Manual Greenheck Fan QEI

52 pages 2.98 mb
Download

Go to site of 52

Summary
  • Greenheck Fan QEI - page 1

    May 2012 Mixed Flow Fans Belt and Direct Drive Models QEI-L, QEI, QEID ...

  • Greenheck Fan QEI - page 2

    Model QEI-L – Belt Drive • 11sizesavailable(12thru36) • VolumeRange: 700-40,000cfm  (1190-67,960m 3 /hr) • StaticPressure:Upto5in.wg(1245Pa) 2 Quiet & Efficient, Inline • Performanceascatalogedisassured.Allsizesare licensed? ...

  • Greenheck Fan QEI - page 3

    3 3 Standard Construction Housing Tubularhousingsareconstructedofweldedsteelto eliminateairleakage.Integralstraighteningvanesare constructedfromsteelandweldedintoplace. Wheel – Mixed Flow Fabricatedwheelsareconstructedfromsteel.The bladeprofilesareangled? ...

  • Greenheck Fan QEI - page 4

    Value Added Features Maintenance / Serviceable Construction Advantages Thefollowingvalueaddedfeaturesareincorporatedintothedesigntoallowforquickand easyfieldservice. QEI-LandQEI serviceadvantages: •  Bearinglubricationisperformedthroughextendedgreasefitti ...

  • Greenheck Fan QEI - page 5

    5 Inlet and Outlet Sound Power Levels AllGreenheckmixedflowfanshaveAMCAlicensedsoundpowerlevelsforboththe faninletandoutlet. Applicationandinstallationdetermineswhichsoundpowerreading(inlet,outlet, orboth)iscritical.Thedifferencesbetweenthegener ...

  • Greenheck Fan QEI - page 6

    6 Design & Performance Mixed Flow: Axial/Centrifugal Hybrid A mixedflow wheel isa hybrid between anaxial propeller anda centrifugal wheel.The result isa design that combinesthe best axial and centrifugalproperties: highly efficientair movement, incre ...

  • Greenheck Fan QEI - page 7

    7 Wheel Characteristics Static Pressure CFM 50% Wheel Width 50% Wheel Width 100% Wheel Width 100% Wheel Width Intermediate Wheel Widths Static Pressur e CFM 50% Wheel Width 50% Wheel Width 100% Wheel Width 100% Wheel Width Intermediate Wheel Widths Static Pressure CFM 50% Wheel Width 50% Wheel Width 100% Wheel Width 100% Wheel Width Intermediate Wh ...

  • Greenheck Fan QEI - page 8

    8 Optional Features TheSure-Aire™flowmonitoringsystemmeasuresfan flowwithina3%accuracy.Unliketraditionalflowprobes mountedinthefanventurithatcreateasystemeffect hinderingfanperformance,Sure-Aire™doesnotinterfere withairflowandwillnot? ...

  • Greenheck Fan QEI - page 9

    9 9 Zinc Advantage Optional Two-coat Paint System In 1972,Greenheck tookthe lead asthe first commercialand industrial fanmanufacturerto introduce electrostaticpowder coatings. T oday ,Greenheck continuesto lead by beingthe first tooffer asuperior zinc-ri ...

  • Greenheck Fan QEI - page 10

    10 Certifications & Listings Seismic Certification The International BuildingCode (IBC) has beenadopted at thestate and local level thr oughout theUnited States. With theadoption of thiscode, comes the introductionof standardsintended to impr ove the ...

  • Greenheck Fan QEI - page 11

    11 Belt Drive versus Direct Drive Example of Annual Operating Cost Savings Forasystemperformancerequirementof25,000cfmat2.5inchesofstaticpressure(wg)thecorresponding operatingpowerrequirementsare13.97BhpwithaQEI-Isize36and19.8Bhpforasize36tubula ...

  • Greenheck Fan QEI - page 12

    12 Belt Drive Mounting Configurations Universal Mounting QEI-I/IImodelssizes9-27andallQEI-Lmodelscanbe mountedhorizontallyorvertically.Foreaseofinstallation, eightmountingbracketsareweldedoneachfan.These eightbracketsalongwithstandardmountingsupports? ...

