  • Enterasys Networks VH-8G-L3 - page 1

    Vertical Horizon VH-8G-L3 Gigabit Ethernet Switch USER GUIDE 9033705-01 ...

  • Enterasys Networks VH-8G-L3 - page 2

    ...

  • Enterasys Networks VH-8G-L3 - page 3

    Notice 9033705-01 9033705-01 ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networ ks to determin ...

  • Enterasys Networks VH-8G-L3 - page 4

    Notice 9033705-01 FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and foun ...

  • Enterasys Networks VH-8G-L3 - page 5

    Notice 9033705-01 9033705-01 CLASS A ITE NOTICE WARNING: This is a class A product. In a domes tic environment this product may cause radio interference in which case the user may be required to take adequate measures. ...

  • Enterasys Networks VH-8G-L3 - page 6

    Notice 9033705-01 ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreem ent” ) between You, the end user, and Enterasys Networks, Inc. (“Enterasys”) that sets forth y our rights and obligations with respect to the Ent ...

  • Enterasys Networks VH-8G-L3 - page 7

    Notice 9033705-01 If the Program is exported from the United St ates pursuant to the License Exception TSR under the U.S. Export Administration Regula tions, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology t ...

  • Enterasys Networks VH-8G-L3 - page 8

    Notice 9033705-01 ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAM AGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. ...

  • Enterasys Networks VH-8G-L3 - page 9

    Notice 9033705-01 DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Netw orks, Inc. Manufacturer’s Address: 500 Spaulding Turnpike PO Box 3060 Portsmouth, NH 03801 European Representative Add ress: Enterasys Networks Ltd. Nexus House, New bury Business Park London Road, Newbur y B ...

  • Enterasys Networks VH-8G-L3 - page 10

    ...

  • Enterasys Networks VH-8G-L3 - page 11

    1 9033705-01 Table of Contents PREFACE ................................................................................ 3 Purpose .......................................................................... 3 Audience ....................................................................... 3 Conventions ................................................ ...

  • Enterasys Networks VH-8G-L3 - page 12

    9033705-01 2 Inspecting Your Shipment .......................................... 20 Installation................................................................... 20 Desktop or Shelf Installation ...................................... 21 Rack Installation ......................................................... 21 Power on ....................... ...

  • Enterasys Networks VH-8G-L3 - page 13

    3 9033705-01 Preface Purpose This guide provides information about the features and applications of the Enterasys Networks Vertical Horizon VH-8G-L3 layer 3 switch. Audience This guide is intended for Ethernet Local Area Network (LAN) administrators and Management Information Systems (MIS) personnel with the following background: • Working knowle ...

  • Enterasys Networks VH-8G-L3 - page 14

    9033705-01 4 Keyboard Entries This guide uses the following conventions for keyboard entries: • When you read “enter”, type the text and press the [Enter] key. • Example: Enter the Gateway IP address and press the [Enter] key. • When you read “select”, highlight the menu item and press the [Enter] key. Other Conventions This guide use ...

  • Enterasys Networks VH-8G-L3 - page 15

    5 9033705-01 mounting instructions. Instru ctions for making connections and powering up the Switch are provided as well. Chapter 3. Connecting the Switch: This describes how to connect the VH-8G-L3 to your Ethernet network, including connecting the Switch to an end node and connecting the Switch to hub or switch. Appendix A. Technical Specificatio ...

  • Enterasys Networks VH-8G-L3 - page 16

    6 9033705-01 Product Overview This chapter provides the following information: • Product Description • Features • Front and Rear Panel Component Descriptions • Feature Summaries • Application Example Description This section describes Layer 3 functionality and Layer 2 and Layer 3 features of the VH-8G-L3. Some background information about ...

