    CAUTIONS AND W ARNINGS . . . . . . . . . . 2 SYSTEM COMP A TIBILITY . . . . . . . . . . . . 3 FEA TURES . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS YOU MA Y NEED . . . . . . . . . . . . . . 4 MOUNTING LOCA TION . . . . . . . . . . . . . . 5 REMOVE OLD THERMOST A T . . . . . . . . . . 5 INST ALL THERMOST A T BASE . . . . . . . . . 6 WIRING ...

  • Lux Products P722Ub - page 2

    • This thermostat requires batteries to opera te and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell ® or Energizer ® alkaline batteries ONL Y for all LUXPRO thermostats requiring batteries. BE SURE TO CHANGE THE BA TTERIES A T LEAST ONCE A YEAR, or whenever you se ...

  • Lux Products P722Ub - page 3

    S ETBACK HO LD S E T R U N D AY/ T IM E T EM P P RO G S PE C P RO G F ILT / ENR GY T E MP E RAT U RE H E AT O FF C OO L F A N A U TO O N C O PY / E ME R N EX T LCD Display Screen P722Ub UP / DOWN Buttons Set Slide Switch Fan Mode Switch System Mode Switch The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combi ...

  • Lux Products P722Ub - page 4

    • 1 or 2-Heat / 1 or 2-Cool, 7-day programming • Universal Compatibility for all system types • Each day of the week can be programmed separately • Exclusive LUX ® Speed Slide T M for easy programming • User -selectable periods per day (2 or 4) • User -selectable programmable or non-programmable operation • LuxLight ® EL (Electro-Lu ...

  • Lux Products P722Ub - page 5

    On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.5m) above the floor . 2. Do not locate the thermostat where air circulation is poor such as in a ...

  • Lux Products P722Ub - page 6

    1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. F ill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’ s normal opera tion. 3. Separate new thermostat housing using your thumb and index finger . Provide pressure in opposite directions to ...

  • Lux Products P722Ub - page 7

    WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSIST ANCE” section of this manual, and contact us before removing any of your existing thermostat wiring. • All of t ...

  • Lux Products P722Ub - page 8

    8 #1 CONVENTIONAL: HEA TING ............................................................9 1-ST AGE OR 2-ST AGE 2 , 3 , 4 , 5 W I R E S #2 CONVENTIONAL: HEA TING .......................................................... 1 0 3-WIRE ZONE V AL VE 3, 4 WIRES #3 CONVENTIONAL: COOLING .......................................................... 1 1 1-ST AG ...

  • Lux Products P722Ub - page 9

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G W1 4 W B* W2 RH V R W1 A Y2 O B W2 C G Y1 RC RH 1-ST AGE OR 2-STAGE, HEA TING ONL Y (INCLUDING MILLIVOL T) (2-WIRE HEA T USE “RH” & “W1”) Factory RH-RC Jumper Wire Installed #1 2, 3, 4, 5 WIRES C H EATE R S T AG E 1 S T AG E 2 FAN SYSTEM 24V TR ...

  • Lux Products P722Ub - page 10

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X W1 4 W B* A RH V R W1 A Y2 O B W2 C G Y1 RC RH HOT WA TER HEA TING ONL Y (WITH A 3-WIRE ZONE V AL VE) Factory RH-RC Jumper Wire Installed #2 C SYSTEM 24V TRANSFORMER SYSTEM COMMON OPEN = Heat On CLOSE = Heat Off 3 -W I RE ZO N E VA LVE O PE N C LOS E 3, 4 WIRE ...

  • Lux Products P722Ub - page 11

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G Y1 6 Y B* Y2 RC V R W1 A Y2 O B W2 C G Y1 RC RH 1-ST AGE OR 2-STAGE, COOLING ONL Y Factory RH-RC Jumper Wire Installed #3 C A IR CO ND I TI O N ER S T AG E 1 S T AG E 2 FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON 3, 4, 5 WIRES O P T I O N A L 11 ...

  • Lux Products P722Ub - page 12

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC RH RC V R Y1 6 Y X F G W1 4 W B* W1 A Y2 O B W2 C G Y1 RC RH CONVENTIONAL (NON HEA T PUMP) 1-ST AGE HEATING AND 1-ST AGE COOLING Factory RH-RC Jumper Wire Installed #4 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON H EATE R AIR CONDITIONER 4, 5 WIRES O P T I O N A L ...

