  • Unigreen Mistblowers AP APC - page 1

    USE AND MAINTENANCE MANU AL MISTBLO WERS MOUNTED MISTBLOWERS serie EXPO - CLIO - KAMB A - VENUS - DEVIL - SIRIO - EOLO - AP Read this manual carefully before use. GB 04/2010 ISO Color code ...

  • Unigreen Mistblowers AP APC - page 2

    2 unigreen Summary 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL .................... 4 1. 1 COMPOSITION OF THE MANU AL ....................................................................................... 4 1.2 GUARANTEE .. ..................................................................................................................... ...

  • Unigreen Mistblowers AP APC - page 3

    unigreen 3 6.2.2 LO W V OLUME CONICAL NOZZLES (150-500L/HA) ............................................................ 1 9 6.2.3 ANTI-DRIFT NOZZLES ....................................................................................................... 1 9 6. 3 CALIBRA TING AXIAL F AN A T OMI SERS .................................................. ...

  • Unigreen Mistblowers AP APC - page 4

    4 unigreen Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest atten- tion to the safety of the operator and the environment, nevertheless there are still some residual risks due to the nature of the product used. For this reason we recommend reading all of this manual to avoid making mis- t ...

  • Unigreen Mistblowers AP APC - page 5

    unigreen 5 2 SAFETY REGULATIONS AND RESIDUAL RISKS In relation to saf ety , the f ollowing terms will be used: Dangerous zones: any zone inside and/or near the machine where the pres- ence of a person exposed constitutes a risk for the safety and health of the same person. Person exposed: any person who has their body or any part of their body in a ...

  • Unigreen Mistblowers AP APC - page 6

    6 unigreen 2. 1 INTENDED USE The sprayer in this series is built for agricultural use. The materials used are resistant to normal chemical products used in agricultural spraying (or herbicides) at the time of construction. Any other use is not allowed and the manufacturer is not responsible for any damage caused by aggressive, dense or sticky chemi ...

  • Unigreen Mistblowers AP APC - page 7

    unigreen 7 Refer to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone. (see point 10.4) c) Due to the comple ...

  • Unigreen Mistblowers AP APC - page 8

    8 unigreen 3. 2 NOISE LEVEL OF THE MACHINE Use earmuffs to protect your ears when using the machine, below you will find the data on the maximum noise levels during work. Atomisers with axial fan rotor A COUSTIC PO WER LEVEL emitted by the machine with axial f an rotor : 113.5 and 118.5 dBA respectively in 1st and 2nd gear A COUSTIC PO WER LEVEL A ...

  • Unigreen Mistblowers AP APC - page 9

    unigreen 9 4.1.2 HAND W ASHING T ANKS The atomisers are supplied with an auxiliary hand-washing tank with clean water and a hand tap. This tank must always be supplied with water and the inside must be clean so you can w ash any par ts of the body that come into contact with the chemical product used. Never drink the liquid inside. 4.2 PRELIMINAR Y ...

  • Unigreen Mistblowers AP APC - page 10

    10 unigreen 4.4 TRA CT OR COUPLING The tractor must have 1”3/8 ASAE DIN 9611/A power-takeoff that runs at 550 r pm. It must hav e a 3-point elev ator suitab le f or safely supporting the weight of the atomiser . Check this by consulting the table of allowed fittings N° 14A-15A-16A (pages 37, 38, 39). W ARNING: make sure there are no persons or t ...

  • Unigreen Mistblowers AP APC - page 11

    unigreen 11 4.5 CARDAN SHAFT In some models this is supplied on request. The cardan shaft must bear the CE mark. It must always have its own instructions that must be followed scrupulously and it should come with a cov er bear ing the mark, integrated in ev er y par t . Y ou should ha ve pre viously checked the length to a void: = if it is too long ...

  • Unigreen Mistblowers AP APC - page 12

    12 unigreen 4.8 PRESSURE REGULA T OR T o use the pressure regulator , f ollow the instructions in the enclosed handbook scrupulously . The pressure regulator controls all of the most important spraying functions, the thorough knowledge of its functions makes work easier and more precise. The working pressure and the maximum pressure of the sprayer ...