  • Enterasys Networks VH-8G-L3 - page 17

    7 9033705-01 The VH-8G-L3 can be thought of as eight Gigabit Ethernet Layer 2 switching domains with a wire-speed router between each domain. It can be deployed in a network between a traditional router and the intranetwork. The traditional router and its associated WAN interf ace would then handle routing between the intranetwork and the WAN (the ...

  • Enterasys Networks VH-8G-L3 - page 18

    9033705-01 8 traditional collapsed backbone router. The VH-8G-L3 Layer 3 switch communicates with a WAN router using a standard Gigabit Ethernet port. Multiple VH-8G-L3 switches can also be linked. Features The VH-8G-L3 was designed for easy installation and high performance in an environment where traffic on the network and the number of users inc ...

  • Enterasys Networks VH-8G-L3 - page 19

    9 9033705-01 • 8K active MAC address entry t able per device with automatic learning and aging (10 to 9999 seconds). • 512 KB packet buffer per device. • Broadcast and Multicast storm filtering. • Supports Port Mirroring. • Supports Port Trunking – up to four trunk groups may be set up. One trunk group can have from two to eight ports. ...

  • Enterasys Networks VH-8G-L3 - page 20

    9033705-01 10 • Supports PIM Dense Mode (dra ft-ietf-pim-v2-dm-03.txt). • Supports DVMRP (draft-ietf-idmr-dvmrp-v3-09.txt). • Supports Username to IP address mapping. • Supports IP multi-netting. • Supports IP packet de-fragmentation. • Supports Path MTU discovery. • Supports 802.1D frame support. Traffic Classification and Prioritiza ...

  • Enterasys Networks VH-8G-L3 - page 21

    11 9033705-01 • Built-in SNMP management:  Bridge MIB (RFC 1493)  RMON MIB (RFC 1757) – 4 groups  MIB-II (RFC 1213)  Interface MIB ext. (RFC 2233)  CIDR MIB (RFC 2096) – excluding the IP Forwarding Table.  802.1p MIB (RFC 2674). • Supports Web-based management. • TFTP support. • BOOTP support. • IP filtering on the m ...

  • Enterasys Networks VH-8G-L3 - page 22

    9033705-01 12 theoretical throughput over 100Mbps Fast Ethernet and a one hundred-fold increase over 10M bps Ethernet. Since it is compatible with all 10Mbps and 100Mbps Ethernet environments, Gigabit Ethernet pr ovides a straightforward upgrade without wasting a company ’s existing investment in hardware, software, and trained personnel. Front P ...

  • Enterasys Networks VH-8G-L3 - page 23

    13 9033705-01 • The AC power connector is a standard three-pronged connector that supports the power cord. Plug-in the female connector of the provided power cord into this socket, and the male side of the cord into a power outlet. Supported input voltages range from 100 ~ 240 VAC at 50 ~ 60 Hz. Side Panels The right side panel of the Switch cont ...

  • Enterasys Networks VH-8G-L3 - page 24

    9033705-01 14 Figure 1-4. The LED indicators • Pow er This indicator on the front panel will light green approximately 2 seconds after the Switch is powered on to indicate the r eady state of the device. The LED will blink green while downloading new software for the Switch, or if the system’s configuration has changed and will light yellow whe ...

  • Enterasys Networks VH-8G-L3 - page 25

    15 9033705-01 network administrator can manage, control and monitor the switch from the console program. The VH-8G-L3 contains a CPU, memory for data storage, flash memory for configuration data, operational programs, and SNMP agent firmware. These components allow the switch to be actively managed and monitored from either the console port or the ...

  • Enterasys Networks VH-8G-L3 - page 26

    9033705-01 16 primary link. Once the Spanning Tree Protocol is configured and enabled, primary links are established and duplicated links are blocked automatically. The reactivation of the blocked links (at the time of a primary link failure) is also accomplished automatically – wi thout operator intervention. Port Trunking Port trunking is used ...

