Reliance Water Heaters D85500PE - page 1
COMMERCIAL GAS W A TER HEA TERS Instruction Manual PRINTED 021 1 318300-001 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE. ? ...
-
Reliance Water Heaters D85500PE - page 2
2 ? ...
-
Reliance Water Heaters D85500PE - page 3
3 SAFE INST ALLA TION, USE AND SERVICE ? ...
-
Reliance Water Heaters D85500PE - page 4
4 GENERAL SAFETY INFORMA TION Fire Hazard Do not install water heater on carpeted floo r. Do not operate water heater if flood damaged. For continued protection against risk of fire: Fire or Explosion Hazard Read instruction manual before installing, using or servicing water heater . Av oid all ignition sources if you smell gas. Do not store or use ...
-
Reliance Water Heaters D85500PE - page 5
5 PRECAUTIONS ? ...
-
Reliance Water Heaters D85500PE - page 6
6 ? ...
-
Reliance Water Heaters D85500PE - page 7
THE HYDRO CANNON (SELF-CLEANING SYSTEM) ? ...
-
Reliance Water Heaters D85500PE - page 8
8 TOP VIEW F TOP OUTLET 1 1/2” NPT TOP INLET 1 1/2” NPT FIGURE 5 ROUGH IN DIMENSIONS RECOVER Y CAP ACITIES GAS AND ELECTRICAL CHARACTERISTICS FRONT VIEW BACK VIEW T ABLE 2. RECOVERY CAP ACITIES, based on 80% efciency T ABLE 3. GAS AND ELECTRICAL CHARACTERISTICS T ABLE 1. ROUGH-IN-DIMENSIONS Input Rate Btu/Hr A ...
-
Reliance Water Heaters D85500PE - page 9
9 FLAMMABLE ITEMS, ? ...
-
Reliance Water Heaters D85500PE - page 10
10 INSULA TION BLANKET Do not obstruct water heater air intake with insulating blanket. Gas and carbon monoxide detectors are available. Install water heater in accordance with the instruction manual. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Breathing Hazard - Carbon Monoxide Gas ? ...
-
Reliance Water Heaters D85500PE - page 11
11 Breathing Hazard - Carbon Monoxide Gas Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Under no circumstances should the input exceed the rate shown on the water heater ’s rating label. Overfiring could result in damage to the water heater and sooting. Gas and carbon monoxide detectors ...
-
Reliance Water Heaters D85500PE - page 12
12 W A TER TEMPERA TURE CONTROL AND MIXING V AL VES Wa ter temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury . Feel water before bathing or showering. Te mperature limiting devices such as mixing val ...
-
Reliance Water Heaters D85500PE - page 13
13 HO T WA TER OUTLET TO TA NK INLET CHECK VA LV E MIXING VA LV E COLD WA TER INLET TEMPERED WA TER OUTLET 12” TO 15” (30-38 cm) CHECK VA LV E FIGURE 10 DISHW ASHING MACHINES ...
-
Reliance Water Heaters D85500PE - page 14
14 ...
-
Reliance Water Heaters D85500PE - page 15
15 ? ...
-
Reliance Water Heaters D85500PE - page 16
16 ? ...
-
Reliance Water Heaters D85500PE - page 17
? ...
-
Reliance Water Heaters D85500PE - page 18
18 TYPE B GAS VENT Multiple Gas Fired T ank-T ype Heaters ? ...
-
Reliance Water Heaters D85500PE - page 19
19 W A TER HEA TER INST ALLA TION ? ...
-
Reliance Water Heaters D85500PE - page 20
20 INST ALLA TION DIAGRAMS - TOP INLET/OUTLET USAGE ? ...
-
Reliance Water Heaters D85500PE - page 21
21 HEA TER WIRING ? ...
-
Reliance Water Heaters D85500PE - page 22
22 GAS PIPING ...
-
Reliance Water Heaters D85500PE - page 23
23 ? ...
-
Reliance Water Heaters D85500PE - page 24
24 LIGHTING & OPERA TION LABEL FLAMMABLE If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury , or loss of life. W ARNING OPERA TING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERA TING A. 1. 6. 2. C. D. B. This appliance does not have a pilot. It is equipped with an ignition d ...
-
Reliance Water Heaters D85500PE - page 25
25 CHECK VENTING ? ...
-
Reliance Water Heaters D85500PE - page 26
26 ...
-
Reliance Water Heaters D85500PE - page 27
DRAINING AND FLUSHING Burn harzard. Hot water discharge. Keep hands clear of drain valve discharge. ...
-
Reliance Water Heaters D85500PE - page 28
28 ? ...
-
Reliance Water Heaters D85500PE - page 29
29 ? ...
-
Reliance Water Heaters D85500PE - page 30
30 SYSTEM DIAGNOSTICS ? ...
-
Reliance Water Heaters D85500PE - page 31
31 ? ...
-
Reliance Water Heaters D85500PE - page 32
32 SEQUENCE OF OPERA TION FLOW CHART FIGURE 29 ...
-
Reliance Water Heaters D85500PE - page 33
33 OPERA TIONAL CHECKLIST COMPLAINT CAUSE REMEDY USER SERVICE AGENT *W ater not hot enough temperature ? ...
-
Reliance Water Heaters D85500PE - page 34
34 W A TER PIPING DIAGRAMS N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi ce v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t r ...
-
Reliance Water Heaters D85500PE - page 35
35 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 36
36 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 37
N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired ...
-
Reliance Water Heaters D85500PE - page 38
38 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 39
39 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 40
40 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 41
41 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FLUE (2 UNITS) TWO TEMPERA TURE LEGEND TEMPERA TURE ...
-
Reliance Water Heaters D85500PE - page 42
42 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE (2 UNITS) WITH BOOSTER TWO TEMPERA TURE LEGEND ...
-
Reliance Water Heaters D85500PE - page 43
43 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI-FL UE (3 UNITS) LEGEND TEMPERA TURE & PRESSURE R ...
-
Reliance Water Heaters D85500PE - page 44
44 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 45
45 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 46
46 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE FLUE (4 UNITS) LEGEND TEMPERA TURE & PRESS ...
-
Reliance Water Heaters D85500PE - page 47
N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired ...
-
Reliance Water Heaters D85500PE - page 48
48 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
Reliance Water Heaters D85500PE - page 49
49 MANIFOLD KITS MANIFOLD KITS TWO UNIT MANIFOLD KIT (P ART NO. 9003426205) THREE UNIT MANIFOLD KIT (P ART NO. 9003427205) FOUR UNIT MANIFOLD KIT (P ART NO. 9003428205) DIMENSION "A" MODEL 81.5" D85500NE/D85500PE ...
-
Reliance Water Heaters D85500PE - page 50
50 LIMITED W ARRANTY Limited W arranty Reliance Water Heater Company, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the THREE y ...
-
Reliance Water Heaters D85500PE - page 51
NOTES ...
-
Reliance Water Heaters D85500PE - page 52
? ...
Do you have a question concerning Reliance Water Heaters D85500PE?
Use the form below
If you did not solve your problem by using a manual Reliance Water Heaters D85500PE, ask a question using the form below. If a user had a similar problem with Reliance Water Heaters D85500PE it is likely that he will want to share the way to solve it.