    N8406-022A 1Gb Intelligent L2 Switch Smart Panel Reference Guide Part number: 856-126757-406-00 First edition: July 2008 ...

  • NEC N8406-022A - page 2

    2 Legal notices © 2008 NEC Corporation The information contained herein is subject to change without notice. The only wa rranties for NEC products and services are set forth in the express warranty statements accompanying such products and serv ices. Nothing herein should be construed as constituting an addi tional warranty. NEC shall not be liabl ...

  • NEC N8406-022A - page 3

    SmartPanel 3 Contents SmartPanel Introduction ............................................................................................................................................................. 5 Additional references .......................................................................................................................... ...

  • NEC N8406-022A - page 4

    SmartPanel 4 Show last 100 syslog messages ..................................................................................................................... 38 System user information ................................................................................................................................. 38 Layer 2 information ......... ...

  • NEC N8406-022A - page 5

    SmartPanel 5 SmartPanel Introduction The 1Gb Intelligent L2 Switch provides t wo switch mo des: The conventional L2 s witch mode, and SmartPanel mode. The switch can store up to two different soft ware image, called imag e1 and image2. Normally, the conventional L2 switch software image is stored in imag e1, and the SmartPane l soft ware is stored ...

  • NEC N8406-022A - page 6

    SmartPanel 6 Management Network The 1Gb Intelligent L2 Switch is a S witch Module within the Blade Enclosure. T he Blade Enclosure includ es an Enclosure Manager Card which manages the modules and CPU Blad es in the enclosure. The 1Gb Intelligent L2 Switch communicat es with the En closure Manager Card through it s internal management port (port 19 ...

  • NEC N8406-022A - page 7

    SmartPanel 7 Setting an IP address To access the switch via a Telnet, an SSH connection, or an HTT P connection, you need to have an Int ernet Protocol (IP) address set for the switch. You can assign t he IP address only to the manag ement interfac e (interface 256), associated with port 19. The managem ent interface requests its IP address from a ...

  • NEC N8406-022A - page 8

    SmartPanel 8 Table 3 User access levels User account Description and tasks performed user The user has no direct responsibilit y for switch management. He or she can view all switch status information and statistics, but cannot make any configur ation changes to the switch. The user account is enabled by default, and the defau lt password is user . ...

  • NEC N8406-022A - page 9

    Browser-based interface 9 Browser-based interface Introduction This chapter explains ho w to access the switch browse r-based interface (BBI) for t he SmartPanel and config ure the swi tch. Requirements To use the browser-based interf ace, you need the follo wing: • PC or workstation with network access to the switch • Frame-capable Web-bro wse ...

  • NEC N8406-022A - page 10

    Browser-based interface 10 If the switch IP interface address has a name on your local domain name s erver, you can enter the name instead. Using Internet Explor er, you can ent er the follo wing: 3. Log in to the switch. If your switch and browser are properly configured, you will be asked to enter a password. Enter the account name and pass word ...

  • NEC N8406-022A - page 11

    Browser-based interface 11 There are three main regions on the screen. • The Port Status Area is used to view port status. Click a port icon to vie w details. • The Menu Area is used to select parti cular items or features to act upon. • The Configuration Area is use d to configure selected items. Port Status Area The Status Area contains por ...

  • NEC N8406-022A - page 12

    Browser-based interface 12 Displays I/O bay number Click to expand or contact Click to select Menu Area The Menu Area is used for selecting a partic ular feature to act upon. Configuration forms for the selected item appear in the Configuration Window. The Menu Area contains a tree of feature folders a nd names. Click on System Settings to open it ...

  • NEC N8406-022A - page 13

    Browser-based interface 13 Port Group Mapping SmartPanel ports can be combined into Port Groups. Up to five Port Groups are availab le in the SmartPanel. A Spare Ports Group is available for unused ports. VLANs and Link Aggregation Groups (tr unks ) are config ured automatically fo r each Port Group. No network loops are allowed in the configurati ...

  • NEC N8406-022A - page 14

    Browser-based interface 14 In this example, Port 1-4, 20-21 are assigned to Group1, and Port 5-8, 22- 23 are ass igned to Group2. The others are assigned to Spare Ports Group. Internal Port Settings On the BBI, choose Internal Port Settings to enable or disable the serv er blad e port. ...