  • Unigreen Mistblowers AP APC - page 13

    unigreen 13 Pressure regulators with a volumetric valve (GCP ELETTRICO) Adjusting the maximum pressure valve = put main control A in the drain position (“OFF”). = loosen the hand wheel of maximum pressure valve B completely (anticlockwise). = open v olumetric valv e E completely . = start the pump by activating the power-takeoff of the tractor ...

  • Unigreen Mistblowers AP APC - page 14

    14 unigreen 4. 10 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks. The pipe used for filling must never come into contact with the liquid in ...

  • Unigreen Mistblowers AP APC - page 15

    unigreen 15 FIG. 13 FIG. 14 FIG. 15 a) high-pressure machines from 30 to 60 bar (FIG. N° 13): run the stirrer (or ejector) for roughly 10-15 minutes at the maximum pressure available b) low pressure machines, max 20 bar = with a drilled pipe on the drain, run the pump at roughly 540 RPM with the pressure regulator on drain f or at least 10-15 minu ...

  • Unigreen Mistblowers AP APC - page 16

    16 unigreen 5 BLO WER GROUP All the atomisers ha ve a high speed fan r otor . Y ou must take great care and beware of the effects that this can provoke: such as the aspiration and projection of foreign bodies which, although of a small size, can be very dangerous especially for the eyes and face. 5. 1 AXIAL BLOWER GROUP WITH PULLEY The atomisers th ...

  • Unigreen Mistblowers AP APC - page 17

    unigreen 17 WORK TEMPERA TURE Heat is generated by the friction between the various moving components and on the basis of the pow er transmitted. The temperature of the multiplier or disengaging box depends on the capacity to dissipate heat to the surrounding environment and therefore the surfaces involved in the heat exchange and the environmental ...

  • Unigreen Mistblowers AP APC - page 18

    18 unigreen 5. 5 CLUTCH Big aluminium and nylon blowers have a centrifugal type clutch that makes it possible to engage the f an rotor gradually . This pre vents jerky star ts, due to the inertia of the fan rotor , which can hav e a negative effect on the transmission. For the centrifugal clutch to work properly the speed of the power-takeoff mustn ...

  • Unigreen Mistblowers AP APC - page 19

    unigreen 19 T o pre vent the e xcessive heating of the oil we recommend supplying the distributor of the sprayer only when the cylinders are being used. We recommend having qualified personnel do any adjustments. P ay attention to the integrity and efficiency of the h ydraulic components and in par ticular to the pipes to pre vent the risk of burst ...

  • Unigreen Mistblowers AP APC - page 20

    20 unigreen 6. 3 CALIBRA TING AXIAL F AN A T OMISERS (T ables on pages 25 - 30) The tables on pages 25-30 let you easily calculate the distribution in litres/ hectare of the atomisers with the standard fittings, proceeding as indicated below: a) Choose the table relevant to the blower group of the atomiser in question (the main reference is the num ...

  • Unigreen Mistblowers AP APC - page 21

    unigreen 21 6.4.2 TREA TMENTS ON HERBA CEOUS CUL TIV A TIONS a) Use the tables of pages 31-33 choosing the one relevant to the type of cannon to use and the number of jets. b) Find the r ange and the diameter of the nozzles used (ceramic plate or TR nozzles). c) In the horizontal strip, choose the working speed and the distribution in litres/hectar ...

  • Unigreen Mistblowers AP APC - page 22

    22 unigreen 8 MAINTENANCE All of the maintenance operations and repairs must be carried out with the ma- chine and cardan shaft stopped and the tank and circuit clean of any residues of chemical products. The maintenance of the atomiser is essential for maintaining a high level of safety . Also consult the single handbooks of the main components of ...

  • Unigreen Mistblowers AP APC - page 23

    unigreen 23 We recommend having the normal UNIGREEN assistance service available from our reseller perf orm any repairs or contact a specialised workshop . Dur ing all of the repairs, in particular when welding, the machine and the circuit must be clean of any residues of chemical product. If the machine has to be lifted (for example to change a wh ...

