  • White Rodgers 50a55-286 - page 1

    GENERAL PRECAUTION ! Application of this type of control may cause flame rollout on initial start-up and could cause personal injury and/or property damage. Replace only with exact model number, includ- ing dash number. Failure to use exact replace- ment control could cause personal injury and/or property damage. If in doubt about whether your wiri ...

  • White Rodgers 50a55-286 - page 2

    2 SPECIFICA TIONS ELECTRICAL RATINGS [@ 77 ° F (25 ° C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive) Flame Current Requirements: Minimum current to insure flame detection: 1 µ a DC* Maximum current for ...

  • White Rodgers 50a55-286 - page 3

    3 MOUNTING AND WIRING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Failure to earth ground the appli- ance or rev ...

  • White Rodgers 50a55-286 - page 4

    4 TR TH MV MV GND FP HLO HLI PS C R G W Y EAC N HUM N XFMR N LINE N CIR N IGN IND IND N IGN N HUM EAC XFMR LINE PARK PARK HEAT COOL IGNITOR Y W G R THERMOSTAT GAS VALVE HIGH LIMIT (N. C.) THERMAL ROLLOUT (N. C.) AUX. HIGH LIMIT (N. C.) PRESSURE SWITCH (N. O.) FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCULAT ...

  • White Rodgers 50a55-286 - page 5

    5 50A55 TERMINAL TERMINAL TYPE SYSTEM COMPONENT CONNECTION TYPICAL SYSTEM WIRING TABLE * maximum recommended flame probe wire length is 36 inches. W G R Y C MV (2 terminals) TR TH RO1 RO2 FP PS HLI HLO GND (unused terminal) IND IGN IND N IGN N COOL HEAT PARK (2 terminals) LINE XFMR EAC (optional) HUM (optional) CIR N LINE N XFMR N EAC N (optional) ...

  • White Rodgers 50a55-286 - page 6

    6 OPERA TION OPTION SWITCHES The option switches on the 50A55-286 control are used to determine the length of the heat delay-to-fan-off periods. The following table shows the time periods that will result from the various switch positions. HEA T MODE In a typical system, a call for heat is initiated by closing the thermostat contacts. This starts t ...

  • White Rodgers 50a55-286 - page 7

    7 DIAGNOSTIC FEATURES The 50A55 control continuously monitors its own opera- tion and the operation of the system. If a failure occurs, the LED will indicate a failure code as shown below. If the failure is internal to the control, the light will stay on continuously. In this case, the entire control should be replaced, as the control is not field- ...

  • White Rodgers 50a55-286 - page 8

    MOUNTING HOLE TEMPLA TE FOR MOUNTING HOLE LOCA TIONS 4.172 ± .007 (2 plcs.) 6.402 ± .010 (2 plcs.) Refer to page 3 of the installation instructions for proper installation. ...

Manufacturer White Rodgers Category Thermostat

Documents that we receive from a manufacturer of a White Rodgers 50a55-286 can be divided into several groups. They are, among others:
- White Rodgers technical drawings
- 50a55-286 manuals
- White Rodgers product data sheets
- information booklets
- or energy labels White Rodgers 50a55-286
All of them are important, but the most important information from the point of view of use of the device are in the user manual White Rodgers 50a55-286.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals White Rodgers 50a55-286, service manual, brief instructions and user manuals White Rodgers 50a55-286. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product White Rodgers 50a55-286.

A complete manual for the device White Rodgers 50a55-286, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use White Rodgers 50a55-286 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of White Rodgers 50a55-286.

A complete White Rodgers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual White Rodgers 50a55-286 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the White Rodgers 50a55-286, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the White Rodgers 50a55-286, that we can find in the current document
3. Tips how to use the basic functions of the device White Rodgers 50a55-286 - which should help us in our first steps of using White Rodgers 50a55-286
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with White Rodgers 50a55-286
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of White Rodgers 50a55-286 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning White Rodgers 50a55-286?

Use the form below

If you did not solve your problem by using a manual White Rodgers 50a55-286, ask a question using the form below. If a user had a similar problem with White Rodgers 50a55-286 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)