  • NEC N8406-022A - page 15

    Browser-based interface 15 External Port Settings On the BBI, choose External Port Setti ngs to configure the external port. The following table describes the external port configuration. Table 7 External Port Settings Command Description Port Name Sets a name for the port. The assigned port name appears ne xt to the port number on some information ...

  • NEC N8406-022A - page 16

    Browser-based interface 16 VLAN Virtual LANs (VLANs) are commonly used to split up gr ou ps of network users into manageable br oadcast domains, to create logical segmentation of workgroups, and to enforce security polici es among logical segments. T his s witch supports up to 1,000 VLANs per switch. Even though the ma xim um numb er of VLANs suppo ...

  • NEC N8406-022A - page 17

    Browser-based interface 17 Non-Default Virtual LANs On the BBI, choose Non-Default Virtual LANs to create VLANs and assign them to Port Groups. T he non-default VLAN ID is placed in the frame header of a packet in for watding from the port. The following describes the steps to add VLAN ID. 1. Click Add VLAN to configure a ne w VLAN. 2. Enter a VLAN ...

  • NEC N8406-022A - page 18

    Browser-based interface 18 3. Select the corresponding radi o button to assign the VLAN to a Port Group. 4. Click Apply to make the changes active. Management On the BBI, choose System Settings > Management to c onfigure SNMP System Settings and System Log Server Settings. The following table describes the management configuration. Table 8 Manag ...

  • NEC N8406-022A - page 19

    Browser-based interface 19 Table 8 Management Command Description Facility of Secondary Server This option sets the fac ility level of the secondary syslog server displayed. The default is 0. Local User Administration On the BBI, choose System Settings > Local Us er Administration to configure the user. The following table describes the user con ...

  • NEC N8406-022A - page 20

    Browser-based interface 20 Remote User Administration On the BBI, choose System Settings > Remote User Admi nistration to configure the RADIUS server or the TACACS+ server. The following table descri bes the configurati on. Table 10 Remote User Administration Command Description Radius Radius disable/enable E nables or disables the Radius server ...

  • NEC N8406-022A - page 21

    Browser-based interface 21 Ti m e S e r v i c e s On the BBI, choose System Settings > Time Services to configure the NTP server. The following table descri bes the configurati on. Table 11 Time Services Command Description General Settings Current Date Configures the system date. Current Time Configures the system time using a 24-hour clock for ...

  • NEC N8406-022A - page 22

    Browser-based interface 22 T runking Trunk groups provide super- bandwidth, multi-link connecti ons bet ween SmartPanel or other trunk-cap able devices. A trunk group is a group of ports that act together, combini ng their bandwidth to create a singl e, larger virtual link. SmartPanel trunk groups are static link aggregati on groups that are comp a ...

  • NEC N8406-022A - page 23

    Browser-based interface 23 Trunk Group configuration On the BBI, choose System Settings > Uplink/Group to enabl e or disab le the Link Aggr egation Control P rotocol. When enabled, the exter nal ports are configured as a LAC P trunk group. When disabl ed , they are configured as a static trunk group. T he default is disabled. Failover The primar ...

  • NEC N8406-022A - page 24

    Browser-based interface 24 Failover configuration On the BBI, choose System Settings > Uplink/Group to conf igure the S witch Failover and Number of Links to Trigger Failover. IGMP Snooping IGMP Snooping allows the SmartPanel to for ward multicas t traffic only to those ports that request it. IGMP Snooping prevents multicast traffic from being f ...

  • NEC N8406-022A - page 25

    Browser-based interface 25 Boot Management On the BBI, choose System Settings > Boot Management to backup or restore the switch configuration , update the switch software image, or get dump file. The following table descri bes the configurati on. Table 12 Boot Management Command Description Reboot the Module button Reboots the switch. Next boot ...

  • NEC N8406-022A - page 26

    Browser-based interface 26 Table 12 Boot Management Command Description Put TS Dump Uploads the TS (tech support) dump file to the TFTP or FTP server specified in Remote File Name. Put Crash Dump Uploads the core (PANIC) dump fi le to the TFTP or FTP server specified in Remote Filename. Clear Crash Dump Deletes the core dump in flash memor y. IMPOR ...

