    Instr uctions GBL 7500 Bo x Lubricator Pump GBL Shaft Rotation/Lo w Le vel Alarm Pump 3A2257C EN GBL 7500 Bo x Lubricator Pump: Fully enc losed, self-lubricati ng, precision, metering pump capable of pumping small flows of either mineral or synthetic oil to machinery injection points. For prof essional use only . GBL Shaft Rotation/Low Le vel Alarm ...

  • Graco 24J392 - page 2

    Warnings 2 3A2257C Wa r n i n g s The f ollowing w ar nings are f or the setup , use , grounding, maintenan ce, and repair of this equipme nt. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols ref er to procedur e-specific risks. When these symbols appear in the body of this manual , ref er ba ck to these W a ...

  • Graco 24J392 - page 3

    Warnings 3A2257C 3 EQUIPMENT MISUSE HAZARD Misuse can caus e death or ser ious injur y . • Do not oper ate the unit when f atigued or under the influence of drugs or alcoh ol. • Do not e xceed the maxim um working pressure or temper ature rating of the low est rated system compo - nent. See Te c h n i c a l D a t a in all equipme nt manuals. ? ...

  • Graco 24J392 - page 4

    Warnings 4 3A2257C Pressure Relief Pr ocedure 1. Stop lube pu mp. 2. If installed, close oil supply v alv e located upstre am from pump. 3. If installed, open drain v alv e located downst ream from the pump . 4. Slowly cr ack open fluid line fit tings to relie ve pr es- sure. Installing the Pump Gr ounding Ensure the reservoir is properly grou nded ...

  • Graco 24J392 - page 5

    Setup 3A2257C 5 b . F or all installations (whether the tube needs to be tr immed or ca n be used wit hout tr imming), press strainer onto end of the suction tube until it “bottoms” (F IG . 3). 4. Orient pump so the roller bearing on the bottom of the pump is aligned with the cam insid e the reser- vo ir. 5. Install pump on the reser v oir by a ...

  • Graco 24J392 - page 6

    Setup 6 3A2257C Suction Fed Models (F IG . 4) 1. Remov e the sight w ell plug (1) and outlet plug (5 ). Discard outlet plug (5). 2. Fill the sight well (2) to th e top with appropriately fil- tered oil. 3. Operate th e hand priming assembly (3) until t he oil le vel dro ps below the end of th e drip tube (4). 4. Apply th read sealant (user supp lie ...

  • Graco 24J392 - page 7

    Setup 3A2257C 7 Pressure Fed Models (F IG . 6) NO TE: In the f ollowing instructions , the fill line ref ers to the inlet line. 1. Remov e and d iscard the inlet p lug (1) and o utlet plug (5). 2. Apply thread sealant (user supplied) to fill line fitting. 3. Connect fill line to inlet (2). 4. T orque fill line fitting to 85 + 10 in. lbs (9.60 + 1.1 ...

  • Graco 24J392 - page 8

    Setup 8 3A2257C Connecting Lube Lines to Pump: Suction, Gravity and Pressur e Fed Pump Models Only NO TE: The lube line ref ers to the outlet line supplying lubricant to the lubr ication points. 1. Apply th read sealant (user supplied ) to lube line f it- ting. 2. Connect lube line to pump out let (6), (F IG . 8)(also see pages 15 and 16). 3. T orq ...

  • Graco 24J392 - page 9

    Setup 3A2257C 9 3. For Suction Fed and Gravity Fed models onl y: With the lubricator oper ating, count the dr ops from the drip tube (4) falling into the sight w ell (2) fo r one minute . The number of drops seen f a lling in the sight well equals the amount of oil discha rged by the pump . See Specifi- cations , page 10 f or additional inf or mati ...

  • Graco 24J392 - page 10

    Specifications 10 3A2257C Specifications Ta b l e 1 Drops per Stroke T able Section of T able A pplies to Suction and Gra vity Fed Models Only • Allow able viscosity range independent of te mperature: 80-50 00 SUS. • Strok es/Minute - Maxim um - 50; Minimum - 3 • Strok e Length - Maximum 1/ 2 inch (12.7 mm) † Ref er to your manuf acturer’ ...

  • Graco 24J392 - page 11

    Troubleshooting 3A2257C 11 T roub leshooting * Oil le vel in sight well will rise and f all dur ing nor mal operati on. If condition persis ts refer to Cause/ Solution sections. I Prob lem Cause Solution Pump does not flo w Pump stroke is adjusted to zero . Adjust pump stroke f or desired out- put. See page 8. Pump outlet is plugg ed. Clean/flush p ...

  • Graco 24J392 - page 12

    Maintenance 12 3A2257C Maintenance Sight W ell Fills With Oil The oil le vel in the sight well (2) will rise and fall slightly during pump operation . Should the oil le vel in t he sight well rise abov e the dr ip tube (4): 1. Remove the sight well plug ( 1). 2. Allow the pump to continue to opera te until the oil le vel has dropped belo w the drip ...

  • Graco 24J392 - page 13

    Technical Data 3A2257C 13 Te c h n i c a l D a t a * Sensor output will open at 10 0-200 psi (0.68 MP a, 6.89 bar). Suction, Gravity Pressure Fed Bo x Lubricator Pump or Shaft Rota tion Alarm Pump Maximum W orking Pressure US Metric All 3/16” Piston Models 7500 psi 51.7 MP a, 517 bar All 1/4” Piston Models 6000 psi 41.4 MP a, 414 bar All 3/8” ...

  • Graco 24J392 - page 14

    Technica l Data 14 3A2257C Pump Dimensions Dimension Inches mm A 3.10 76.20 B 1.97 50.04 C 0.50 12.70 D Pump Min. 2.58 Pump Max. 3.18 Pump Min. 65.53 Pump Max.78.23 E5 . 3 7 1 3 6 . 4 0 F Min. 4.14 Max 4.90 Min. 105.20 Max 124.50 G 1.50 38.10 H 0.50 12.70 J 0.50 12.70 K 0.39 9.90 L 0.92 23.37 M 0.28 7.11 N 5.40 13 7.20 P 3.85 97.79 R 10.13 257.18 K ...

  • Graco 24J392 - page 15

    Technical Data 3A2257C 15 Gravity Fed Pressure Fe d Inlet P A Outlet C D Outlet Inlet A B C D ...

  • Graco 24J392 - page 16

    Technica l Data 16 3A2257C Suction Fed Outlet C D A P N Inlet ...

  • Graco 24J392 - page 17

    Technical Data 3A2257C 17 Alarm Pump C D P N Inlet R Retur n to Reser v oir 1/4 NPT Sensor Output ...

  • Graco 24J392 - page 18

    All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts. Original instructions. This manua l contains English. MM 3A2257 Graco Headquarters: Minneap ...

Manufacturer Graco Category Heat Pump

Documents that we receive from a manufacturer of a Graco 24J392 can be divided into several groups. They are, among others:
- Graco technical drawings
- 24J392 manuals
- Graco product data sheets
- information booklets
- or energy labels Graco 24J392
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco 24J392.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco 24J392, service manual, brief instructions and user manuals Graco 24J392. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco 24J392.

Similar manuals

A complete manual for the device Graco 24J392, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco 24J392 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco 24J392.

A complete Graco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco 24J392 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco 24J392, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco 24J392, that we can find in the current document
3. Tips how to use the basic functions of the device Graco 24J392 - which should help us in our first steps of using Graco 24J392
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco 24J392
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco 24J392 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco 24J392?

Use the form below

If you did not solve your problem by using a manual Graco 24J392, ask a question using the form below. If a user had a similar problem with Graco 24J392 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)