  • Unigreen Mistblowers AP APC - page 24

    24 unigreen Commonly used spare parts part description code single Ø18 non-drip jet for atomiser with diaphragm (1/4" mount) without nozzles 1224/0194F double Ø18 non-drip jet for atomiser with diaphragm (1/4" mount) without nozzles 1224/0195F double 15 + Ø18 non-drip jet Ø for cannon with diaphragm (1/4" mount) without nozzles 1 ...

  • Unigreen Mistblowers AP APC - page 25

    unigreen 25 T ABLES FOR CALIBRA TING A TOMISERS Ø500-600 T ABLES FOR CALIBRA TING A T OMISERS N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). unigreen s pa Tabella e r og a z io ne in L it r i/e t t ...

  • Unigreen Mistblowers AP APC - page 26

    26 unigreen T ABLES FOR CALIBRA TING A T OMISERS Ø600-650 T ABLES FOR CALIBRA TING A T OMISERS N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). unigreen s pa Ta bella e ro gazione in Lit ri/et t a ro ...

  • Unigreen Mistblowers AP APC - page 27

    unigreen 27 T ABLES FOR CALIBRA TING A TOMISERS Ø700-750 T ABLES FOR CALIBRA TING A T OMISERS N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). unigreen s pa T a be l l a e rog a z i o n e i n L i tri ...

  • Unigreen Mistblowers AP APC - page 28

    28 unigreen T ABLES FOR CALIBRA TING A T OMISERS T ABLES FOR CALIBRA TING A T OMISERS Ø800 N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). uni green s pa T a b ella e r o gazio n e in L it r i/et t a ...

  • Unigreen Mistblowers AP APC - page 29

    unigreen 29 T ABLES FOR CALIBRA TING A T OMISERS T ABLES FOR CALIBRA TING A T OMISERS Ø900 N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). uni gree n s p a T a bella e r og a zion e in Lit ri /e t t ...

  • Unigreen Mistblowers AP APC - page 30

    30 unigreen T ABLES FOR CALIBRA TING A T OMISERS T ABLES FOR CALIBRA TING A TOMISERS Ø650 TGZ T ABLES FOR CALIBRA TING A TOMISERS Ø800 TGZ N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). unigreen s ...

  • Unigreen Mistblowers AP APC - page 31

    unigreen 31 T ABLES FOR CALIBRA TING CANNONS T ABLES FOR CALIBRA TING CANNONS Ø450 N.B. to calculate the different ranges extension it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). N.B. to obtain better agitaton in the tank, verify that th ...

  • Unigreen Mistblowers AP APC - page 32

    32 unigreen T ABLES FOR CALIBRA TING CANNONS T ABLES FOR CALIBRA TING CANNONS Ø400-455 N.B. to calculate the different ranges extension it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). N.B. to obtain better agitaton in the tank, verify tha ...

  • Unigreen Mistblowers AP APC - page 33

    unigreen 33 T ABLES FOR CALIBRA TING CANNONS T ABLES FOR CALIBRA TING CANNONS Ø400-455 TIL TING HEAD N.B. to calculate the different ranges extension it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20). N.B. to obtain better agitaton in the ta ...

  • Unigreen Mistblowers AP APC - page 34

    34 unigreen T ABLE OF DELIVER Y IN LITRES / MIN. LO W V OLUME TXA CONICAL NOZZLES FOR A T OMISER NOZZLE TXA80 ISO LILLA C O LIVE ORANGE GREEM YELLO W D ARK BLUE R E D BROWN 005 0067 01 015 0 2 03 0 4 05 PRESSURE 5 b a r 0,25 0,35 0,51 0,76 1,03 1,53 2,04 2,55 7 bar 0,30 0,41 0,60 0,90 1,22 1,81 2,41 3,01 10 bar 0,36 0,49 0,72 1,07 1,45 2,17 2,88 3, ...