  • NEC N8406-022A - page 27

    Command Line Interface 27 Command Line Interface Introduction The CLI is used for viewing switch information an d statis tics. In addition, t he administrator can use the CLI for performing all levels of switch configuration. To make the CLI easy to use, the various commands have been logically grouped into a series of menus and submenus. Each menu ...

  • NEC N8406-022A - page 28

    Command Line Interface 28 Global commands Some basic commands are recogniz ed throughout the menu hier arch y. These commands are useful for obtai nin g online Help, navigating throug h menus, and for app lying and saving configuratio n changes. For help on a specific command, type help. The follo wing screen displays: Global Commands: [can be issu ...

  • NEC N8406-022A - page 29

    Command Line Interface 29 Table 13 Global commands Command Action who Displays users who are logged in. Command line history and editing Using the command line i nter face, you can retrieve and modif y previously entered commands with just a few keystrokes. The following options are avail ab le glo bally at the command line: Table 14 Command li ne ...

  • NEC N8406-022A - page 30

    Command Line Interface 30 Command line interface shortcuts The following shortcuts allo w you to enter co mmands quickly and easil y. Command stacking As a shortcut, you can type multiple comman ds on a single line, separated by forward slas hes (/). You can conn ect as many commands as required to access the menu o ption that you want. For example ...

  • NEC N8406-022A - page 31

    Command Line Interface 31 Information Menu Introduction You can view configuration inf ormation for the switch in the user, operator, and admin istra tor command modes. This chapter discusses how to use the CLI t o displ ay switch information. Menu overview Command: /info [Information Menu] sys - System Information Menu l2 - Layer 2 Information Men ...

  • NEC N8406-022A - page 32

    Command Line Interface 32 System Information Menu Command: /info/sys [System Menu] snmpv3 - SNMPv3 Information Menu general - Show general system information log - Show last 100 syslog messages user - Show current user status dump - Dump all system information The following table describes the S ystem Information Menu options. Table 16 System Infor ...

  • NEC N8406-022A - page 33

    Command Line Interface 33 Table 17 SNMPv3 Information Menu options Command Usage dump Display s all the SNMPv3 information. SNMPv3 USM User Table information Command: /info/sys/snmpv3/usm usmUser Table: User Name Protocol -------------------------------- -------------------------------- adminmd5 HMAC_MD5, DES PRIVACY adminsha HMAC_SHA, DES PRIVACY ...

  • NEC N8406-022A - page 34

    Command Line Interface 34 SNMPv3 Access Table information Command: /info/sys/snmpv3/access Group Name Model Level ReadV WriteV NotifyV ---------- ------- ------------ --------- -------- ------- v1v2grp snmpv1 noAuthNoPriv iso iso v1v2only admingrp usm authPriv iso iso iso The access control sub system pr ovides aut horizati on servi ces. The vacmAc ...

  • NEC N8406-022A - page 35

    Command Line Interface 35 Table 22 SNMPv3 Community Table par ameters Field Description Name Displays the community string, wh ich represents the configuration. User Name Displays the User Security Model (USM) user name. Tag Displays the community tag. This tag specif ies a set of transport endpoints from which a command responder application accep ...

  • NEC N8406-022A - page 36

    Command Line Interface 36 SNMPv3 Notify Table information Command: /info/sys/snmpv3/notify Name Tag -------------------- -------------------- v1v2trap v1v2trap The following table describes the SNMPv3 N otify Table information. Table 25 SNMPv3 Notify Table Field Description Name The locally arbitrary, but unique identifier associated with this snmp ...

  • NEC N8406-022A - page 37

    Command Line Interface 37 System information Command: /info/sys/gen System Information at 6:56:22 Thu Jan 11, 2006 Time zone: Asia/Tokyo Blade Network Technologies 1Gb Intelligent L2 Switch, SmartPanel sysName: sysLocation: RackId: NEC01A 6X00125 RackName: Default_Rack_Name EnclosureSerialNumber: NEC01A 6X00125 EnclosureName: Default_Chassis_Name B ...

  • NEC N8406-022A - page 38

    Command Line Interface 38 Show last 100 syslog messages Command: /info/sys/log Date Time Severity level Message ---- ---- ----------------- ------- Jul 8 17:25:41 NOTICE system: link up on port 1 Jul 8 17:25:41 NOTICE system: link up on port 8 Jul 8 17:25:41 NOTICE system: link up on port 7 Jul 8 17:25:41 NOTICE system: link up on port 12 Jul 8 17: ...

