Manual Bunn TB6Q

27 pages 4 mb
Download

Go to site of 27

Summary
  • Bunn TB6Q - page 1

    SER VICE & REP AIR MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 41722.0000A 07/09 ©2009 Bunn-O-Matic Corporation TB3/TB6 Series Including: TB3; TB3-LP; TB3Q; TB3Q-LP; TB6; TB6Q ST ARTING WITH SERIAL NUMBER: TU00020000 ...

  • Bunn TB6Q - page 2

    Page 2 41722 012609 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years ...

  • Bunn TB6Q - page 3

    Page 3 41722 070209 Contents T rouble Shooting .............................................................................................................. 4 Component Acess ......................................................................................................... 10 Control Thermostat .............................................. ...

  • Bunn TB6Q - page 4

    Page 4 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department. • Inspection, testing, and repair of electrical equipment s ...

  • Bunn TB6Q - page 5

    Page 5 TROUBLESHOOTING (cont.) Brew cycle will not start (cont.) Water is not hot PROBABLE CAUSE REMEDY 3. ON/OFF Switch 4. Start Switch 5. Timer 6. Solenoid Valve 7. Water strainer/flow control (If equipped) 1. (A) Limit Thermostat (B) Thermal Cut-Off (230V) CAUTION - Do not eliminate or bypass limit thermostat or thermal cut-off. Use only BOM re ...

  • Bunn TB6Q - page 6

    Page 6 TROUBLESHOOTING (cont.) Inconsistent beverage level in dispenser Consistently low beverage level in the dispenser Spitting or excessive steaming 1. Strainer /flow control (If equipped) 2. Syphon System 3. Lime Build-up CAUTION - T ank and tank com- ponents should be delimed regularly depending on local water conditions. Excessive min- eral ...

  • Bunn TB6Q - page 7

    Page 7 TROUBLESHOOTING (cont.) Spitting or excessive steaming (cont.) Dripping from sprayhead Water flows into tank continu- ously (ON/OFF Switch "ON") Water flows into tank continu- ously (ON/OFF Switch "OFF") Beverage overflows dispenser 2. Control Thermostat 1. Syphon System 2. Lime Build-up CAUTION - T ank and tank com- p ...

  • Bunn TB6Q - page 8

    Page 8 TROUBLESHOOTING (cont.) Weak beverage Dry coffee grounds remain in the funnel Brewer is making unusal noises 1. Filter T ype 2. Coffee Grind 3. Sprayhead 4. Funnel Loading 5. Water T emperature 1. Funnel Loading 1. Solenoid 2. Plumbing Lines 3. Water Supply PROBLEM PROBABLE CAUSE BUN N® pa per filte rs must be used for proper extraction. A ...

  • Bunn TB6Q - page 9

    Page 9 TROUBLESHOOTING (cont.) Brewer is making unusal noises (cont.) 4. T ank Heater Remove and clean lime off the tank heater . PROBLEM PROBABLE CAUSE REMEDY 41722 070209 ...

  • Bunn TB6Q - page 10

    Page 10 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified servic ...

  • Bunn TB6Q - page 11

    Page 11 SERVICE (cont.) source. The indication must be: a) 120 volts ac for two wire 120 volt models. b) 200 to 230 volts ac for two wire 200 volt or 230 volt models. 8. Disconnect the brewer from the power source. If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermo ...

  • Bunn TB6Q - page 12

    Page 12 SERVICE (cont.) LIMIT THERMOST A T Location: The limit thermostat is located inside the rear of the hood on the tank lid. T est Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue and black wires from the limit thermostat. 3. Check for continuity across the limit thermostat terminals with a ohmmeter . FIG. 12- ...

  • Bunn TB6Q - page 13

    Page 13 SERVICE (cont.) T ANK HEA TER Location: The tank heater is located inside the tank and secured to the tank lid. T est Procedures: 1. Disconnect the brewer from the power supply . 2. T urn on thermostat. Check the voltage across the black and white wires on 120 volt models or the black and red wires for 200 volt models and 230 volt models wi ...