  • Lux Products P722Ub - page 13

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC Y1 6 Y X F G W1 4 W B* W2 RH V R Y2 W1 A Y2 O B W2 C G Y1 RC RH CONVENTIONAL (NON HEA T PUMP) 2-ST AGE HEATING AND 2-ST AGE COOLING Factory RH-RC Jumper Wire Installed #5 C H EATE R S T AG E 1 S T AG E 2 FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON A IR CO ND I TI O ...

  • Lux Products P722Ub - page 14

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X B* C R V RH R V RC Y1 6 Y F G W1 4 W W1 A Y2 O B W2 C G Y1 RC RH CONVENTIONAL (NON HEA T PUMP) 1-STAGE HEA TING AND 1-ST AGE COOLING WITH TWO SEPARA TE 24V TRANSFORMERS Factory RH-RC Jumper Wire REMOVED #6 FAN H E A T 2 4 V T RA N S FO R ME R COOL 24V T RA N S ...

  • Lux Products P722Ub - page 15

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC RC RH V R Y1 6 Y F G O X B* W1 A Y2 O B W2 C G Y1 RC RH SINGLE-ST AGE HEAT PUMP SYSTEM WITH NO AUX OR EMERGENCY HEA T Factory RH-RC Jumper Wire Installed CUSTOMER INST ALLED Y1-W1 Jumper Wire #7 C FAN SYSTEM 24V TRANSFORMER R EV E RS I N G VALVE SYSTEM COMMON HE ...

  • Lux Products P722Ub - page 16

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC RC RH V R Y1 6 Y X B* C W3 W1 W W2 F G O W1 A Y2 O B W2 C G Y1 RC RH 2-HEA T / 1-COOL, HEAT PUMP SYSTEM WITH AUX AND EMERGENCY HEA T #8 FAN SYSTEM 24V TRANSFORMER R EV E RS I N G VALVE AU X / EM E RG . H EAT SYSTEM COMMON HEA T PUMP 5, 6 WIRES O P T I O N A L ** ...

  • Lux Products P722Ub - page 17

    INST ALL BA TTERIES INTO THERMOST A T : Install two brand new Energizer ® o r DURACELL ® “AA ” size alkaline (only) batteries, into the thermosta t’ s battery compartment. Ensure the batteries are installed in the proper direction. These items below are all located behind the door on the front of the thermostat. T o open the door , pull out ...

  • Lux Products P722Ub - page 18

    UP / DOWN BUTTONS: The UP and DOWN buttons are used to adjust any item that can be changed by the user . Examples are the set temperatures, clock times, and days of the week. In many cases, an item may be flashing if it can currently be adjusted. HOLD BUTTON: This button activates and deactiva tes the manual T emperature Hold feature, and is also u ...

  • Lux Products P722Ub - page 19

    ITEM #03 (THERMOST A T TYPE): [PROGRAMMABLE, default] Use this setting for following a daily program routine. [MANUAL] This setting omits the program routine and operates as a manual style non-programmable thermostat. This is very basic and only shows the room tempera ture and set temperature on the screen, with no clock. ITEM #04 (PERIOD QUANTITY) ...

  • Lux Products P722Ub - page 20

    ITEM #08 (DELA Y TIME): [5, default] Thermostat waits 5 minutes before turning the system back on after it was last run. This internal delay prevents rapid cyc ling and provides equipment protection. The 5 minute setting is fine for most applications. [2] Same operation as above but reduced to 2 minutes between state changes. ITEM #09, #10, #11 (SY ...

  • Lux Products P722Ub - page 21

    SET D A Y AND TIME: Place the Set Slide Switch into the DA Y/TIME position. With the day flashing, press UP or DOWN to set the day of the week. Press NEXT and the clock time will start flashing. Use UP or DOWN to set the time, making sure the AM/PM indication is correct. Holding the UP or DOWN buttons will make the clock digits scroll rapidly . Ret ...

  • Lux Products P722Ub - page 22

    prevent damage to the heat pump if outside temperatures are belo w the manufacturer’ s recommendations. As ever y heat pump has different operating characteristics, you should refer to your heat pump literature to determine when to disable the heat pump and run in Emergency Heat mode. LCD DISPLA Y BACKLIGHT : The display screen is lighted to assi ...

  • Lux Products P722Ub - page 23

    By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DA Y , EVE, and NITE. Each period ends at the start time of the following period. The heat programs are set in HEA T mode, and the cool programs are set in COOL mode. NOTE: If the thermostat is configured to use only 2 periods per day instead of ...

