    T ABLE OF CONTENTS INTRODUCTION 1 IMPORT ANT SAFEGUARDS 1 P ACKAGE CONT AINS: 1 NAMES OF P ARTS 2 INST ALLA TION BEFORE USE 3 CONTROL P ANEL AND LCD DISPLA Y 5 CONTROL PANEL FUNCTIONS 6 OPERA TION USING CONTROL P ANEL 7 OPERA TION USING REMOTE CONTROLLER 8 CONDENSA TE W A TER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL SPECIFICA TIONS 1 ...

  • Soleus Air KY-320 - page 3

    1 INTRODUCTION Thank you for purchasing the Soleus Air KY32U portable air-conditioner . This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. W ith its whisper quite operation and attractive design, you will enjoy the convenience and comfort th ...

  • Soleus Air KY-320 - page 4

    2 NAMES OF P ARTS Front V iew Back V iew control panel upper air outlet handle lower air inlet grille Signal Receptor upper air inlet grill with filter power cord hot air exhaust outlet lower air inlet grille water tank continuous drainage Exhaust Duct T erminal ...

  • Soleus Air KY-320 - page 5

    3 Exhaust Duct W indow Kits INST ALLA TION BEFORE USE 1) Condensate W ater T ank Float Lid Y ou must install the water tank float lid before first use of the portable air conditioner following these procedures: a) Hold the water tank and draw it out slowly . b) Remove water tank float lid and packing material from the water tank. c) Insert the floa ...

  • Soleus Air KY-320 - page 6

    4 water tank float lid should be able to move up and down freely after correct installment. d) Insert the complete water tank back to the air conditioner unit. 2) Exhaust Duct When you use the unit as an air conditioner , the hot exhaust air must be directed out of the room. The exhaust duct is used to allow the hot air out. DO NOT INST ALL OR USE ...

  • Soleus Air KY-320 - page 7

    5 f ) Use screws on the window kit extension if necessary . NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements should be taken. CONTROL P ANEL AND LCD DISPLA Y CONTROL P ANEL LCD DISPLA Y ...

  • Soleus Air KY-320 - page 8

    6 Control Panel Functions 1) Power On/Off Control Starts or Stops the Unit 2) Mode Control Select the functions of the unit for: Fan only Air Conditioning onlyDehumidifying only Auto Control 3) Fan Speed Control Select the fan speed for: High Medium Slow 4) T emperature Setting Control Select the desired temperature setting by pressing either / or ...

  • Soleus Air KY-320 - page 9

    7 OPERA TION USING CONTROL P ANEL 1) Cooling Operation a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly . c) Plug the Power Cord to the power outlet. d) T urn on the unit by pressing the On/Off Button on the control panel. For Manual Mode: Press the Mode Button until the snowflakes and  Cool  ...

  • Soleus Air KY-320 - page 10

    8 NOTE: Do not use the exhaust duct when the unit is running at dehumidifying model. Y ou must remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the fan speed cannot be adjusted. Keep the windows and the doors closed to aid the effectiveness of the unit in removing the moisture from the room. 3) Fan Operation a) ...

  • Soleus Air KY-320 - page 11

    9 REMOTE CONTROLLER 1) Set Clock a) Press On/Off key to turn on the remote controller b) Press left side (Hour) or right side (Minute) of the T ime Adjustment key until the LCD displays the correct time. c) Press the T ransmit key to set time. 2) Cooling Operation a) Press the On/Off key to turn on the remote controller b) Press the Mode key until ...

  • Soleus Air KY-320 - page 12

    10 d) Press the Fan Speed key until the LCD displays the desired fan speed. e) Press the T ransmit key . NOTE: When pressing the Mode Key , the LCD displays “COOL”, “F AN” AND “HEA T”. This KY-32U unit does not have a heating function. 3) Dehumidifying Operation a) Press the On/Off key to turn on the remote controller b) Press Dehumidif ...

  • Soleus Air KY-320 - page 13

    11 7) Sleep Mode a) Press the On/Off key to turn on the remote controller . b) Press the Sleep key . “Sleep” will appear on the LCD display . c ) Press either / of / key of the T emperature key until the LCD displays the desired temperature. d) Press the Fan Speed key until the LCD displays the desired fan speed. e) Press T imer and T ime Adj ...

  • Soleus Air KY-320 - page 14

    12 mode, condensate water does not go to the internal water tank. Condensate is discharged by gravity through the drainage tubing to either an external tank (not provided) or to a condensate water pump device (Optional Item). When the unit is operating on continuous drainage mode, it can operate con- tinuously without periodic stops to empty the wa ...

  • Soleus Air KY-320 - page 15

    13 maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. a) Push down the two tabs on the filter cover and pull outwards to remove the entire filter and cover . b) Carefully , take the air filter out ...

  • Soleus Air KY-320 - page 16

    14 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate Unit is unplugged Securely plug receptacle into the power outlet Drain tank is full Empty water tank W ater tank not installed correctly Completely insert water tank Air exhaust is clogged Clear exhaust hose T imer is on Cancel the timer and wait for it to run automatically Ther ...

  • Soleus Air KY-320 - page 17

    15 TECHNICAL SPECIFICA TIONS NOTE: 1 ) The above cooling capacity is measured at ambient temperature of DB 86 F , WB 78 F . 2 ) Noise level is measured at the point where is 3.28 ft away from the front of the unit, in cooling mode. 3 ) Power consumption is measured when fan runs at the highest speed Specifications above are for reference only . Ple ...

  • Soleus Air KY-320 - page 18

    16 ELECTRIC PRINCIPLE DRA WING KY-32U ...

  • Soleus Air KY-320 - page 19

    17 W ARRANTY ONE YEAR LIMITED W ARRANTY Soleus International Inc. warrants the accompanying Soleus Air KY-32U Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If t ...

  • Soleus Air KY-320 - page 20

    18 LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and ...

Manufacturer Soleus Air Category Air Conditioner

Documents that we receive from a manufacturer of a Soleus Air KY-320 can be divided into several groups. They are, among others:
- Soleus Air technical drawings
- KY-320 manuals
- Soleus Air product data sheets
- information booklets
- or energy labels Soleus Air KY-320
All of them are important, but the most important information from the point of view of use of the device are in the user manual Soleus Air KY-320.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Soleus Air KY-320, service manual, brief instructions and user manuals Soleus Air KY-320. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Soleus Air KY-320.

A complete manual for the device Soleus Air KY-320, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Soleus Air KY-320 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Soleus Air KY-320.

A complete Soleus Air manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Soleus Air KY-320 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Soleus Air KY-320, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Soleus Air KY-320, that we can find in the current document
3. Tips how to use the basic functions of the device Soleus Air KY-320 - which should help us in our first steps of using Soleus Air KY-320
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Soleus Air KY-320
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Soleus Air KY-320 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Soleus Air KY-320?

Use the form below

If you did not solve your problem by using a manual Soleus Air KY-320, ask a question using the form below. If a user had a similar problem with Soleus Air KY-320 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)