  • Bunn TB6Q - page 14

    Page 14 SERVICE (cont.) LIGHTED ON/OFF SWITCH (TB3/TB3Q) FIG. 14-1 LIGHTED ON/OFF SWITCH P/N 37080.0000 Orange light FIG. 14-2 LIGHTED ON/OFF SWITCH TERMINALS P/N 37080.0000 BLACK 2 WHT/VIO WHITE Location: The ON/OFF switch is located in the front of the hood, above and to the left of the brew funnel. T est Procedure: Brewers W/Out Half Batch or Sw ...

  • Bunn TB6Q - page 15

    Page 15 SERVICE (cont.) ON/OFF SWITCH-TB6/Q (Sweetner ½ Batch Option-TB3/Q) Location: The switch is located on the front control panel. T est Procedure: 1. Disconnect the brewer from the power source. 2. Disconnect the wires from switch terminals. 3. Check for continuity across the center and right and across center and left terminals in rows one ...

  • Bunn TB6Q - page 16

    Page 16 SERVICE (cont.) ST ART SWITCHES Location: The start switch is located in the front of the hood, above and to the right of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power source. 2. Remove the wires from all four terminals. 3. Check for continuity across the two terminals on the right side of the switch when it is h ...

  • Bunn TB6Q - page 17

    Page 17 SERVICE (cont.) INLET V AL VES Location: The solenoid valve(s) are located inside the trunk on the lower center part of the component bracket. So- lenoids in the early models are located in the hood. T est Procedures: 1. Check the solenoid valve for coil action. With "ON/ OFF" switch in the "ON' upper position press star ...

  • Bunn TB6Q - page 18

    Page 18 SERVICE (cont.) BREW/DILUTION TIMER (TB3 & TB6) Location: The timer is located in left side of the hood. T est Procedure: NOTE: Do not remove or instal l wires while timer board is installed. Pressure applied to one side may cause damage to the board . 1. Disconnect the brewer from the power source and remove the top cover . 2. With a v ...

  • Bunn TB6Q - page 19

    Page 19 SERVICE (cont.) BREW/DILUTION TIMER (TB3 & TB6) (cont.) T riacs: TH-1/MV-1 Brew solenoid TH-2/MV-2 Dilution solenoid FIG. 19-1 BREW/DILUTION TIMER TRIACS 41722 070209 ...

  • Bunn TB6Q - page 20

    Page 20 FIG. 20-1 DIGIT AL TIMER FIG. 20-2 DIGIT AL TIMER DIGIT AL BREW TIMER (TB3Q & TB6Q) SERVICE (cont.) Location: The timer is located in left side of the hood. T est Procedure NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board . 1. Disconnect the brewer from the p ...

  • Bunn TB6Q - page 21

    Page 21 SERVICE (cont.) DIGIT AL BREW TIMER (TB3Q & TB6Q) (cont.) T riacs: Q-1/MV-2 Brew solenoid output MV-1 Line in FIG. 21-1 DIGIT AL TIMER TRIACS 41722 070209 ...

  • Bunn TB6Q - page 22

    Page 22 41722 070209 SCHEMA TIC WIRING DIAGRAM TB3Q (OPTIONAL) READY INDICA TOR BLU/BLK BLK SW . & THERMOST A T LIMIT THERMOST A T L1 BLK BLU/BLK BLK GREEN T ANK HEA TER N WHI WHI WHI WHI SW2 "KEEP WARM HEA TER" SW1 BLK WHI/VIO WHI/VIO WHI WHI WHI/ORA WHI/GRN WHI/YEL SOL 1 2 3 4 5 BREW TIMER 37234.0001A 08/04 © 2004 BUNN-O-MA TIC COR ...