  • NEC N8406-022A - page 39

    Command Line Interface 39 Layer 2 information Command: /info/l2 [Layer 2 Menu] fdb - Forwarding Database Information Menu trunk - Show Trunk Group information dump - Dump all layer 2 information The following table describes the Layer 2 Information menu options. Table 27 Layer 2 informatio n menu o ptions Command Usage fdb Displays the Forwarding D ...

  • NEC N8406-022A - page 40

    Command Line Interface 40 FDB information menu Command: /info/l2/fdb [Forwarding Database Menu] find - Show a single FDB entry by MAC address port - Show FDB entries on a single port vlan - Show FDB entries on a single VLAN state - Show FDB entries by state dump - Show all FDB entries The forwarding database (FDB) contains i nformation that maps th ...

  • NEC N8406-022A - page 41

    Command Line Interface 41 Trunk group information Command: /info/l2/trunk Trunk group 1, Enabled Protocol - Static port state: 20: forwarding 21: forwarding 22: forwarding 23: forwarding 24: forwarding When trunk groups are configure d, you can view the state of each port in the various trunk groups. Layer 3 information Command: /info/l3 [Layer 3 M ...

  • NEC N8406-022A - page 42

    Command Line Interface 42 ARP information Command: /info/arp [Address Resolution Protocol Menu] find - Show a single ARP entry by IP address port - Show ARP entries on a single port vlan - Show ARP entries on a single VLAN addr - Show ARP entries for switch's interface dump - Show all ARP entries The Address Resolution Protocol (ARP) infor mat ...

  • NEC N8406-022A - page 43

    Command Line Interface 43 IP information Command: /info/l3/ip Interface information: 1: 47.80.23.243 255.255.254.0 47.80.23.255, vlan 1, up Default gateway information: metric strict 4: 47.80.23.254, vlan 4095, up active The following interface and default gate way information is displayed: • Interface number • IP address • IP mask • IP bro ...

  • NEC N8406-022A - page 44

    Command Line Interface 44 Link status information Command: /info/link ------------------------------------------------------------------ Port Speed Duplex Flow Ctrl Link ---- ----- -------- --TX-----RX-- ------ 1 1000 full yes yes up 2 1000 full yes yes up 3 1000 full yes yes up 4 1000 full yes yes up 5 any any yes yes down 6 any any yes yes down 7 ...

  • NEC N8406-022A - page 45

    Command Line Interface 45 Group information Command: /info/group Group 1: Internal Ports: 1-16 External Ports: 20-24 Port VLAN ID: 1 Number of nondefault vlans in group: 0 VLANs: empty Default Group Vlan: 1 Trunk group 13: Enabled port state: 20: forwarding 21: forwarding 22: forwarding 23: forwarding 24: forwarding LACP Enabled IGMP Disabled Failo ...

  • NEC N8406-022A - page 46

    Command Line Interface 46 S tatistics Menu Introduction You can view switch performance statistics in the user , operator, and a dmi nistrator command modes. This chapter discusses how to use the CLI to display switch statistics. Menu information Command: /stats [Statistics Menu] port - Port Stats Menu clrports – Clear stats for all ports l2 - La ...

  • NEC N8406-022A - page 47

    Command Line Interface 47 Port Statistics Menu Command: /stats/port <port number> [Port Statistics Menu] brg - Show bridging ("dot1") stats ether - Show Ethernet ("dot3") stats if - Show interface ("if") stats ip - Show Internet Protocol ("IP") stats link - Show link stats clear - Clear all port stats T ...

  • NEC N8406-022A - page 48

    Command Line Interface 48 Ethernet statistics Command: /stats/port <port number>/ether Ethernet statistics for port 1: dot3StatsAlignmentErrors: 0 dot3StatsFCSErrors: 0 dot3StatsSingleCollisionFrames: 0 dot3StatsMultipleCollisionFrames: 0 dot3StatsLateCollisions: 0 dot3StatsExcessiveCollisions: 0 dot3StatsInternalMacTransmitErrors: 0 dot3Stat ...

  • NEC N8406-022A - page 49

    Command Line Interface 49 Table 37 Ethernet statistics for port Statistics Description dot3StatsInternalMacTransmitErrors A count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of ...

