    INSTRUCTION MANUAL P ART NO. A08591 Rev . 0 11/04 Copyright © 2004 Delta Machinery T o lear n more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (66-501-1) ESP AÑOL: PÁGINA 25 FRANÇAIS: P AGE 49 ...

  • Encore electronic (66-501-1) - page 2

    2- ENG A08591 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor ...

  • Encore electronic (66-501-1) - page 3

    3- ENG A08591 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is norm ...

  • Encore electronic (66-501-1) - page 4

    4- ENG A08591 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an ...

  • Encore electronic (66-501-1) - page 5

    5- ENG A08591 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • Encore electronic (66-501-1) - page 6

    6- ENG A08591 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance ...

  • Encore electronic (66-501-1) - page 7

    7- ENG A08591 Review and underst and all instructio ns and warnings in this manual. Become famil iar with the operation and contr ols of the air compresso r . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times . Do not operate the produc t when fatigue d or under the influenc e ...

  • Encore electronic (66-501-1) - page 8

    8- ENG A08591 Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been e ...

  • Encore electronic (66-501-1) - page 9

    Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the com ...

  • Encore electronic (66-501-1) - page 10

    10- ENG A08591 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see ...

  • Encore electronic (66-501-1) - page 11

    11- ENG A08591 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights, ...

  • Encore electronic (66-501-1) - page 12

    Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : T ur n this switch ON to provide automatic power to the pressur e switch and OFF to remove power at the end of each use. Pressur e Switch: The pressure switch automatically starts the motor when the air tank pressur e drops below the factory ...

  • Encore electronic (66-501-1) - page 13

    13- ENG A08591 How to Use Y our Unit How to Stop: 1. Set the On/Auto/Off lever to "OFF". Before Each Start-Up: 1. Place On/Auto/Off lever to "OFF". 2. Pull regulator knob out, tur n counterclockwise until it stops. Push knob in to lock in place. 3. Attach hose and accesso ries. NOTE: The hose or accessory will re quir e a quick ...

  • Encore electronic (66-501-1) - page 14

    14- ENG A08591 Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D ra in T an k ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to make sure that ...

  • Encore electronic (66-501-1) - page 15

    T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc moves freely ins ...

  • Encore electronic (66-501-1) - page 16

    16- ENG A08591 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wrench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator an ...

  • Encore electronic (66-501-1) - page 17

    17- ENG A08591 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress ...

  • Encore electronic (66-501-1) - page 18

    18- ENG A08591 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in t ...

  • Encore electronic (66-501-1) - page 19

    19- ENG A08591 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check th ...

  • Encore electronic (66-501-1) - page 20

    20- ENG A08591 AIR COMPRESSOR DIAGRAM 21 5 13 16 4 3 9 10 1 15 6 14 12 11 8 7 7 17 20 2 18* * IMPORT ANT : Some models were built with a check valve and bushing reducer . If check valve needs to be replaced, remove the old check valve and reducer bushing before replacing with the pr eferr ed one piece check valve (Key 18). ...

  • Encore electronic (66-501-1) - page 21

    21- ENG A08591 P ARTS LIST K e y N o P a r t N u m b er D es cr ip ti o n 1 TI A-41 50 Sa fety V alve 2 A0 6891 Dr ain V alv e 3 CA C-42 99 Wh eel 6 " (2 ) 4 CA C-60 Sh ould er Bo lt (2 ) 5 SS F-80 80- ZN Nu t Hex 3/8 -16 ( 2) 6 AC -034 5 Ha ndle 7 SS F-61 2 Scr ew #1 0-1 6 x 1(2 ) 8 AC -036 4 Mo lded Fo ot Bum per 9 Z- D272 27 Pr es su re Swi ...

  • Encore electronic (66-501-1) - page 22

    22- ENG A08591 AIR COMPRESSOR PUMP DIAGRAM 9 3 18 5 6 8 14 17 15 1 2 25 4 T o rque 49-55 in.-lbs. T o rque 30-45 in.-lbs. T o rque 10 in.-lbs. Max 9-13 9-12 9-8 9-9 9-10 9-11 7 10 22 16 24 T orque 30 in.-lbs. ...

  • Encore electronic (66-501-1) - page 23

    23- ENG A08591 P ARTS LIST Key No. Part No. Description ★ 1 ----- Shroud - Left ★ 2 ----- Shroud - Right 3 ----- Cylinder Head ▲ 4 CAC-1212 T ube Seal ▲ 5 ----- Head Gasket 6 Z-A08548 V alve Plate Assembly 7 DAC-269 Outlet T ube ▲ 8 ----- Gasket 9 Z-A04647 Sub Pump Assembly ◆ 9-8 ----- Rod Assembly • 9-9 ----- Pre-Formed Compression R ...

  • Encore electronic (66-501-1) - page 24

    24- ENG A08591 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 ...

Manufacturer Encore electronic Category Air Compressor

Documents that we receive from a manufacturer of a Encore electronic (66-501-1) can be divided into several groups. They are, among others:
- Encore electronic technical drawings
- (66-501-1) manuals
- Encore electronic product data sheets
- information booklets
- or energy labels Encore electronic (66-501-1)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Encore electronic (66-501-1).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Encore electronic (66-501-1), service manual, brief instructions and user manuals Encore electronic (66-501-1). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Encore electronic (66-501-1).

A complete manual for the device Encore electronic (66-501-1), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Encore electronic (66-501-1) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Encore electronic (66-501-1).

A complete Encore electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Encore electronic (66-501-1) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Encore electronic (66-501-1), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Encore electronic (66-501-1), that we can find in the current document
3. Tips how to use the basic functions of the device Encore electronic (66-501-1) - which should help us in our first steps of using Encore electronic (66-501-1)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Encore electronic (66-501-1)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Encore electronic (66-501-1) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Encore electronic (66-501-1)?

Use the form below

If you did not solve your problem by using a manual Encore electronic (66-501-1), ask a question using the form below. If a user had a similar problem with Encore electronic (66-501-1) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)