  • Greenheck Fan QEI - page 13

    13 Roof Upblast & Spark Resistant Construction Roof Upblast ModelsQEI-I/IIsizes9through54andmodelQEID sizes12through54,ar eavailableinroofupblast conguration.Theroofupblastcongurationisideal forexhaustingcontaminantsawayfromabuildingto preve ...

  • Greenheck Fan QEI - page 14

    14 Accessories QEI-L QEI-I QEI-II QEID MotorCover Aweatherproofmotorcovershieldsthemotorcomponents fromdust,dirtandmoistureforindoororoutdoor installations.Motorcoversalsoserveasapersonnelguards andmeetOSHAstandards.  HingedAccessDoor Hingeda ...

  • Greenheck Fan QEI - page 15

    15 Exploded View CompanionFlange OutletFlange (StandardonQEI-L) OutletGuard BoltedAccessDoor (Standard) InletGuard SlipFitConnection (StandardonQEI-I/II) InletFlange (StandardonQEI-L) CompanionFlange SpringBaseIsolator NeopreneBaseIsolator SpringHangingIsolator MotorCover ...

  • Greenheck Fan QEI - page 16

    16 Thequickselectchartsbelowandonthefollowingpageareaconvenientmethodforsizingthefanrequiredfora specificperformance.Coloredbandsforagivensizeineachchartrepresenttheentireoperatingrangeavailable forthatsizeandspeed. ForQE ...

  • Greenheck Fan QEI - page 17

    17 870 RPM (60 Hz) Model QEID 36—54 Volume (cfmx 1000) Static Pressure (in. wg) 10 20 30 40 50 100 8 6 4 2 0 44 40 36 49 54 QEID Dimensional Data Size Slip Fit O.D. Length* Weight** inches mm inches mm lbs. kg. 12 17.13 435 25.0 635 100 45 15 20.88 530 25.0 635 140 65 16 23.00 584 26.0 660 170 80 18 25.38 645 29.0 737 200 95 20 ...

  • Greenheck Fan QEI - page 18

    18 Airflow Height Height Length Length Slip Fit O.D. Airflow QEI Dimensional Data QEI-L QEI Class I QEI Class II Size Slip-Fit O.D. Length Height Slip-Fit O.D. Length Height Length Height inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) 9 NA NA NA 17.13 (435) NA NA 28.5 (724) 36.5 (927) 12 17.5 (445) 26.5 (67 ...

  • Greenheck Fan QEI - page 19

    19 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 20

    20 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 21

    21 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 22

    22 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 23

    23 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 24

    24 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 25

    25 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 26

    26 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 27

    27 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 28

    28 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 29

    29 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 30

    30 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 31

    31 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 32

    32 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 33

    33 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 34

    34 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 35

    35 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 36

    36 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 37

    37 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 38

    38 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 39

    39 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 40

    40 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 41

    41 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 42

    42 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 43

    43 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 44

    44 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 45

    45 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 46

    46 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 47

    47 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 48

    48 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 49

    49 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 50

    50 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 51

    51 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 -12 watts, calculated per AMCA Standard 301. Values shown are for ...

  • Greenheck Fan QEI - page 52

    P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, t ...

Manufacturer Greenheck Fan Category Nail Gun

Documents that we receive from a manufacturer of a Greenheck Fan QEI can be divided into several groups. They are, among others:
- Greenheck Fan technical drawings
- QEI manuals
- Greenheck Fan product data sheets
- information booklets
- or energy labels Greenheck Fan QEI
All of them are important, but the most important information from the point of view of use of the device are in the user manual Greenheck Fan QEI.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Greenheck Fan QEI, service manual, brief instructions and user manuals Greenheck Fan QEI. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Greenheck Fan QEI.

Similar manuals

A complete manual for the device Greenheck Fan QEI, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Greenheck Fan QEI by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Greenheck Fan QEI.

A complete Greenheck Fan manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Greenheck Fan QEI - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Greenheck Fan QEI, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Greenheck Fan QEI, that we can find in the current document
3. Tips how to use the basic functions of the device Greenheck Fan QEI - which should help us in our first steps of using Greenheck Fan QEI
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Greenheck Fan QEI
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Greenheck Fan QEI in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Greenheck Fan QEI?

Use the form below

If you did not solve your problem by using a manual Greenheck Fan QEI, ask a question using the form below. If a user had a similar problem with Greenheck Fan QEI it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)