Manual Zephyr ASL-E48ASX

23 pages 2.07 mb
Download

Go to site of 23

Summary
  • Zephyr ASL-E48ASX - page 1

    ww w .zeph yronline .com Sur face Is. ASL-E42ASX ASL-E48ASX RANGE HOOD - Installation instructions ...

  • Zephyr ASL-E48ASX - page 2

    ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 23 CAMP ANA EXTRACT OR A - Manual de utilización ...P ag. 45 CAPP A ASPIRANTE - istruzioni per l’uso ...P ag. 67 - 2 - ...

  • Zephyr ASL-E48ASX - page 3

    C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS ........................................................................................................... pag. 7 DUCTING C AL CULA TION SHEETS ............................................... ...

  • Zephyr ASL-E48ASX - page 4

    ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspec tors use . INST ALLER : Please leave these Instructions with this unit for the owner . OWNER : Please retain thes ...

  • Zephyr ASL-E48ASX - page 5

    settings. B. Always turn hood ON when cooking at high heat or when  ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or  lter . D. Use proper pan siz e. Alwa ys use cookware appropriat e for the siz e of the sur face ...

  • Zephyr ASL-E48ASX - page 6

    ww w .zeph yronline .com through the  ue (chimney) of fuel burning equipment to prev ent back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those published by the National F ire Pr otec tion Association (NFP A), and the American Society for Heating, Refrigeration and Air C onditioning Engineers ...

  • Zephyr ASL-E48ASX - page 7

    List of Materials Decorative Mesh F ilters Cont rol Blower Housing Light Bulbs Range Hood Body Duct Covers Suppor t F rame Assembly TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 D M4 x 9/16" 4 Duct Cover Ceiling Bracket - 7 - ...

  • Zephyr ASL-E48ASX - page 8

    ww w .zeph yronline .com Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet. - 8 - ...

  • Zephyr ASL-E48ASX - page 9

    Hood Speci cations front of hood side of hood top of hood - 9 - ...

  • Zephyr ASL-E48ASX - page 10

    ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of  re and electric shock, install this range - hood only with internal blow er models MT -020 provided with the kit cod CBI-600A. F or external and in-line blower prepar ation please turn ...

  • Zephyr ASL-E48ASX - page 11

    Installation - In ternal Blow er 6. Attach the 6 pin male molex connector from blower wir e to the 6 pin female molex con- nector located inside the blower housing . See Fi g. 6 7. Install the motor and bracket, inside the motor housing, c ompleting the installation using the other screws (6 type B) that hav e been sup - plied. ( T ot. 13 type B)Fi ...

  • Zephyr ASL-E48ASX - page 12

    ww w .zeph yronline .com Installation - External & In-Line Blow er Pr epar ation The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of  r e and electric shock, install this rangehood only with remote blow ers rated maximum 6.2 A. ...

  • Zephyr ASL-E48ASX - page 13

    Installation - External & In-Line Blow er Pr epar ation Note1 : A cable lock (not included) may be re- quired by local c odes. Please r eview local co- des for mor e information. 6. Reinstall the cov er on the motor housing by follo wing the instructions from step 2 in re- verse or der . 7. Attach 6 pin male molex connectors to 6 pin female mol ...

  • Zephyr ASL-E48ASX - page 14

    ww w .zeph yronline .com W ARNING FIRE HA ZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only . F asten all connections with sheet metal screws and tape all ...

  • Zephyr ASL-E48ASX - page 15

    Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking sur face. If a connecting duc t work c omposed of two par ts is used, the upper part must be placed outside the low er par t. Do not connect the range hood duc t to the same duct used to exhaust hot ai ...

  • Zephyr ASL-E48ASX - page 16

    ww w .zeph yronline .com Installation - Moun ting the R ange Hood 2. Secure the top support frame to the duct cover ceiling bracket b y using the (4 type B) screws. F ig. 10 3. P osition hole template on the ceiling paying attention that the arr ow is po- sitioned on the same side as the range hood controls . - Make 4 holes in the ceiling and drive ...

  • Zephyr ASL-E48ASX - page 17

    5. Inser t the bottom suppor t frame into the top support frame. F ig.12 Adjust height acc ording to y our in- stallation and secure the support frames together using (2 type B) screws per extension arm (8 total). F ig.13 6. Inser t the motor housing into the suppor t frame assembly and secure it using (8 type B) screws. F ig.14 7. Connect the equi ...

  • Zephyr ASL-E48ASX - page 18

    ww w .zeph yronline .com Installation - P ow er Supply C onnec tion GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y CONNECTION F or connec tion to the po wer supply ref er to the following: 8. Break ...

  • Zephyr ASL-E48ASX - page 19

    Installation - P ow er Supply C onnec tion 11. Replace the lid by f ollowing the instruc tions from st ep 9 in reverse or der , en- suring that the tab on the lid is within the enclosure . 12. Having connected the equipment to the po wer supply , you can now continue with the ceiling mounting instructions. 13. Secure the corr ect size duc ting f or ...

  • Zephyr ASL-E48ASX - page 20

    ww w .zeph yronline .com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the r egularity of m ...

  • Zephyr ASL-E48ASX - page 21

    List of P ar ts and A c cessories DESCRIPTION HOOD P ART# REPLA CEMENT P ARTS Light Bulb GU4, 20W (each) ASL Z0B0030 OPTIONAL A CCESSORIES Recirculating Kit ASL ZRC-00SL Replacement Char coal F ilt ers ASL Z0F-00A C Duct Cover Extension (12” ceiling) ASL Z1C-00SL T o order parts, visit us online at http://store .zephyronline .com or call us at 1. ...

  • Zephyr ASL-E48ASX - page 22

    ww w .zeph yronline .com - 22 - ...

  • Zephyr ASL-E48ASX - page 23

    3LIK0510 ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ASL-E48ASX can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ASL-E48ASX manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ASL-E48ASX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ASL-E48ASX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ASL-E48ASX, service manual, brief instructions and user manuals Zephyr ASL-E48ASX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ASL-E48ASX.

Similar manuals

A complete manual for the device Zephyr ASL-E48ASX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ASL-E48ASX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ASL-E48ASX.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ASL-E48ASX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ASL-E48ASX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ASL-E48ASX, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ASL-E48ASX - which should help us in our first steps of using Zephyr ASL-E48ASX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ASL-E48ASX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ASL-E48ASX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ASL-E48ASX?

Use the form below

If you did not solve your problem by using a manual Zephyr ASL-E48ASX, ask a question using the form below. If a user had a similar problem with Zephyr ASL-E48ASX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)