    Instal la tio n Instructio ns T2 - - P AC, T2 - - NAC T2 - -P HP , T2 - - NHP LEGACY t SERIE S THERMOS T A TS A07047 A07046 Legacy S eries Legacy S eries Pr ogram mab le Th ermos tat Non- - Pr ogramm abl e Th ermost at Designed and Assembl ed in the U.S. A. NOTE : Rea d the e ntire in stru ctio n ma nu al b efo re star ting th e ins talla tion . US ...

  • Bryant T2-PAC - page 2

    ...

  • Bryant T2-PAC - page 3

    1 T ABLE OF CON TENTS P AGE SAFETY CONSIDERA TI ONS 2 ................................ INST ALLA TION CONSIDERA TI ONS 4 .......................... INST ALLA TION 5 ........................................... Step 1 — T herm ostat Lo catio n 5 ............................... Step 2 — In stall Therm ostat 5 .................................. Ste ...

  • Bryant T2-PAC - page 4

    2 SAFE TY CONS IDE RA T IONS Read and foll ow manufacturer inst ructi ons carefull y . Fol low all local el ectri cal codes during inst all ation. Al l wi ring must confor m t o local and nati onal elect rical co de s. Impr op er wirin g or ins tallatio n ma y da ma ge th erm osta t. Reco g niz e safe ty in for matio n. Th is is the s afe ty - - al ...

  • Bryant T2-PAC - page 5

    3 INTRO DUCTIO N Bryant ’ s Legacy t Ser ies programmabl e thermos tats are wal l - -mounted, low - - v olta ge th erm osta ts whic h ma inta in roo m tem per atu re by co ntro lling th e operat ion of a heat ing and/or ai r condi tioni ng syst em. Bot h heat pump and air co nd ition er mo de ls a re av aila ble , each in programmabl e and non - ...

  • Bryant T2-PAC - page 6

    4 INST ALLA TION CONSIDERA TIONS Models There a re four model s in the Legacy Seri es: programmabl e and non - -programmable, AC an d HP . M o de ls T2 - - P A C an d T2 - - NA C are d es ign ed for A C sys tem s, c on tro lling on e stage of cooling and one stage of heati ng. They wil l not operate a heat pump. Models T2 - - PHP and T2 - - NH P ar ...

  • Bryant T2-PAC - page 7

    5 INST ALLA TION Step 1 — Thermostat Location S Approxi mate ly 5 ft (1. 5m) fr om floor . S Close to o r in a freq uen tly u sed ro om , prefe rab ly on a n ins ide p artitio n - ing wa ll. S On a section of wall wi thout pi pes or duct work. Therm ostat shoul d NOT be mounted S Cl ose to a w indow , on an out side wa ll, or next to a door l ead ...

  • Bryant T2-PAC - page 8

    6 b. Di sconnect wir es from exist ing thermost at, one at a tim e. Be careful not to allo w wires to fall ba ck in to the w all. c. As each w ire i s disconnect ed, r ecord wir e color and t ermi nal marking. d. Dis card or recycl e old ther mostat. ENVIRONMENT AL HAZARD Failur e to follo w this ca utio n ma y resu lt in env iro nm en tal dam ag e ...

  • Bryant T2-PAC - page 9

    7 A07153 Fi g. 1 - - Backp lat e Moun tin g 5. Dri ll f our 3/16 - - in. mount ing holes in wall wher e marked. 6. S ecure mounti ng base to w all w ith four s crews and anchors provided. T o avoid uni ntended bending of wal l plat e plas tic , al l four screw s and anchors must be u s e d. Make s ure all wires ext end through hol e in mount ing ba ...

  • Bryant T2-PAC - page 10

    8 7. Adjus t lengt h and rout ing of each wi re to r each proper t erminal and con- nector block on mounti ng base wi th 1/4 - -in. ( 6 mm) of ext ra wi re. St rip onl y 1/4 i n. of i nsulat ion fr om each wir e to prevent adjacent wi res from shor ting toget her when connected. S ee Fig. 2. A07155 Fi g. 2 - - Secur e Wi r es to T ermin al St rip 8 ...

