Manual Superior SLBV-35NE

28 pages 2.9 mb
Download

Go to site of 28

Summary
  • Superior SLBV-35NE - page 1

    SLBV-35NE SLBV-40NE SLBV-35NM SLBV-35PM SLBV-40NM SLBV-40PM ITS Report No. 100017854 Please read and understand these instructions BEFORE starting installation. MODELS I N S T A L L A T I O N I N S T R U C T I O N S B-Vent Gas Fireplaces SLBV 35/40 Models MILLIVOL T : ELECTRONIC: P/N 506009-02 Rev . B 06/2011 This manual is one of a set of two supp ...

  • Superior SLBV-35NE - page 2

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .......................... Page 2 Gas Pressure Requirements ........ ...

  • Superior SLBV-35NE - page 3

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Note: Installation and repair should be done by a qualified ser vice person. The appliance should be inspected before use and at least annually by a professional ser vice person. More frequent cleaning may ...

  • Superior SLBV-35NE - page 4

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Figure 2 - Dexen Electronic Gas Valve Pilot Stage T erminal Pressure-T ap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-T ap (Manifold) Burner Stage T erminal Grou nd (TP) PILOT OUT VENT LO TH TP TH TP ...

  • Superior SLBV-35NE - page 5

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S COLD CLIMA TE INSULA TION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulat ...

  • Superior SLBV-35NE - page 6

    T ermination Heights For V ents Above Flat Or Sloped Roofs Ref. NFP A 54 / ANSI Z223.1 Roof Pitch * F ee t * M e t e r s Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.99 11/12 to 12/12 4.0 1.22 12/12 to 14/12 5.0 1.52 14/12 to 16/12 6.0 1.83 16/12 to 18/12 7.0 2. ...

  • Superior SLBV-35NE - page 7

    5 ( 1 27 ) 8-1/4 ( 2 09 ) 14 ( 3 56 ) 12 ( 3 05 ) 19 ( 48 3) 8 (203) 2 ( 51 ) 4 ( 10 2 ) 6 ( 15 2 ) 8 ( 20 3 ) 10 ( 25 4 ) 12 ( 30 5 ) 10 (254) 14 (356) 18 (457) 16 (406) 12 (305) T op of Appl iance inches (millimeters) Mant el Dep th No te - H ood sh own as po sit ion ed. Figure 6 - Minimum Mantel Clearances Head er Figure 5 - Min imum D istan ce ...

  • Superior SLBV-35NE - page 8

    PRE-INST ALLA TION STEPS (Remove Glass Enclosure Panel) The appliance is shipped with all gas controls and components installed and pre-wired. Note: Remove the glass enclosure panel before installing the fireplace. T o remove the glass enclosure panel: 1. Remove the shipping carton, and then re - move the shipping pad, exposing the front glass pan ...

  • Superior SLBV-35NE - page 9

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S FIREPLACE AND FRAMING SPECIFICA TIONS NO TE: Diag ram s, i llus tra tion s an d ph otog raph s a re n ot t o s cale . Pr odu ct de sign s, m ate rial s, d ime nsio ns, sp ecifi cati ons , co lors , a nd p ...

  • Superior SLBV-35NE - page 10

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S VERTICAL VENTING THROUGH CEILING Frame Ceiling Opening: T o locate the center of the vertical run, use a plumb line from the ceiling above the appliance. Model No. in. mm SLBV-35 32-1/4 819 28-1/8 714 23-1/ ...

  • Superior SLBV-35NE - page 11

    Note: • All appliances are factory-equipped with a ex ible gas line con nector and 1/2 inc h shutof f valve (se e Figure 17 on Page 15 ) . • See Massac husetts Requi rements on Pa ge 4 for additional requirements for installa- tions in the state of Massachusetts in the USA. • The gas supply line should NOT be con- nected to the appliance u ...

  • Superior SLBV-35NE - page 12

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 4. Install Field Wiring CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box. ...

  • Superior SLBV-35NE - page 13

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 MILLIVOL T WIRING DIAGRAM CAU TION : WH EN S ERVI CING CON TROL S, LA BEL ALL WIRE S PR IOR TO D ISCO NNECT ION. WIR ING ERRO RS C AN C AUS ...

  • Superior SLBV-35NE - page 14

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Step 5. [OPTIONAL] Install Outside Combustion Air Kit An option al ou tside combust ion air k it (model FOAK-4, FOAK-4LD, or DK-4) may be used with the se appliances (s ee "Installati on Acces - sories ...

  • Superior SLBV-35NE - page 15

    S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS Figure 17 Step 6. Connect the Gas Line All codes require a shut-off valve mounted in the supply line. The orientation of the shut- off valve should face the front. Figure 16 illustrates two meth ods for conn ...

