  • White Rodgers HC-TST501CMMS - page 1

    Manual 37-6943A 0830 Dealer Installation and Start-Up Instructions 500 Series Thermostat Featuring Serial Communication (-)HC-TST501CMMS ...

  • White Rodgers HC-TST501CMMS - page 2

    T o prevent electrical shock and/or equipment damage , disconnect electric power to system at main fuse or circuit breaker bo x until installation is complete. Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. W ARNING W ARNING Introduction to Thermostat and Comm unicating System T ...

  • White Rodgers HC-TST501CMMS - page 3

    T able of Contents Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Battery Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Quick Installation Steps ...

  • White Rodgers HC-TST501CMMS - page 4

    This document provides inf ormation for installation of the touchscreen thermostat only . Installation instr uctions of the furnace or air handler and outdoor AC condensing unit or heat pump are provided with each of these de vices. This thermostat is designed exclusively f or this Comfort Control 2 System TM equipment ONL Y . Battery Location 2 ? ...

  • White Rodgers HC-TST501CMMS - page 5

    2 Week History (2 WK HIST) P arameter Indications Comments 2wk Y1 Hrs XXX 2 Week First Stage Cooling Hours of Operation 2wk Y1 Cycles XXXX 2 Week First Stage Cooling Cycles 2wk Y2 Hrs XXX 2 Week Second Stage Cooling Hours Operation 2wk Y2 Cycles XXXX 2 Week Second Stage Cooling Cycles Advanced Installer Confi guration Menu Life History (LIFE HIST) ...

  • White Rodgers HC-TST501CMMS - page 6

    P ower Up T ur n on A C power to the system. The ther mostat will automatically identify the communicating components installed. Messages at Thermostat During power up , the thermostat will scroll the word “SEARCHING” in the message area, indicating that the system is looking for components (Air Handler , Fur nace, Heat Pump , Air Conditioner) ...

  • White Rodgers HC-TST501CMMS - page 7

    Check System Operation Fan Operation • T ur n po wer on to the system. • Press Run Schedule . • Press F AN until F AN On is displayed. The f an should begin to operate. • Press F AN until F AN Auto is displa yed. The fan should stop operating. Heating System • Press Run Schedule . • Press SYSTEM ke y until Heat is display ed. • Press ...

  • White Rodgers HC-TST501CMMS - page 8

    Set Current Time and Day On Home Screen Display , touch the Menu key to displa y additional key choices . T ouch Set Time once to display hour and AM or PM designation in clock display . T ouch either the or k ey until you reach the correct hour and AM or PM designation. Then touch Set Time again to display min utes only in clock display . T ouch a ...

  • White Rodgers HC-TST501CMMS - page 9

    Dipswitch* Dip Switch Indications Comments Cool Airfl o w XXXXCFM View Airfl ow Dipswitches HT Pump Airfl o w XXXXCFM View Heat Pump Airfl ow Dips witch Settings Cool Air Adj -10%, 0%, 10% View Airfl ow T r im Settings On-Demand Dehum On, Off Activ ate Dehumidifi cation Feature * Dipswitch status is not required when the system is set up f or ...

  • White Rodgers HC-TST501CMMS - page 10

    Set Up Thermostat Options The Ther mostat has options that can be selected and adjusted. These options are in the Ther mostat Options Confi guration Men u. On the Home Screen Display , touch the Menu ke y to display additional ke y choices. T ouch and hold the Installer Confi g ke y for 3 seconds . This displa ys the fi rst menu item as shown in ...

  • White Rodgers HC-TST501CMMS - page 11

    Advanced Installer Confi guration Menu Dipswitch* Dip Switch Indications Comments Cool Airfl o w XXXXCFM Airfl o w Dipswitch Settings Heat Rise Nom, Nom+10 Heat Rise Airfl ow Settings Hi Heat Adj -15%, -7%, 0%, 7%, 15% High Heat Airfl ow Settings Lo Heat Adj -15%, -7%, 0%, 7%, 15% Low Heat Airfl ow Settings F an Spd Select Lo , Hi Fan Speed S ...