  • Bryant T2-PAC - page 11

    9 O/B - reversing valv e Y1 - Cooling Low Stage Rc - 24 VAC, from cooling equipment Rh - 24 VAC, from heating equipment W - Heating C - Common 24 VAC G - Fan Y/Y2 - Cooling High or Single Stage A09271 Fi g. 3 - - T ermi nal De sign ation s ELECTRICAL O PERA TION HAZA RD Failur e to follo w this ca utio n ma y resu lt in e qu ipm en t da ma ge o r i ...

  • Bryant T2-PAC - page 12

    10 A07158 Fi g. 4 - - Attach Th ermos tat to Backp late 11. Close t hermost at assem bly making s ure pins on back of ci rcuit board align wit h sockets in connect or . 12. T urn O N power t o unit . When power i s appli ed, all di splay i cons are li t f or 2 seconds t o t est the display . Fol lowi ng this , the equi pment t ype for whi ch the th ...

  • Bryant T2-PAC - page 13

    11 and thei r fact ory default setti ngs. N ot all numbers are used in the Legacy Ser ies because not all options are avail able in this ser ies - - and numbering is consist ent across the T1, T2, and T6 t hermostat li nes. Co nfig ur at io n Opti ons - - Summa ry : Opti on 01 - - Equi pment type Optio n 0 3* - - Fahr en heit/Ce ntig rad e Optio n ...

  • Bryant T2-PAC - page 14

    12 T o Ent er t he Co nfig ura ti on Mo de: Pr ess and hol d the F AN key f or about 10 seconds until t he displ ay changes so that only t wo pairs of digi ts are show ing. T he left (programmabl e versi on) or the l ar ge upper (non - -programmabl e versi on) display s hows the configur ation number and the ri ght (progr ammable versi on) or smal ...

  • Bryant T2-PAC - page 15

    13 Opt ion 03 - - Fah ren h eit/ Cent igrad e Selec tion s: F = Fahrenhei t — Defaul t is Fahr enheit. C = Cen tigra de . Sel ects temperat ure measurement unit s. Opti on 04 - - Fan (G) ON with W outpu t Selec tion s: OF = G no t en ergize d with W — This is d efa ult. ON = G ener gized wit h W . This s electi on determines whet her the fan (G ...

  • Bryant T2-PAC - page 16

    14 H — R eversi ng valve output (O/ W2/ B) i s ener gized when HE A T mode i s sel ected. C — R eversi ng valve output (O/W2/ B) i s ener gized when C OOL mode is s elected. Default is C. Opt ion 11 - - Mi nimum De adba nd Be tw ee n He a ting And Co o ling Selec tion s: 01 thr ough 06 — Defaul t i s 02. Sets the min imu m allo wab le nu mb e ...

  • Bryant T2-PAC - page 17

    15 Option 13 - - Ro om Air T emperature Offset Selec tion s: - - 5t o5 _ F— D e f a u l ti s 0 . Thi s option sel ects the number of degrees F to be added to the dis played temp er atu re to ca libra te or d elib era tely misc alib rate th e m ea sure d ro om temperat ure. Optio n 15 - - A uto C hange ov er A v a ilability Selec tion s: O N—T h ...

  • Bryant T2-PAC - page 18

    16 Option 1 8 - - Ba cklight C onfig urat ion Selec tion s: ON, OF — Default is OF . When ON i s sel ected and the thermostat is not batter y operated a low level conti nuous displ ay backlight is al ways on. W ith OF sel ected, the backl ight is only on for a short t ime after the door is opened or a key i s pressed. Cont inuous ba ck ligh t is ...

  • Bryant T2-PAC - page 19

    17 Optio n 26 - - Minimum Co oling Setpoint Selec tion s: 52 _ Ft o9 0 _ F— D e f a u l ti s5 2 _ F. Set s the l owest cool ing set point avai labl e to the us er . Option 2 7 - - Ma ximum Heating Setpoint Selec tion s: 50 _ Ft o8 8 _ F— D e f a u l ti s8 8 _ F. Set s the hi ghest heat ing setpoi nt avai lable t o the user . Option 99 - - Reset ...

  • Bryant T2-PAC - page 20

    18 St ep 4 — Check T hermos tat Op eration The Le ga cy Ser ies the rmo sta ts hav e a b uilt - - in ins taller te st cap ab ility . Use it to check thermost at and equipment operat ion wi thout del ays or set point adjustm ents to forc e he atin g or co olin g . T o enter the I nstal ler T est mode, use the s ame process as is used to enter Inst ...