  • Superior SLBV-35NE - page 16

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S T urn on gas supply and test for gas leaks, us - ing a gas leak test solution (also referred to as bubble leak solution). No te: U si ng a s oa py w ate r s olu ti on i s a n ef fec ti ve l eak tes t so lut ...

  • Superior SLBV-35NE - page 17

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S W ARNING • DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out. • Th ...

  • Superior SLBV-35NE - page 18

    S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS SLBV-35 LOG PLACEMENT INSTRUCTIONS Figure 23 Left Rear Brackets Step 1 Right Rear Bracket Glowing Embers (Do not place Glowing Embers over burner slots.) Step 2 Align hole at the bottom of left front log (1) ...

  • Superior SLBV-35NE - page 19

    SLBV-40 LOG PLACEMENT INSTRUCTIONS Figure 24 Left Rear Log Right Rear Log Ember Chunk Left Front Log Right Front Log 5 4 2 3 1 SLBV Firebox Accessories/Parts Cat. No. M o de l N o . Description H7245 — SLBV-40 Log Set Assembly 88L53 FGE Bag of Glowing Embers (Rockwool) 80L42 FDVS Bag of Decorative Volcanic Stone Note: • Ceramic fiber logs a ...

  • Superior SLBV-35NE - page 20

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées. CAUT ION: DO NOT abus e gla ss enclos ure panel by striking or slamming shu ...

  • Superior SLBV-35NE - page 21

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas S LBV -35 1/ 32 (0.7 94) 1/ 16" (1. 587 ) S LBV -40 1/ 32 (0.7 94) 3/ 16" (4. 763 ) Ad jus tme nt Ro ...

  • Superior SLBV-35NE - page 22

    pull the switch/bracket assembly (with low voltage wires attached) through the side panel slot into the rebox. 8 - Replace the switch, if necessar y .. 9 - Reinstall the scoop and lintel. 10 - Reinstall the glass enclosure panel and control compartment access panel. The appliance should then relight and remain lit. If this does not occur , conta ...

  • Superior SLBV-35NE - page 23

    Step 12. Install Hood NOTE: All models must have a hood installed prior to operating. Refe r to Figure 30 . Instal l hood by sliding it into the slots on the lower edge of the cabinet top . Step 13. Finishing Requirements Wall Details Complete finished interior wall. T o install the appliance facing flush with the nished wall, position framewo ...

  • Superior SLBV-35NE - page 24

    S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 14. Attach Safety-In-Operation Warnings It is the installer’ s responsibility to ensure these warning labels are properly affixed during inst ...

  • Superior SLBV-35NE - page 25

    Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8271 SLBV-40 H7675 Millivolt SIT Systems Natural Gas T o Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8270 SLBV-40 H7673 Electronic DEXEN Systems Propane Gas T o Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8269 SLBV-40 H7671 In Canada ...

  • Superior SLBV-35NE - page 26

    Electronic Appliances Ste p 8. Dexen Electronic V alves: Refer to Figure 34 and the instructions pro- vided with the kit. a. Remove and discard the two pres- sure regulator mounting screws. b. Remove the pressure regulator and diaphragm. c. Discard all removed components. d. Make sure the provided diaphragm is installed properly onto the re- placem ...

  • Superior SLBV-35NE - page 27

    Notes S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ...

  • Superior SLBV-35NE - page 28

    Printed in U.S.A. © 2010 Lennox Hearth Products P/N 506009-02 Rev . B 06/2011 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specications, prices and also to discontinue colors, styles and products. Consult your local distributor for replace code information. S U PE R I O R ® B ...

Manufacturer Superior Category Indoor Fireplace

Documents that we receive from a manufacturer of a Superior SLBV-35NE can be divided into several groups. They are, among others:
- Superior technical drawings
- SLBV-35NE manuals
- Superior product data sheets
- information booklets
- or energy labels Superior SLBV-35NE
All of them are important, but the most important information from the point of view of use of the device are in the user manual Superior SLBV-35NE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Superior SLBV-35NE, service manual, brief instructions and user manuals Superior SLBV-35NE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Superior SLBV-35NE.

Similar manuals

A complete manual for the device Superior SLBV-35NE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Superior SLBV-35NE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Superior SLBV-35NE.

A complete Superior manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Superior SLBV-35NE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Superior SLBV-35NE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Superior SLBV-35NE, that we can find in the current document
3. Tips how to use the basic functions of the device Superior SLBV-35NE - which should help us in our first steps of using Superior SLBV-35NE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Superior SLBV-35NE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Superior SLBV-35NE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Superior SLBV-35NE?

Use the form below

If you did not solve your problem by using a manual Superior SLBV-35NE, ask a question using the form below. If a user had a similar problem with Superior SLBV-35NE it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)