  • Enterasys Networks VH-8G-L3 - page 27

    17 9033705-01 Broadcast storms c onsist of broadcast packets that flood and/or are looped on a network causing noticeable performance degradation and in extreme cases, network failure. Broadcast storms c an be caused by malfunctioning NICs, bad cable connections and applications or protocols that generate broadcast traffic, among others. Broadcast ...

  • Enterasys Networks VH-8G-L3 - page 28

    9033705-01 18 Configuration File Name None Firmware File Name None Out-Of-Band Baud Rate 9600 RS232 Mode Console IP Address 0.0.0.0 Subnet Mask 0.0.0.0 Default Gateway 0.0.0.0 BootP Service Enabled TFTP Server IP Address 0.0.0.0 IGMP Time Out 260 secs IGMP Disabled Partition Mode Enabled Address table lock Disabled Device HOL Disabled Port HOL Enab ...

  • Enterasys Networks VH-8G-L3 - page 29

    19 9033705-01 19 9033705-01 Backpressure Disabled Port Lock Disabled Broadcast Storm Rising Action Do Nothing Broadcast Storm Falling Action Do Nothing Broadcast Storm Rising Threshold 128Kpps Broadcast Storm Falling Threshold < 128Kpps Community String “public”, “private” VLAN Mode IEEE 802.1Q Management In A VLAN All SNMP VLAN(802.1Q) ...

  • Enterasys Networks VH-8G-L3 - page 30

    9033705-01 20 2. Installation Inspecting Your Shipment Open the shipping carton of the Switch and carefully unpack its contents. The carton should contain the following items: • One VH-8G-L3 8-port Gigabit Ethernet Layer 3 Switch. • Mounting kit: 2 mounting brackets and screws. • Four rubber feet with adhesive backing. • One AC power cord. ...

  • Enterasys Networks VH-8G-L3 - page 31

    21 9033705-01 Desktop or Shelf Installation When installing the Switch on a desktop or shelf, the rubber feet included with the device should first be attached. Attach these cushioning feet on the bottom at each corner of the device. Allow adequate space for ventilation between the device and the objects around it. Figure 2-1. Installing rubber fee ...

  • Enterasys Networks VH-8G-L3 - page 32

    9033705-01 22 Figure 2-2B. Installing the Sw itch on an equipment rack Power on The VH-8G-L3 can be used with AC power supply 100-240 VAC, 50 - 60 Hz. Simply connect the power cord to the AC power connector located on the rear panel of the Switch and to AC power outlet. The Swit ch’s power supply will then adjust to the local power source automat ...

  • Enterasys Networks VH-8G-L3 - page 33

    23 9033705-01 3. Connecting The Switch This chapter describes how to connect the VH-8G-L3 to your Ethernet network. Switch to End Node A PC can be connected to the Swit ch via a fiber optic cable. The PC can be connected to any of the eight ports of the Switch. Figure 3-1. Example of the Sw itch connected to a PC or Workstation The LED indicators f ...

  • Enterasys Networks VH-8G-L3 - page 34

    9033705-01 24 Figure 3-2. Example of Sw itch to sw itch connection ...

  • Enterasys Networks VH-8G-L3 - page 35

    9033705-01 25 Appendix A. Technical Specifications General Standards: IEEE 802.3z 1000BASE-SX Gigabit Ethernet IEEE 802.1 P/Q VLAN IEEE 802.3x Full-duplex Flow Control ANSI/IEEE 802.3 auto-negotiation Protocols: CSMA/CD Data Transfer Rates: Gigabit Ethernet Half-duplex Full-duplex n/a 2000Mbps Topology: Star Network Cables: Fiber Optic: IEC 793-2:1 ...

  • Enterasys Networks VH-8G-L3 - page 36

    9033705-01 26 9033705-01 26 Storage Temperature: -40 to 70 degrees Celsius Humidity: Operating: 10% to 85% RH non-condensing Dimensions: 441 mm x 210 mm x 43 mm (1U), 19 inch rack-mount width Weight: 2.61 kg EMI: FCC Class A, CE Class A, VCCI Class A, BSMI Class A, C-Tick Class A FCC Part 15/IECES-003 (Canada), VCCI Class A ITE, EN55022/EN50082-1 o ...

