kingdom (UK) Manufacturer: DESA International, Inc. 2701 Industrial Drive Bowling Green, KY 42101 U.S.A. Kerosene Portable Forced Air Heaters Model Numbers: BY35CEB, BY70CEB, BY100CEB, BY150CEB It is declared that these mod ...

  • Desa BY35CEB - page 24

    W ARRANTY AND REP AIR SERVICE CERTIFICATE OF GENERAL EQUIPMENT - LIMITED 1 YEAR WARRANTY Printed in U.S.A. EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoev ...

Manufacturer Desa Category Electric Heater

Documents that we receive from a manufacturer of a Desa BY35CEB can be divided into several groups. They are, among others:
- Desa technical drawings
- BY35CEB manuals
- Desa product data sheets
- information booklets
- or energy labels Desa BY35CEB
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa BY35CEB.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa BY35CEB, service manual, brief instructions and user manuals Desa BY35CEB. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa BY35CEB.

Similar manuals

A complete manual for the device Desa BY35CEB, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa BY35CEB by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa BY35CEB.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa BY35CEB - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa BY35CEB, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa BY35CEB, that we can find in the current document
3. Tips how to use the basic functions of the device Desa BY35CEB - which should help us in our first steps of using Desa BY35CEB
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa BY35CEB
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa BY35CEB in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa BY35CEB?

Use the form below

If you did not solve your problem by using a manual Desa BY35CEB, ask a question using the form below. If a user had a similar problem with Desa BY35CEB it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)