  • Lux Products P722Ub - page 24

    may continue to perform short single presses of the COPY/EMER button to proceed with copying to the remaining days, one after the other (specific days may be skipped by pressing the UP button to advance past them when they are flashing in the “copy to” location). T o exit the Copy feature, and return to the regular temperature program screen, p ...

  • Lux Products P722Ub - page 25

    TO ST ART A SETBACK: Ensure that the System Mode switch is in either the Heat or Cool position, and that the Set Slider is in the RUN position. Press and hold the SETBACK button for at least 2 seconds. The screen will change and show the words “HOURS LEFT” and “OVERRIDE”, along with two digits. Use the UP/DOWN buttons to set the duration fo ...

  • Lux Products P722Ub - page 26

    TO SET THE SPECIAL PROGRAM V ALUES: Move the Set Slide switch to the SPEC PROG position. The screen will display “S-PROG”. Use the UP/DOWN buttons to adjust the start time for the MORN period, then press the NEXT button to advance. Use the UP/DOWN buttons to adjust the set temperature for the MORN period, then press the NEXT button to advance. ...

  • Lux Products P722Ub - page 27

    TO SET THE HEA T LIMIT STOP: Place the System Mode switch in the OFF position, and the Set Slide switch in the RUN position. Press and hold the UP button while sliding the System Mode switch from OFF to HEA T . The words “CODE” and “T–STOP” will appear at the top of the screen, along with two digits. Use the UP/DOWN buttons to select the ...

  • Lux Products P722Ub - page 28

    KEYP AD LOCKOUT : Y ou can lock the front panel buttons to prevent unauthorized tampering of your thermostat settings. NOTE: These keypad lock instructions need to be performed in a timely manner , as the thermostat will timeout and automatically exit the keypad lock screens and return to the Normal Run screen after approximately 10 seconds without ...

  • Lux Products P722Ub - page 29

    AIR FIL TER MONITOR: In most systems that use a blower fan and air ducts, there is an air filter that is either replaceable or requires cleaning. The filter is usually located in the air handler , where the blower fan is. This thermostat feature assists you with keeping track of proper maintenance and/or periodic replacement intervals for your syst ...

  • Lux Products P722Ub - page 30

    Usage, and the T otal Cumulative Usage. NOTE: For the T otal Cumulative Usage, the timer will record up to a maximum of 99 hours and 59 minutes, then the display will change to “HHHH” for hours only , without the colon in the center . Return the Set Slide switch to the RUN position when you are finished. TO RESET THE HEA T ENERGY USAGE: While v ...

  • Lux Products P722Ub - page 31

    SOFTWARE RESET : A Software Reset is used to erase ALL heating and cooling temperature programs, and to return all user -adjustable software settings back to their original factory default values. T o perform a Software Reset, first ensure that the thermostat’ s Keypad Lockout is not enabled and then move the System Mode switch to the OFF positio ...

  • Lux Products P722Ub - page 32

    This thermostat is powered by two “AA ” Alkaline batteries. The batteries should be replaced A T LEAST once per year to ensure reliable operation (or sooner if the phrase “LO BA TT” appears in the display screen). The batteries are located on the back of the thermostat’ s circuit board. The front portion of the thermosta t can be removed ...

  • Lux Products P722Ub - page 33

    If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our T echnical Assistance department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday . Y ou can also receive techn ...

  • Lux Products P722Ub - page 34

    Mercury is considered to be a hazardous material. If this product is replacing a thermostat that contains mercur y in a sealed tube, contact your local waste management authority for instructions regarding recycling and proper disposal. It may be unlawful in your state to place it in the trash. 34 MERCURY W ARNING AND RECYCLING NOTICE: Mt. Laurel, ...

Manufacturer Lux Products Category Thermostat

Documents that we receive from a manufacturer of a Lux Products P722Ub can be divided into several groups. They are, among others:
- Lux Products technical drawings
- P722Ub manuals
- Lux Products product data sheets
- information booklets
- or energy labels Lux Products P722Ub
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lux Products P722Ub.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lux Products P722Ub, service manual, brief instructions and user manuals Lux Products P722Ub. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lux Products P722Ub.

A complete manual for the device Lux Products P722Ub, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lux Products P722Ub by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lux Products P722Ub.

A complete Lux Products manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lux Products P722Ub - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lux Products P722Ub, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lux Products P722Ub, that we can find in the current document
3. Tips how to use the basic functions of the device Lux Products P722Ub - which should help us in our first steps of using Lux Products P722Ub
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lux Products P722Ub
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lux Products P722Ub in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lux Products P722Ub?

Use the form below