  • Unigreen Mistblowers AP APC - page 35

    unigreen 35 T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR LEVER LANCE note: standard Ø1,5 nozzle DIAMETER NOZZLE Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,75 Ø 2,0 Ø 2,2 Ø 2,5 PRESSURE (BAR) J E T CAP ACITY ( Lt / min ) 5 cone 1,16 1,40 1,90 2,25 2,65 2,90 3,50 direct jet 1,40 1,70 2,50 3,95 4,7 6,00 7,70 8 cone 1,40 1,80 2,60 2,80 3,40 3,65 ...

  • Unigreen Mistblowers AP APC - page 36

    36 unigreen T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 5 0 h 300 h END OF SEASON Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 Check and clean the suction 0 and delivery filters Check the pump fixing feet 0 and screws in general Check the diaphragm and the oil X (1 ) ...

  • Unigreen Mistblowers AP APC - page 37

    unigreen 37 T AB.14A ALLOWED FITTINGS 2009 A TO M I Z ZA T O R I P OR TA T I T Y PE O F PL T MA CH INE Tr uc k - mounted mi s tb l ow ers TA B. 1 4 a EX PO P EX PO A EX PO M K A M B A FITTI NG CLIO P - A P P CLIO M - A P M V EN US - A P TOP 150 201 301 402 300 400 600 202 302 410 402 402 600 600 800 300 400 600 F UN " " Ø5 00 N Y LO N X ...

  • Unigreen Mistblowers AP APC - page 38

    38 unigreen T AB.15A ALLOWED FITTINGS 2007 A TO M I Z Z A T OR I P OR T A TI A T OM I Z Z A TO R I P OR T A TI c o n M OLT I P LI C A TO R E TY P E OF c o n P ULE GGI A Tr ac tor- mount ed mis tb l ow er s w i th GEA RBOX MA CHINE Tr uc k - mou nted m i s tb l ow er s w i th B ELT DRIVE TA B. 15 a D E VI L - P D E V I L - T G Z S I R I O - E O LO F ...

  • Unigreen Mistblowers AP APC - page 39

    unigreen 39 T AB.16A ALLOWED FITTINGS 2 0 0 7 AT O M I ZZ AT O R I P O R T AT I A C AN N O N E TY P E OF T r ac tor - mou nted m i s tb l ow er s " Cann on T ype" MA CHINE TA B. 16 a EOL O C - S IRI O C B O RA - A P C AP C AP C FITTI NG N om inal cap ac ity ( l t. ) 30 0 4 00 600 600 800 8 00 1000 1 000 F A N C E N T R I F U GA L Ø 450/2 ...

  • Unigreen Mistblowers AP APC - page 40

    Descriptions, indicative illustrations, UNIGREEN S.P.A. reserves the right to make variations or modifications without prior warning. via Rinaldi, 105 - 42124 Reggio Emilia - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group UNI 16100005F - GB Apr-10 ...

Manufacturer Unigreen Category Outdoor Misting Fan

Documents that we receive from a manufacturer of a Unigreen Mistblowers AP APC can be divided into several groups. They are, among others:
- Unigreen technical drawings
- Mistblowers AP APC manuals
- Unigreen product data sheets
- information booklets
- or energy labels Unigreen Mistblowers AP APC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Unigreen Mistblowers AP APC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Unigreen Mistblowers AP APC, service manual, brief instructions and user manuals Unigreen Mistblowers AP APC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Unigreen Mistblowers AP APC.

Similar manuals

A complete manual for the device Unigreen Mistblowers AP APC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Unigreen Mistblowers AP APC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Unigreen Mistblowers AP APC.

A complete Unigreen manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Unigreen Mistblowers AP APC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Unigreen Mistblowers AP APC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Unigreen Mistblowers AP APC, that we can find in the current document
3. Tips how to use the basic functions of the device Unigreen Mistblowers AP APC - which should help us in our first steps of using Unigreen Mistblowers AP APC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Unigreen Mistblowers AP APC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Unigreen Mistblowers AP APC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Unigreen Mistblowers AP APC?

Use the form below

If you did not solve your problem by using a manual Unigreen Mistblowers AP APC, ask a question using the form below. If a user had a similar problem with Unigreen Mistblowers AP APC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)