  • NEC N8406-022A - page 50

    Command Line Interface 50 Table 38 Interface statistics for port Statistics Description Errors—IfHCIn For packet-oriented interfaces, the number of inbou nd packets that contained errors preventing them from being deliver ed to a higher-layer protocol. For character-oriented or fixed-le ngt h interfaces, the number of inbound transmission units t ...

  • NEC N8406-022A - page 51

    Command Line Interface 51 Link statistics Command: /stats/port <port number> /link Link statistics for port 1: linkStateChange: 2 The following table describes the lin k statistics for a selected port: Table 40 Link statistics for port Statistic Description linkStateChange The total number of link state changes. Layer 2 statistics Menu Comman ...

  • NEC N8406-022A - page 52

    Command Line Interface 52 Layer 3 statistics Menu Command: /stats/l3 [Layer 3 Statistics Menu] ip - Show IP stats route - Show route stats arp - Show ARP stats icmp - Show ICMP stats tcp - Show TCP stats udp - Show UDP stats igmp - Show IGMP stats clrigmp - Clear IGMP stats ipclear - Clear IP stats dump - Dump layer 3 stats The following table desc ...

  • NEC N8406-022A - page 53

    Command Line Interface 53 Table 44 IP statistics Statistics Description ipInDiscards The number of input IP datagrams for which no problems were enco untered to prevent their continued processing, but which were discarded (for example, for lack of buffer space). This counter does not include any datagram s discarded while awaiting re-assembly. ipIn ...

  • NEC N8406-022A - page 54

    Command Line Interface 54 ICMP statistics Command: /stats/l3/icmp ICMP statistics: icmpInMsgs: 245802 icmpInErrors: 1393 icmpInDestUnreachs: 41 icmpInTimeExcds: 0 icmpInParmProbs: 0 icmpInSrcQuenchs: 0 icmpInRedirects: 0 icmpInEchos: 18 icmpInEchoReps: 244350 icmpInTimestamps: 0 icmpInTimestampReps: 0 icmpInAddrMasks: 0 icmpInAddrMaskReps: 0 icmpOu ...

  • NEC N8406-022A - page 55

    Command Line Interface 55 TCP statistics Command: /stats/l3/tcp TCP statistics: tcpRtoAlgorithm: 4 tcpRtoMin: 0 tcpRtoMax: 240000 tcpMaxConn: 512 tcpActiveOpens: 252214 tcpPassiveOpens: 7 tcpAttemptFails: 528 tcpEstabResets: 4 tcpInSegs: 756401 tcpOutSegs: 756655 tcpRetransSegs: 0 tcpInErrs: 0 tcpCurBuff: 0 tcpCurConn: 3 tcpOutRsts: 417 The followi ...

  • NEC N8406-022A - page 56

    Command Line Interface 56 UDP statistics Command: /stats/l3/udp UDP statistics: udpInDatagrams: 54 udpOutDatagrams: 43 udpInErrors: 0 udpNoPorts: 1578077 The following table describes the User Datagram Protocol (UDP) statistics: Table 49 UDP statistics Statistics Description udpInDatagrams The total number of UDP datagrams delivered to the switch. ...

  • NEC N8406-022A - page 57

    Command Line Interface 57 Management Processor statistics Command: /stats/mp [MP-specific Statistics Menu] i2c - Show i2c stats pkt - Show Packet stats tcb - Show All TCP control blocks in use ucb - Show All UDP control blocks in use cpu - Show CPU utilization The following table describes the MP -specific Statistics Menu options: Table 51 MP-speci ...

  • NEC N8406-022A - page 58

    Command Line Interface 58 TCP statistics Command: /stats/mp/tcb All TCP allocated control blocks: 10ad41e8: 0.0.0.0 0 <=> 0.0.0.0 80 listen 10ad5790: 47.81.27.5 1171 <=> 47.80.23.243 23 established The following table describes the Transmission Control Prot oc ol (TCP) control block (T CB) statistics shown in this example: Table 53 MP s ...

  • NEC N8406-022A - page 59

    Command Line Interface 59 NTP statistics Command: /stats/ntp NTP statistics: Primary Server: Requests Sent: 17 Responses Received: 17 Updates: 1 Secondary Server: Requests Sent: 0 Responses Received: 0 Updates: 0 Last update based on response from primary server. Last update time: 18:04:16 Tue Mar 13, 2006 Current system time: 18:55:49 Tue Mar 13, ...