  • Bunn TB6Q - page 23

    Page 23 41722 070209 SCHEMA TIC WIRING DIAGRAM TB3, TB3B, TB3-LP OPTIONAL READY INDICA TOR SWITCH & THERMOST A T LIMIT THERMOST A T "KEEP WARM" HEA TER ON/OFF SWITCH 37234.0007A 02/08 © 2008 BUNN-O-MA TIC CORPORA TION ST ART SWITCH DILUTION BREW/DILUTION TIMER BREW T ANK HEA TER BLU/BLK BLK BLK BLK 654321 WHI WHI WHI WHI/VIO WHI/BLU ...

  • Bunn TB6Q - page 24

    Page 24 41722 070209 37234.0008B 10/08 © 2008 BUNN-O-MA TIC CORPORA TION SCHEMA TIC WIRING DIAGRAM TB3B W/HALF-BA TCH 100 V OL TS A C 120 V OL TS A C 2 WIRE + GND SINGLE PHASE OPTIONAL READY INDICA TOR SWITCH & THERMOST A T LIMIT THERMOST A T "KEEP WARM" HEA TER ST ART SWITCH BREW/DILUTION TIMER T ANK HEA TER BLU/BLK BLK BLK 654321 W ...

  • Bunn TB6Q - page 25

    Page 25 41722 070209 LIMIT THERMOST A T BLU/BLK T ANK HEA TER "KEEP WARM" HEA TER ST ART L1 N BLK WHI BLK BREW TIMER WHI WHI GREEN WHI/YEL WHI/ORA BLK WHI/GRN WHI/GRN WHI/VIO WHI BRN/WHI WHI/VIO WHI WHI WHI/BLK SCHEMA TIC WIRING DIAGRAM TB3Q W/SWEETENER & EMPTY BAG DETECT 120 VOL TS AC 2 WIRE SINGLE PHASE THERMOST A T SOL SOL SOL WHI/ ...

  • Bunn TB6Q - page 26

    Page 26 SCHEMATIC WIRING DIAGRAM TB6 WHI/ORN BRN/BLK LEFT/OFF/RIGHT SWITCH SW1B SW1D SW1C SW1A T ANK HEA TER BLK BLU/BLK L1 WHI BLK BLK WHI SW . & THERMOST A T WHI 120 V OL TS A C 2 WIRE SINGLE PHASE "KEEP WARM" HEA TER LIMIT THERMOST A T WHI/VIO WHI/YEL WHI/BLU TIMER 5 6 4 3 2 1 WHI/GRN WHI N WHI 41974.0000A 03/09 © 2009 BUNN-O-MA T ...

  • Bunn TB6Q - page 27

    Page 27 SCHEMATIC WIRING DIAGRAM TB6Q WHI/ORN BRN/BLK LEFT/OFF/RIGHT SWITCH SW1B SW1D SW1C SW1A T ANK HEA TER BLK BLU/BLK L1 WHI BLK BLK WHI SW . & THERMOST A T WHI 120 V OL TS A C 2 WIRE SINGLE PHASE "KEEP WARM" HEA TER LIMIT THERMOST A T WHI/VIO WHI/YEL TIMER 5 4 3 2 1 WHI/GRN WHI N WHI 41975.0000A 03/09 © 2009 BUNN-O-MA TIC CORPOR ...

Manufacturer Bunn Category Coffeemaker

Documents that we receive from a manufacturer of a Bunn TB6Q can be divided into several groups. They are, among others:
- Bunn technical drawings
- TB6Q manuals
- Bunn product data sheets
- information booklets
- or energy labels Bunn TB6Q
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bunn TB6Q.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bunn TB6Q, service manual, brief instructions and user manuals Bunn TB6Q. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bunn TB6Q.

Similar manuals

A complete manual for the device Bunn TB6Q, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bunn TB6Q by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bunn TB6Q.

A complete Bunn manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bunn TB6Q - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bunn TB6Q, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bunn TB6Q, that we can find in the current document
3. Tips how to use the basic functions of the device Bunn TB6Q - which should help us in our first steps of using Bunn TB6Q
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bunn TB6Q
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bunn TB6Q in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bunn TB6Q?

Use the form below

If you did not solve your problem by using a manual Bunn TB6Q, ask a question using the form below. If a user had a similar problem with Bunn TB6Q it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)