  • Bryant T2-PAC - page 21

    19 Check li st 1. Run equi pment t hrough sever al heati ng and cooli ng cycles to ensure proper operati on. T o operate t he thermost at i n its normal operati ng mode, cons ult the O wne r ’ s Manu al. 2. If the equipment is to be left in operat ion, the s etpoint s, operati ng mode, and possi bly progr am schedule mus t be proper ly sel ected. ...

  • Bryant T2-PAC - page 22

    20 FEA TURE S AND ACCE SS ORIE S Home , A way , Slee p (pr ogrammabl e mode ls onl y) Thi s feature pr ovides thr ee button select ions whi ch select from three predetermi ned pair s of heat and cool setpoint s. In programmed versions, one of these t hree choices can be sel ected for any pr ogrammed peri od. T o change these set ti ngs, a temperat ...

  • Bryant T2-PAC - page 23

    21 Door Swi tc h When the door is opened, the displ ay changes f rom i ts norma l oper ati on view . The lar ge temperatur e displ ay disappears so it wi ll be avai labl e for ot her user funct ions. If the door i s lef t open for 3 minut es, t he dis play rever ts t o normal oper ati on. Mounti ng Opt ions For those i nst alla tions requi ring i t ...

  • Bryant T2-PAC - page 24

    22 OPE RA TIO NAL AND CO NNECTI ON INFO RMA TI ON Rc/R h Co nn ectio ns For i nstal lat ions having a separat e 24V AC tr ansformer f or heati ng and cooling, the R connect ion can be separ ated int o two connect ions, one for each tr ansformer . T his allo ws isola tion b etw een th e two tra nsfo rm ers to be p res erv ed . T o sep ar ate Rc from ...

  • Bryant T2-PAC - page 25

    23 Minimum On Tim er Once the e quipment has been t urned on, it must r emain on for 3 minutes . A change in m od e o r se tpo int will c an ce l this time r . Cycle T im er Based on the sel ection of 2, 4, or 6 cycles per hour , t his ti mer is set t o 30, 15, or 10 minut es. T his much ti me must el apse fr om the st art of one cycle before anoth ...

  • Bryant T2-PAC - page 26

    24 T a ble 1 – Out puts Equi p Conf ig Tst a t Model COOL STG 1 COOL STG 2 HEAT STG 1 HEAT STG 2 HEAT STG 3 EM HEAT SS AC Opt 1 = AC T 2 --- P A C T 2 --- N A C T 2 --- P H P T 2 --- N H P Y --- --- W --- --- --- --- --- --- SS HP Opt 1 = HP RVS = O Opt 1 0 = C T 2 --- P H P T 2 --- N H P Y, O/B --- --- Y Y, W --- --- W SS HP Opt 1 = HP RVS = B O ...

  • Bryant T2-PAC - page 27

    25 WIRING DIAG RAMS * * C wire not needed for batteries ** Remove jumper when using split power (Indoor and Outdoor units utilize separate transformers). Y1 Y/Y2 W G Rh Rc C C G R R W Y COM Y ** A12246 Fi g. 5 - - Sin gle Sp eed A/C Th erm ostat T ypical In stal lati on ...

  • Bryant T2-PAC - page 28

    26 WIRING DIAG RAMS (cont. ) * * C wire not needed for batteries ** Remove jumper when using split power (Indoor and Outdoor units utilize separate transformers). Y1 Y/Y2 ** A12238 Fi g. 6 - - Sin gle Sp eed HP Th ermost at T yp ical In stall ati on ...

  • Bryant T2-PAC - page 29

    27 WIRING DIAG RAMS (cont. ) Single-Stage Single-Stage Therm ostat Furnace Air Conditioner O/B Heat W W Y/Y2 Y Y Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc R * 24VAC Comm on C COM COM Cool * Indicates connection may not be required/available. Y1 A09246 Fi g. 7 - - Sin gle- - stage Fu rnace wi th Air C ond iti oner an d S pl it P ower NOTE ...

  • Bryant T2-PAC - page 30

    28 WIRING DIAG RAMS (cont. ) Furnace Air Conditioner Heat Stage 2 O/B W2 Heat Stage 1 W W/W1 Cool Stage 1 Y1 Y 1 Cool Stage 2 Y/Y2 Y/Y2 Y/Y2 Fan G G 24V A C Hot Heating Rh R R 24V A C Hot Cooling Rc DHUM 24V A C Comm on C COM C Y1 Thermostat (NA) * * Remove jumper when using split power (Indoor and Outdoor units utilize separate transformers). A122 ...