  • NEC N8406-022A - page 60

    Command Line Interface 60 Configuration Menu Introduction The Configuration Menu is on ly available from an administr ator log in. It includes s ubmenus for configuring ever y aspect of the switch. Changes to confi guration are not active until explic itly applied. Changes ca n be sa ved to non- volatile memory (NVRAM). Menu information Command: /c ...

  • NEC N8406-022A - page 61

    Command Line Interface 61 Viewing pending changes You can view all pending confi gurati on changes by entering diff at an y CLI prompt: # diff You can view all pending confi gurati on changes that have been appl ied but not saved to flash memory by enterin g diff flash at any CLI prompt: # diff flash Applying pending changes To make your configurat ...

  • NEC N8406-022A - page 62

    Command Line Interface 62 System configuration Command: /cfg/sys [System Menu] syslog - Syslog Menu sshd - SSH Server Menu radius - RADIUS Authentication Menu tacacs+ - TACACS+ Authentication Menu ntp - NTP Server Menu ssnmp - System SNMP Menu access - System Access Menu watchdog - Watchdog Menu date - Set system date time - Set system time timezon ...

  • NEC N8406-022A - page 63

    Command Line Interface 63 Table 58 System Configurati on Men u options Command Usage cur Displays the current system parameters. System host log configuration Command: /cfg/sys/syslog [Syslog Menu] host - Set IP address of first syslog host host2 - Set IP address of second syslog host sever - Set the severity of first syslog host sever2 - Set the s ...

  • NEC N8406-022A - page 64

    Command Line Interface 64 Secure Shell Server configuration Command: /cfg/sys/sshd [SSHD Menu] interval– Set Interval for generating the RSA server key scpadm – Set SCP-only admin password hkeygen - Generate the RSA host key skeygen - Generate the RSA server key sshport - Set SSH server port number ena - Enable the SCP apply and save dis - Disa ...

  • NEC N8406-022A - page 65

    Command Line Interface 65 RADIUS server configuration Command: /cfg/sys/radius [RADIUS Server Menu] prisrv - Set primary RADIUS server address secsrv - Set secondary RADIUS server address secret - Set primary RADIUS server secret secret2 - Set secondary RADIUS server secret port - Set RADIUS port retries - Set RADIUS server retries timeout - Set RA ...

  • NEC N8406-022A - page 66

    Command Line Interface 66 TACACS+ server configuration Command: /cfg/sys/tacacs+ [TACACS+ Server Menu] prisrv - Set IP address of primary TACACS+ server secsrv - Set IP address of secondary TACACS+ server secret - Set secret for primary TACACS+ server secret2 - Set secret for secondary TACACS+ server port - Set TACACS+ port number retries - Set num ...

  • NEC N8406-022A - page 67

    Command Line Interface 67 IMPORTANT: If T ACACS+ is enabled, you must l ogin usin g TACACS+ authentication when connecting via the console or Telnet/SSH/HTT P/HTTPS. Backdoor for co nsole is always ena bled, so you can connect using notacacs and the administrator pass w ord even if the backdoor ( bckdoor ) or secure backdoor ( secbd ) are disabled. ...

  • NEC N8406-022A - page 68

    Command Line Interface 68 System SNMP configuration Command: /cfg/sys/ssnmp [SNMP Menu] snmpv3 - SNMPv3 Menu name - Set SNMP "sysName" locn - Set SNMP "sysLocation" cont - Set SNMP "sysContact" rcomm - Set SNMP read community string wcomm - Set SNMP write community string timeout - Set timeout for the SNMP state machin ...

  • NEC N8406-022A - page 69

    Command Line Interface 69 SNMPv3 configuration Command: /cfg/sys/ssnmp/snmpv3 [SNMPv3 Menu] usm - usmUser Table Menu view - vacmViewTreeFamily Table Menu access - vacmAccess Table Menu group - vacmSecurityToGroup Table Menu comm - community Table Menu taddr - targetAddr Table Menu tparam - targetParams Table Menu notify - notify Table Menu v1v2 - E ...

  • NEC N8406-022A - page 70

    Command Line Interface 70 SNMPv3 User Security Model configuration Command: /cfg/sys/ssnmp/snmpv3/usm < usm number > [SNMPv3 usmUser 1 Menu] name - Set USM user name auth - Set authentication protocol authpw - Set authentication password priv - Set privacy protocol privpw - Set privacy password del - Delete usmUser entry cur - Display current ...

