  • TDK Powereta iQP 5V/50A - page 1

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 1/15 Pow ereta ™ iQP Se ries DC/D C Pow er Mo dules 48V Input, 5V / 50 A /250 W Output Quarter Bri ck The Powereta™ Series offers an industry standard Double-P quarter brick high current po ...

  • TDK Powereta iQP 5V/50A - page 2

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 2/15 Ordering infor mation: Product Identifi er Package Size Platfo rm Input Voltage Output Current/ Power Output Units Ma in Output Voltage # of Outputs Safety Class Feature Set i Q P 48 050 A ...

  • TDK Powereta iQP 5V/50A - page 3

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 3/15 Mechanical Sp ecifica tion : Dimensions are in mm [in]. Unless otherwise specified to lerances are: x.x ± 0.5 [0.02], x.xx and x.x xx ± 0.25 [0.010] . Pin A ssignment: PIN FUNCT ION PIN ...

  • TDK Powereta iQP 5V/50A - page 4

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 4/15 A bsolute Maximum Ratings : Stress in excess of Absolute Maximum Ratings may caus e per manent damage to the devic e. Input Characteristics: Unless otherwise s pecified, specifications app ...

  • TDK Powereta iQP 5V/50A - page 5

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 5/15 Electrical D ata: iQP48050A050V-000 thro ugh -0x9: 5V, 50 A , 250W Output Characteri stic Mi n Ty p M ax Unit Notes & Conditions Output Voltage Initial Setpoi nt 4.88 5 5.12 Vdc Vin=Vi ...

  • TDK Powereta iQP 5V/50A - page 6

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Quar ter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 6/15 Electrical C haracte rist ics: iQP48050A050V-000 thro ugh -0x9: 5V, 50 A , 250W Output 70 75 80 85 90 95 0 5 10 15 20 25 30 35 40 45 50 O utput C urr ent (A ) Ef f i ci e n cy ( %) V in = ...

  • TDK Powereta iQP 5V/50A - page 7

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 7/15 Electrical C haracte ristics : iQP48050A050V-000 thro ugh -0x9: 5V, 50 A , 250W Output 0 1 2 3 4 5 6 0 1 0 2 03 0 4 05 06 0 O utput Curr ent (A ) O ut put V ol t age (V ) V in = 36V V in = ...

  • TDK Powereta iQP 5V/50A - page 8

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 8/15 Thermal Performance: iQP48050 A 050V-000 thro ugh -009: 5V, 50 A , 250W Output Maximum output current vs . a mbient t emperature at nominal input volt age for airflow rates natural convect ...

  • TDK Powereta iQP 5V/50A - page 9

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 9/15 Wind Tunnel Test Setup Figure Dimensions are in millimeters and (inches). Thermal Managemen t: An im portant part of the over all system design pr ocess is t herm al managem ent; therm al ...

  • TDK Powereta iQP 5V/50A - page 10

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 10/15 perform ance page f or the po wer module of interest. In all con ditio ns, the p ower module should be operated be low the m axim um operatin g temper ature sho wn on the derati ng curve. ...

  • TDK Powereta iQP 5V/50A - page 11

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 11/15 Operating Informatio n: Over-Curre nt Protection: The power modules have curr ent lim it protection t o protect th e module during o utput overlo ad and shor t circuit co nditions. During ...

  • TDK Powereta iQP 5V/50A - page 12

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 12/15 Vin(-) On/ Off Vin (+) On/Off Circuit for positiv e or negative logic Outpu t Voltage A djustme nt: The out put voltage of the m odule m ay be adjus ted by using an externa l resistor con ...

  • TDK Powereta iQP 5V/50A - page 13

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 13/15 Sense(+) Trim Vout(-) Sense(-) Vout(+) Rup Circuit to in crease out put volt age 100 1000 10000 100000 02 46 8 1 0 % I nc r eas e i n O utput V o l tage,  (%) Tri m R e s i st an ce (k ...

  • TDK Powereta iQP 5V/50A - page 14

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 14/15 nominal input, f ull load, an d Ta = 40 ˚ C us ing the Telc ordia T R-332 issu e 6 calcu lation method. Impr oper handling or cleani ng process es can adver sely af fect the appear ance, ...

  • TDK Powereta iQP 5V/50A - page 15

    Data S heet: Poweret a TM iQP Series –Singl e Outpu t Qua rter Bric k ©2005-2006 T DK Innoveta In c. iQP 5V/50A Datas heet 8/3 /2006 ℡ ( 877 ) 498-0099 15/15 Safety Con siderations: For saf ety agency ap proval of the system in which the D C-DC po wer module is install ed, the po wer module m ust be ins talled i n complia nce with t he creepa ...

Manufacturer TDK Category Network Card

Documents that we receive from a manufacturer of a TDK Powereta iQP 5V/50A can be divided into several groups. They are, among others:
- TDK technical drawings
- Powereta iQP 5V/50A manuals
- TDK product data sheets
- information booklets
- or energy labels TDK Powereta iQP 5V/50A
All of them are important, but the most important information from the point of view of use of the device are in the user manual TDK Powereta iQP 5V/50A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals TDK Powereta iQP 5V/50A, service manual, brief instructions and user manuals TDK Powereta iQP 5V/50A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product TDK Powereta iQP 5V/50A.

A complete manual for the device TDK Powereta iQP 5V/50A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use TDK Powereta iQP 5V/50A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of TDK Powereta iQP 5V/50A.

A complete TDK manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual TDK Powereta iQP 5V/50A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the TDK Powereta iQP 5V/50A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the TDK Powereta iQP 5V/50A, that we can find in the current document
3. Tips how to use the basic functions of the device TDK Powereta iQP 5V/50A - which should help us in our first steps of using TDK Powereta iQP 5V/50A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with TDK Powereta iQP 5V/50A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of TDK Powereta iQP 5V/50A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning TDK Powereta iQP 5V/50A?

Use the form below

If you did not solve your problem by using a manual TDK Powereta iQP 5V/50A, ask a question using the form below. If a user had a similar problem with TDK Powereta iQP 5V/50A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)