  • White Rodgers HC-TST501CMMS - page 12

    1 2 Select continuous backlight. Scrolling message will show “ BA CKLIGHT” . When bL is selected On the backlight will be on continuously . Selecting bL OFF will allow the bac klight to tur n on momentarily when any ke y is touched. If system power is off and thermostat is operating on battery only , and bL is On, bL will turn the backlight on ...

  • White Rodgers HC-TST501CMMS - page 13

    Advanced Installer Confi guration Menu Status 2 P arameter Indications Comments Mode Mod Heat, Lo Heat, Hi Heat, AC1, A C2, Fan Only , Off, HP1, HP2 Indicates Operating Mode of System Motor Mfgr Regblt, Emerson Blower Motor Man ufacturer Motor RPM RPM Blower Motor RPM Maximum CFM CFM XXXX Maximum CFM Blow er Provides Blower CFM CFM XXXX Displa ys ...

  • White Rodgers HC-TST501CMMS - page 14

    Select UV lamp maintenance reminder . Scrolling message will sho w “ UV LAMP MAINTENANCE” . Default is OFF . It can be changed to a setting from 25 to 1975 days in increments of 25 days to select the amount of time f or the reminder . Setting of 350 days is an annual reminder . Based on this setting, the scrolling message area will show “ CHA ...

  • White Rodgers HC-TST501CMMS - page 15

    System Operation T ouch the SYSTEM key to select the thermostat operating mode desired. When the system is calling for fi rst stage heat or cool, “Low” will display on the touchscreen. When second stage is required, the display will sho w “High” . The setpoint temperature can be changed by touching the or keys. A uxiliary Heating Heat Pump ...

  • White Rodgers HC-TST501CMMS - page 16

    Programmab le Mode If Program da ys per week is set for 7 (7 da ys) in the Ther mostat Options Confi guration Menu the thermostat can f ollow the program entered. Press the Run Schedule ke y . The thermostat will f ollow the program that y ou entered or the factory program. T emporar y Pr ogram Override This feature will o verride the program temp ...

  • White Rodgers HC-TST501CMMS - page 17

    A uto Mode In Programmab le mode or Non-programmab le mode, you can touch the SYSTEM ke y to select AU TO to allow the thermostat to automatically change between Heat and Cool. When the SYSTEM k ey is touched to select Aut o the ther mostat will change to Heat or Cool, whichev er ran last. If it switches to heat but y ou want cool, or it changes to ...

  • White Rodgers HC-TST501CMMS - page 18

    Maintenance Reminder Message A reminder will display in the scrolling message area when it is time f or accessor y maintenance if selected in the Ther mostat Options Confi guration Men u. When a reminder appears, it can be cleared b y touching the Clean Display ke y . This will also reset the timer to begin a new time period f or the reminder . Ai ...

Manufacturer White Rodgers Category Thermostat

Documents that we receive from a manufacturer of a White Rodgers HC-TST501CMMS can be divided into several groups. They are, among others:
- White Rodgers technical drawings
- HC-TST501CMMS manuals
- White Rodgers product data sheets
- information booklets
- or energy labels White Rodgers HC-TST501CMMS
All of them are important, but the most important information from the point of view of use of the device are in the user manual White Rodgers HC-TST501CMMS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals White Rodgers HC-TST501CMMS, service manual, brief instructions and user manuals White Rodgers HC-TST501CMMS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product White Rodgers HC-TST501CMMS.

A complete manual for the device White Rodgers HC-TST501CMMS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use White Rodgers HC-TST501CMMS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of White Rodgers HC-TST501CMMS.

A complete White Rodgers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual White Rodgers HC-TST501CMMS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the White Rodgers HC-TST501CMMS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the White Rodgers HC-TST501CMMS, that we can find in the current document
3. Tips how to use the basic functions of the device White Rodgers HC-TST501CMMS - which should help us in our first steps of using White Rodgers HC-TST501CMMS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with White Rodgers HC-TST501CMMS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of White Rodgers HC-TST501CMMS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning White Rodgers HC-TST501CMMS?

Use the form below

If you did not solve your problem by using a manual White Rodgers HC-TST501CMMS, ask a question using the form below. If a user had a similar problem with White Rodgers HC-TST501CMMS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)