  • NEC N8406-022A - page 71

    Command Line Interface 71 Table 67 SNMPv3 View Configuration Men u options Command Description del Deletes the vacmViewTreeFamily group entry. cur Displays the current vacmViewTreeFamily configuration. SNMPv3 View-based Access Control Model configuration Command: /cfg/sys/ssnmp/snmpv3/access < access number > [SNMPv3 vacmAccess 1 Menu] name - ...

  • NEC N8406-022A - page 72

    Command Line Interface 72 SNMPv3 Group configuration Command: /cfg/sys/ssnmp/snmpv3/group < group number > [SNMPv3 vacmSecurityToGroup 1 Menu] model - Set security model uname - Set USM user name gname - Set group name del - Delete vacmSecurityToGroup entry cur - Display current vacmSecurityToGroup configuration The following table describes ...

  • NEC N8406-022A - page 73

    Command Line Interface 73 SNMPv3 Target Address Table configuration Command: /cfg/sys/ssnmp/snmpv3/taddr < taddr number > [SNMPv3 snmpTargetAddrTable 1 Menu] name - Set target address name addr - Set target transport address IP port - Set target transport address port taglist - Set tag list pname - Set targetParams name del - Delete targetAdd ...

  • NEC N8406-022A - page 74

    Command Line Interface 74 The following table describes the SNMPv3 Target Parameters Table Confi guration Menu options. Table 72 SNMPv3 Target Parameters T able Configuration Menu options Command Description name < 1-32 characters > Configures the locally arbitrary, but unique ident ifier that is associated with this entry. mpmodel snmpv1|snm ...

  • NEC N8406-022A - page 75

    Command Line Interface 75 System Access configuration Command: /cfg/sys/access [System Access Menu] mgmt - Management Network Definition Menu user - User Access Control Menu (passwords) http - Enable/disable HTTP (Web) access https - HTTPS Web Access Menu wport - Set HTTP (Web) server port number snmp - Set SNMP access control tnet - Enable/disable ...

  • NEC N8406-022A - page 76

    Command Line Interface 76 User Access Control configuration Command: /cfg/sys/access/user [User Access Control Menu] uid - User ID Menu eject - Eject user usrpw - Set user password (user) opw - Set operator password (oper) admpw - Set administrator password (admin) cur - Display current user status The following table describes the Us er Access Con ...

  • NEC N8406-022A - page 77

    Command Line Interface 77 HTTPS Access configuration Command: /cfg/sys/access/https [https Menu] access - Enable/Disable HTTPS Web access port - HTTPS WebServer port number generate - Generate self-signed HTTPS server certificate certSave - save HTTPS certificate cur - Display current SSL Web Access configuration The following table describes the H ...

  • NEC N8406-022A - page 78

    Command Line Interface 78 Port configuration Command: /cfg/port < port number > [Port 1 Menu] speed - Set link speed and force full duplex mode fctl - Set flow control auto - Set auto negotiation name - Set port name ena - Enable port dis - Disable port cur - Display current port configuration This menu enables you to con figure settings for ...

  • NEC N8406-022A - page 79

    Command Line Interface 79 Group configuration Command: /cfg/group <1-5> [Group 1 Menu] addport - Add ports to the group remport - Remove ports from the group addvlan - Add non-default (tagged) VLANs to the group remvlan - Remove non-default (tagged) VLANs from the group pvid - Set default port VLAN id for the group igmp - Enable/Disable IGMP ...

  • NEC N8406-022A - page 80

    Command Line Interface 80 Configuration Dump Command: /cfg/dump The dump program writes the current s witch configuration to the terminal screen. T o start the dump program, at the Configuration# prompt, enter: Configuration# dump The configuration is displaye d with parameters that have been changed from the default v alues. The screen displa y ca ...

  • NEC N8406-022A - page 81

    Command Line Interface 81 Operations Menu Introduction Operations-level commands are used for ma king imme diate and tempor ar y changes to sw itch configuration. The Operations Menu is used for bringing ports temporar il y in and out of service. This menu is available only from an administrator and operator login. Menu information Command: /oper [ ...

