  • Soehnle 2761 - page 1

    2761 Getting Started and Operating Instructions 470.620.022 Printed in Germany 2/1998 Subject to technical modifications ...

  • Soehnle 2761 - page 2

    _ Getting started 1 Set up the weighing platform at the place requir ed Use the water level and the adjustable feet to ensure that the scale is positioned horizontally . Fit the indicator or mount on the wall using the bracket provided. Connect the device to the mains The scale is ready for use The order in which the scales can be connected Space f ...

  • Soehnle 2761 - page 3

    On - Off Switch on (only when the scales are not loaded) After the test routine, the main display is set to zero. The scales are r eady for use. Switching between the scales Higher resolution (hold down the key) Zero setting Gross weight Data-transmission (printer/EDP) Switching between kg and lb Enter organisational data Component weighing Ta r e ...

  • Soehnle 2761 - page 4

    An acoustic signal confirms that the entry is correct Incorrect entries ar e indicated by means of five acoustic signals in swift sucession. Please check that your entry is correct. If necessary , cancel the command sequence by pressing the ”CI” key . Loading values Loading the value which is in the secon- dary display or which has been entered ...

  • Soehnle 2761 - page 5

    _ Display symbols main display secondary display 4 Zero message Standstill indication Active range in the case of multi-range scales. Percentage display Empty message Set points activated Gross weighing Net weighing T ar e display When battery is used (accessories): charge level Status switching and checking T otals memory Active scale Components w ...

  • Soehnle 2761 - page 6

    If the tare weight is unknown Determine the tare of the empty container Scales are r eady to perform net weighing If necessary , clear the tare after unloading the scale If the tare weight is known Place the filled container on the scale. Enter the tare weight in kg using the numeric keyboard. Confirm your entry by pressing the ”T” function key ...

  • Soehnle 2761 - page 7

    _ T otalling weights 6 T ar e the container if necessary . Place the items to be weighed on the scale. T ransfer the weight value to the totals memory . T ake the items take weighed of f the scale. Clear the tare if necessary If necessary , enter a new tare. Place the next items to be weighed on the scale. T ransfer the weight value to the totals m ...

  • Soehnle 2761 - page 8

    _ Weighing using the r emoval method _ *see component weighing 7 Place the filled container on the scale. If the tare is known , enter it manually if necessary and tare the weight. If it is important to determine the weight of the remainder: T ransfer the weight value to the totals memory . Press function key ”T”. The overall weight appears as ...

  • Soehnle 2761 - page 9

    _ Components weighing 8 T ar e the container if necessary Place the items to be weighed on the scale. T ransfer the weight value to the component weighing memory . The K-mode is indicated by an arrow . Place the next items to be weighed on the scale. T ransfer the weight value to the commission memory , etc. Place the next items to be weighed on th ...

  • Soehnle 2761 - page 10

    _ Switching and checking in the weighing mode 9 Set points (limit values) can only be set in weighing and counting mode. 3 memories for limit values are available for each connected scale: Entry must be additive, i.e. the weight of first limit value should be added to the second. Limit values affect the net weight. Loading memory Enter the value fo ...

  • Soehnle 2761 - page 11

    _ Switching and checking in the counting mode 10 Loading memory Enter number of pieces for set point with the numeric keyboard. Press the ”Ld” command key , followed by the number of the memory . Confirm your entry by pressing the function key . Memories 2 and 3 are enter ed and displayed in the same way . Recalling of stored values Press the ? ...

  • Soehnle 2761 - page 12

    _ Counting 11 Switch the scale to counting mode. Determining the refer ence weight T ar e the empty container if necessary . Place the number of items requested by the scale or enter the refer ence number of items requir ed by the numerical key board, take over with key , place entered number of items on the scale and press the ” ” function key ...

  • Soehnle 2761 - page 13

    _ T otalling quantities Determine the number of pieces. T ransfer this to the totals memory (in the secondary display) Remove the items from the scale. Clear the tare if necessary . Determine a new tare if necessary . Place the next quantity on the scale. T ransfer it to the totals memory , etc. Known quantities can be entered manually using the nu ...

  • Soehnle 2761 - page 14

    _ Removal method 13 Unknown number of pieces and item weight Determine the number of pieces(without tare) T o determine the r emaining number of pieces: transfer the number of pieces to the totals memory . Set the display to zero by pr essing the ”T” funktion key . The removal of items is indicated by a minus sign. Press the ”+” function ke ...

  • Soehnle 2761 - page 15

    _ Printing Key functions Single print Print - add to totals memory Print totals and clear memory Print - add to component weighing memory Print totals and clear memory Entering organisational data A 40- digit number can be assigned to each memory of the three organisational data memories. Enter the data using the numeric keyboard. Press the ”Ld? ...

  • Soehnle 2761 - page 16

    Activating user modification Press the ”i” key and ”On/Of f” at the same time. User modification functions Calibration step selection, forwards Calibration step selection, backwards Moving the tens column forward within a program step, fr om left to right Moving pre-assigned values forwar d Confirm and transfer the value of the main indicat ...

  • Soehnle 2761 - page 17

    Always column 00 Positioning on the right side 00XX B XX Gross weight 15 G XXXXX,XX <Unit> 01XX D XX Date 8 XX.XX.XX 02XX d XX Date 1x 8 for pressing tke key just once 03XX E XX Orga-data 1 No. 1 XXX... max. 39 pos. 04XX e XX Titel Org. 1 blank 05XX F XX Orga-data 2 No. 2 XXX... max. 39 pos. 06XX f XX Titel Org. 2 blank 07XX G XX Orga-data 3 ...

  • Soehnle 2761 - page 18

    Indicator An acoustic signal confirms that entry was correct Incorrect entries ar e indicated by 5 acoustic signals in swift succession. The scale sets the value zero automatically when it is switched on. If the scales are outside the set tolerance range, -0- is displayed. Underload: only the bottom horizontal lines appear on the display . Overload ...

  • Soehnle 2761 - page 19

    18 _ T echnical information • The housing is made from pr essure-moulded, powder -coated aluminium (RAL 9006) • Dimensions 258 x 193 x 73 mm • Protection type IP 65, dust pr oof and splash-proof • Operated by means of a tactile keypad with acoustic acknowledgement • Mains operation with power supply unit, 230 V 50-60Hz, approx. 20V A • ...

Manufacturer Soehnle Category Scale

Documents that we receive from a manufacturer of a Soehnle 2761 can be divided into several groups. They are, among others:
- Soehnle technical drawings
- 2761 manuals
- Soehnle product data sheets
- information booklets
- or energy labels Soehnle 2761
All of them are important, but the most important information from the point of view of use of the device are in the user manual Soehnle 2761.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Soehnle 2761, service manual, brief instructions and user manuals Soehnle 2761. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Soehnle 2761.

A complete manual for the device Soehnle 2761, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Soehnle 2761 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Soehnle 2761.

A complete Soehnle manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Soehnle 2761 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Soehnle 2761, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Soehnle 2761, that we can find in the current document
3. Tips how to use the basic functions of the device Soehnle 2761 - which should help us in our first steps of using Soehnle 2761
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Soehnle 2761
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Soehnle 2761 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Soehnle 2761?

Use the form below

If you did not solve your problem by using a manual Soehnle 2761, ask a question using the form below. If a user had a similar problem with Soehnle 2761 it is likely that he will want to share the way to solve it.

Copy the text from the picture