  • Bryant T2-PAC - page 31

    29 WIRING DIAG RAMS (cont. ) Furnace Heat Pump O RVS Cooling O/B W2 Heat Stage 3 (furnace) WW / W 1 W 2 * Heat/Cool Stage 1 Y1 Y1 Heat/Cool Stage 2 Y/Y2 Y/Y2 Y /Y2 Fan G G 24V A C Hot Heating Rh R R 24V A C Hot Cooling Rc DHUM 24V A C Comm on C COM C Y1 ** * Some heat pumps may designate W1. **Remove jumper when using split power (Indoor and Outdoo ...

  • Bryant T2-PAC - page 32

    30 WIRING DIAG RAMS (cont. ) Fan Coil Air Conditioner O Remove J2 Jumper for heat staging Heat Stage 2 O/B W2 Heat Stage 1 W W 1 Cool Stage 1 Y1 Y1 Y1 Cool Stage 2 Y/Y2 Y/Y2 Y2 Fan G G 24V A C Hot Heating Rh R R 24V A C Hot Cooling Rc 24V A C Comm on C C C Thermostat * *Remove jumper when using split power (Indoor and Outdoor units utilize separate ...

  • Bryant T2-PAC - page 33

    31 WIRING DIAG RAMS (cont. ) Fan Coil Heat Pump OO RVS Cooling O/B W1 W1 Heat Stage 3 W W 2 Heat/Cool Stage 1 Y1 Y1 Y1 Heat/Cool Stage 2 Y /Y2 Y/Y2 Y/Y2 Fan G G 24V A C Hot Heating Rh R R 24V A C Hot Cooling Rc 24V A C Comm on C C C Thermostat *Remove jumper when using split power (Indoor and Outdoor units utilize separate transformers). * A12243 F ...

  • Bryant T2-PAC - page 34

    32 THE RMOS T A T CONFIG URA TI ON RECO RD In staller _________________________ Model Number _____________________________ Date _______________________ A. Hard wa re Confi gura tion __________ Seal Hole I n Wal l B. Mode Settings __________ Mode ( Off, He at, Cool, Au to, Em Heat ) __________ Heat ing Set point V alue __________ Coolin g Setpoin t ...

  • Bryant T2-PAC - page 35

    33 E. Conf iguration Op tions Op tion 01 ____ Equipm en t T ype Op tion 03* ____ Fahr enh eit/Ce ntig rade Sele ction Op tion 04 ____ Fa n (G) on wit h W/W1 Select ion Op tion 07 ____ Zoning Op tion 10 ____ Rever sin g V alve Op tion 11 ____ Minim um Deadban d Betwe en Heatin g and Coolin g Setpoin ts Op tion 12 ____ Sm art Recov ery ( progr am mab ...

  • Bryant T2-PAC - page 36

    34 ...

  • Bryant T2-PAC - page 37

    35 ...

  • Bryant T2-PAC - page 38

    36 ...

  • Bryant T2-PAC - page 39

    ...

  • Bryant T2-PAC - page 40

    Copyright 2012 Bryan t Corporation 7310 W Morris St. I ndianapolis, I N 46231 I I T 2 --- P A C --- 0 5 R e p l a c e s : I I T 2 --- P A C --- 0 4 Edition Date: 05/ 12 Manufa cturer reserves the right to change , a t any time, specif ica tions a nd de signs without notice and wi tho ut obl ig ati o ns. ...

Manufacturer Bryant Category Thermostat

Documents that we receive from a manufacturer of a Bryant T2-PAC can be divided into several groups. They are, among others:
- Bryant technical drawings
- T2-PAC manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant T2-PAC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant T2-PAC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant T2-PAC, service manual, brief instructions and user manuals Bryant T2-PAC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant T2-PAC.

Similar manuals

A complete manual for the device Bryant T2-PAC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant T2-PAC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant T2-PAC.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant T2-PAC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant T2-PAC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant T2-PAC, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant T2-PAC - which should help us in our first steps of using Bryant T2-PAC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant T2-PAC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant T2-PAC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant T2-PAC?

Use the form below

If you did not solve your problem by using a manual Bryant T2-PAC, ask a question using the form below. If a user had a similar problem with Bryant T2-PAC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)