  • NEC N8406-022A - page 82

    Command Line Interface 82 Boot Options Menu Introduction You must be logged in to the switch as the administrator to use the Boot Options Me nu. The Boot Options Menu provides opti ons for: • Selecting a switch software image to be used when the switch is next reset . • Selecting a configuration bloc k to be used when the switch is next reset. ...

  • NEC N8406-022A - page 83

    Command Line Interface 83 The exact form of the name will vary by FTP/TFT P server. However, the file location is normally relative to the FTP/TFTP director y. 5. Enter the username, if y ou are using a F TP server: Enter username for FTP server or hit return for TFTP server: < userID > 6. Enter the password for the FTP server (if prompted): ...

  • NEC N8406-022A - page 84

    Command Line Interface 84 Uploading a software image from the switch You can upload a software image from the switch to a F T P or TFTP server. 1. At the Boot Options# prompt, enter: Boot Options# ptimg 2. The system prompts you for info rmation. Enter the desired image: Enter name of switch software image to be uploaded ["image1"|"i ...

  • NEC N8406-022A - page 85

    Command Line Interface 85 Resetting the switch You can reset the switch to make your soft ware image file and configuration block chang es occur. Resetting the switch causes the Spanning T r ee Protoco l to restart. This process can be lengthy, depending on the topology of your net work. To reset the switch, at the Boot Options# prompt, enter: > ...

  • NEC N8406-022A - page 86

    Command Line Interface 86 Maintenance Menu Introduction The Maintenance Menu is use d for debu gging purposes, en abling yo u to generate a technical su pp ort dump of the critical state information in the switch, and to clear entr ies in the Forwarding Databas e and the Address Resolution Protocol (ARP). This menu is available on ly from an admini ...

  • NEC N8406-022A - page 87

    Command Line Interface 87 Forwarding Manipulation options Command: /maint/fdb [FDB Manipulation Menu] find - Show a single FDB entry by MAC address port - Show FDB entries for a single port vlan - Show FDB entries for a single VLAN dump - Show all FDB entries add - Add a FDB entry del - Delete a FDB entry clear - Clear entire FDB, then re-add stati ...

  • NEC N8406-022A - page 88

    Command Line Interface 88 ARP cache options Command: /maint/arp [Address Resolution Protocol Menu] find - Show a single ARP entry by IP address port - Show ARP entries on a single port vlan - Show ARP entries on a single VLAN addr - Show ARP entries for switch's interfaces dump - Show all ARP entries clear - Clear ARP cache The following table ...

  • NEC N8406-022A - page 89

    Command Line Interface 89 IGMP Multicast Routers options Command: /maint/igmp/mrouter [IGMP Multicast Routers Menu] vlan - Show all multicast router ports on a single vlan dump - Show all multicast router ports clear - Clear multicast router port table The following table describes the IGMP Mu lticast Routers M aintenance Menu options. Table 92 IGM ...

  • NEC N8406-022A - page 90

    Command Line Interface 90 FTP/TFTP system dump put Command: /maint/ptdmp < server > < filename > Use this command to put (save) the sy stem dump to a FTP or TFT P server. NOTE: If the FT P or TFT P server is running SunOS or the Solaris operati ng sy stem, the specified ptdmp file must exist prior to executing the ptdmp comm and, and mu ...

Manufacturer NEC Category Switch

Documents that we receive from a manufacturer of a NEC N8406-022A can be divided into several groups. They are, among others:
- NEC technical drawings
- N8406-022A manuals
- NEC product data sheets
- information booklets
- or energy labels NEC N8406-022A
All of them are important, but the most important information from the point of view of use of the device are in the user manual NEC N8406-022A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals NEC N8406-022A, service manual, brief instructions and user manuals NEC N8406-022A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product NEC N8406-022A.

Similar manuals

A complete manual for the device NEC N8406-022A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use NEC N8406-022A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of NEC N8406-022A.

A complete NEC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual NEC N8406-022A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the NEC N8406-022A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the NEC N8406-022A, that we can find in the current document
3. Tips how to use the basic functions of the device NEC N8406-022A - which should help us in our first steps of using NEC N8406-022A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with NEC N8406-022A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of NEC N8406-022A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning NEC N8406-022A?

Use the form below

If you did not solve your problem by using a manual NEC N8406-022A, ask a question using the form below. If a user had a similar problem with NEC N8406-022A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)