Manual Raypak FlexGas 302BD-2342BD

12 pages 1.33 mb
Download

Go to site of 12

Summary
  • Raypak FlexGas 302BD-2342BD - page 1

    SUPPLEMENT AL INST ALLA TION AND OPERA TING INSTR UCTIONS Catalog No. 1000.58B Effective: 06-24-08 Replaces: 02-22-07 P/N 241295 Rev . 3 Patent No. 6,904,873; Other patent pending FOR Y OUR SAFETY : Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. T o d ...

  • Raypak FlexGas 302BD-2342BD - page 2

    2 Rev . 3 reflects the following: Changes to: step 4 of the FlexGas System Start-up section on page 7; the Wiring Diagram was moved from page 5 to page 9; the addition of: a note to the Attach Manometers to Measure Pressures section on page 7 . ...

  • Raypak FlexGas 302BD-2342BD - page 3

    Raypak strongly recommends that this manual be reviewed thoroughly before installing your Hi Delta heater equipped with FlexGas. Raypak also recom- mends that the appropriate Hi Delta Installation and Operating Instruction manual (1000.501 for 302B- 902B or 1000.51 1 for 992B – 2342B) be thoroughly read before attempting to install these heaters. ...

  • Raypak FlexGas 302BD-2342BD - page 4

    4 All Raypak heaters are National Board Approved, and design-certified and tested by the Canadian Stan- dards Association (CSA) for the U.S. and Canada. Each heater is constructed in accordance with Section IV of the American Society of Mechanical Engineers (ASME) Pressure V essel Code, and bears either the ASME “H” stamp for boilers or “HL W ...

  • Raypak FlexGas 302BD-2342BD - page 5

    5 Gas Supply Pr essure A minimum of 5.0 in. WC and a maximum of 10.5 in. WC upstream gas pressure is required under load and no-load conditions for natural gas. A minimum of 8.0 in. WC and a maximum of 13.0 in. WC is required for propane gas. The gas pressure regulator(s) supplied on the heater is for low-pressure service. If upstream gas pressures ...

  • Raypak FlexGas 302BD-2342BD - page 6

    6 Star t-up F or Y our Safety This appliance has a hot surface igniter(s). It is equipped with an ignition device(s) which automatical- ly lights the burners. Do not try to light the burners by hand. BEFORE OPERA TING, smell all around the appli- ance area for gas. Be sure to smell near the floor because some gas is heavier than air and will settle ...

  • Raypak FlexGas 302BD-2342BD - page 7

    7 Prepar ation Check P ow er Suppl y With multi-meter at incoming power in Hi Delta heater , check voltage between: Hot - Common (≈120 V AC) Hot - Ground (≈120 V AC) Common - Ground (< 1 V AC) Attach Manometers to Measure Pr essures 1. T urn off main gas valves. 2. Attach 24” scale manometer to the first main gas shut-off valve pressure ta ...

  • Raypak FlexGas 302BD-2342BD - page 8

    F r om PR O to NA T: 1. T urn the boiler off (power switch on front control panel). 2. T urn FlexGas key to “OFF”. 3. Close PRO manual valve. 4. Open NA T manual valve. 5. T urn FlexGas key to “NA T”. 6. T urn the boiler on. Safety Inspection 1. Check all thermostats and high limit settings. 2. During the following safety checks leave ma- n ...

  • Raypak FlexGas 302BD-2342BD - page 9

    9 4. Remove all manometers and replace caps and screws. 5. Replace all gas pressure caps. 6. Check for gas leaks one more time. 7. Restart unit. Fig. 5: FlexGas Control Panel Fig. 6 Wiring Diagram * *Optional on 302BD–902BD W iring Dia g ram ...

  • Raypak FlexGas 302BD-2342BD - page 10

    10 ...

  • Raypak FlexGas 302BD-2342BD - page 11

    11 CALL OUT DESCRIPTION 302BD-652BD 752BD-902BD 992BD-1262BD 1532BD-2342BD F 3 4 9 1 1 0 F 3 4 9 1 1 0 F 3 4 9 1 1 0 F 3 4 9 1 1 0 Y S S A H C T I W S Y E K C - 1 F 6 2 1 2 1 0 F 6 2 1 2 1 0 F 6 2 1 2 1 0 F 6 2 1 2 1 0 C A V 0 2 1 T D P S - Y A L E R C - 2 3-C CONNECTOR-WIRE BONDING 007155F 007155F 007155F 007155F 1-G GAS SOLENOID V AL VE (NA T) 01 ...

  • Raypak FlexGas 302BD-2342BD - page 12

    Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A. www .raypak.com ...

Manufacturer Raypak Category Boiler

Documents that we receive from a manufacturer of a Raypak FlexGas 302BD-2342BD can be divided into several groups. They are, among others:
- Raypak technical drawings
- FlexGas 302BD-2342BD manuals
- Raypak product data sheets
- information booklets
- or energy labels Raypak FlexGas 302BD-2342BD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Raypak FlexGas 302BD-2342BD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Raypak FlexGas 302BD-2342BD, service manual, brief instructions and user manuals Raypak FlexGas 302BD-2342BD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Raypak FlexGas 302BD-2342BD.

Similar manuals

A complete manual for the device Raypak FlexGas 302BD-2342BD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Raypak FlexGas 302BD-2342BD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Raypak FlexGas 302BD-2342BD.

A complete Raypak manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Raypak FlexGas 302BD-2342BD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Raypak FlexGas 302BD-2342BD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Raypak FlexGas 302BD-2342BD, that we can find in the current document
3. Tips how to use the basic functions of the device Raypak FlexGas 302BD-2342BD - which should help us in our first steps of using Raypak FlexGas 302BD-2342BD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Raypak FlexGas 302BD-2342BD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Raypak FlexGas 302BD-2342BD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Raypak FlexGas 302BD-2342BD?

Use the form below

If you did not solve your problem by using a manual Raypak FlexGas 302BD-2342BD, ask a question using the form below. If a user had a similar problem with Raypak FlexGas 302BD-2342BD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)