  • Enterasys Networks VH-8G-L3 - page 37

    27 9033705-01 Performance Transmission Method: Store-and-forward RAM Buffer: 16 MB per device Filtering Address Table: 8K MAC address per device Packet Filtering/ Forwarding Rate: Full-wire speed for all connections 1,488,000 pps per port (for 1000Mbps) MAC Address Learning: Automatic update. Forwarding Table Age Time: Max age:10–9999 seconds Def ...

  • Enterasys Networks VH-8G-L3 - page 38

    28 9033705-01 Appendix B. Flow Control Flow control is a mechanism t hat allows you to protect the switch from overload conditions and to keep additional traffic off the network when excessive congestion will result. Flow Control for Half- and Full-Duplex Applications Each port of the switch has a transmit queue which buffers frames to be sent out ...

  • Enterasys Networks VH-8G-L3 - page 39

    9033705-01 29 Appendix C. Acronyms and Abbreviations Term Definition 10BASE-T 10 Mbps twisted-pair Ethernet 100BASE-TX 100 Mbps twisted-pair Fast Ethernet 100BASE-FX 100 Mbps fiber option Fast Ethernet 1000BASE-T 1000 Mbps twisted-pair Gigabit Ethernet 1000BASE-SX 1000 Mbps fiber option short-wavelength Gigabit Ethernet 1000BASE-LX 1000 Mbps fiber ...

  • Enterasys Networks VH-8G-L3 - page 40

    9033705 30 9033705 30 MDI Media Dependent Interface MDI Media Device Interface MIB Management Information Base RFC Request for Comment RMON Remote Monitoring RXD Receive Data.38 SNMP Simple Network Management Protocol TCP/IP Transmission Control Protocol/Internet Protocol TFTP Trivial File Transfer Protocol TXD Transmit Data UTP Unshielded Twisted ...

  • Enterasys Networks VH-8G-L3 - page 41

    9033705-01 31 Index AC inputs ................................ 25 AC power cord........................ 20 Accessory pack ....................... 20 Auto polarity detection ............. 8 Bridge MIB (RFC 1268) ......... 11 Broadcast domains .................. 16 Broadcast storm s ..................... 17 Connections Switch to End Node ........... ...

Manufacturer Enterasys Networks Category Switch

Documents that we receive from a manufacturer of a Enterasys Networks VH-8G-L3 can be divided into several groups. They are, among others:
- Enterasys Networks technical drawings
- VH-8G-L3 manuals
- Enterasys Networks product data sheets
- information booklets
- or energy labels Enterasys Networks VH-8G-L3
All of them are important, but the most important information from the point of view of use of the device are in the user manual Enterasys Networks VH-8G-L3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Enterasys Networks VH-8G-L3, service manual, brief instructions and user manuals Enterasys Networks VH-8G-L3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Enterasys Networks VH-8G-L3.

A complete manual for the device Enterasys Networks VH-8G-L3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Enterasys Networks VH-8G-L3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Enterasys Networks VH-8G-L3.

A complete Enterasys Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Enterasys Networks VH-8G-L3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Enterasys Networks VH-8G-L3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Enterasys Networks VH-8G-L3, that we can find in the current document
3. Tips how to use the basic functions of the device Enterasys Networks VH-8G-L3 - which should help us in our first steps of using Enterasys Networks VH-8G-L3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Enterasys Networks VH-8G-L3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Enterasys Networks VH-8G-L3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Enterasys Networks VH-8G-L3?

Use the form below

If you did not solve your problem by using a manual Enterasys Networks VH-8G-L3, ask a question using the form below. If a user had a similar problem with Enterasys Networks VH-8G-L3 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)