Manual Zephyr ZRM-E36AS

19 pages 0.41 mb
Download

Go to site of 19

Summary
  • Zephyr ZRM-E36AS - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: SEP07.0101 © Zephyr Corporation Roma Island ZRM-E36AS ZRM-E42AS ...

  • Zephyr ZRM-E36AS - page 2

    www .zephyronline.com ...

  • Zephyr ZRM-E36AS - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr ZRM-E36AS - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr ZRM-E36AS - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION 7 RUHGXFHULVNRI¿UHDQGWRSURSHUOH[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV attics, crawl spaces or garages. OPERA TION $OZDVOHDYHVDIHWJULOOHV ...

  • Zephyr ZRM-E36AS - page 6

    List of Materials 4 www .zephyronline.com MODEL: ZRM-E36AS, ZRM-E42AS 2 Top Duct Covers 1 Top Support Frame 2 Bottom Duct Covers 1 Bottom Support Frame 2 Thin Trim Pieces 2 Thick Trim Pieces 1 Hood 4 Halogen Light Bulbs (pre-installed) 2 Metal Filters ( 3 - ZRM-E42AS) 3 Wire Nuts 4 ø14 OD / ø6.5 ID W ashers 4 M5 Wing Nuts 4 M6*50 Wood Screws 10 M ...

  • Zephyr ZRM-E36AS - page 7

    5 Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 F t. x ( ) = Ft. 8” Round, straight 1 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow 24 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. wa ...

  • Zephyr ZRM-E36AS - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4 x 10” rectangular GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ HI¿FLHQF  Always use rigid type metal ducts only . Flexible GXFWVFRXOGUHVWULFWDLUÀRZEXSWR Use calculation w ...

  • Zephyr ZRM-E36AS - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . )DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZ? ...

  • Zephyr ZRM-E36AS - page 10

    8 www .zephyronline.com Installation – +RRG6SHFL¿FDWLRQV 3/4” 7 1/8 ” 10 3/4 ” 7 7/8 ” 10 1/8 ” 12 3/8 ” 8 3/4 ” FRONT 36” or 42” 27” 12” 14” 4” T op Support Frame (ceiling bracket) T op of Hood (blower housing) Side of Hood Front of Hood C/L 4 1/2 ” 3” 1 5/8 ” electrical K/O 1 1/8 ” 1/4” ø5 7/8” 11 5/8 ...

  • Zephyr ZRM-E36AS - page 11

    9  $GGDQGVHFXUHZRRGEORFNLQJ minimum 2 x 4 RQWRFHLOLQJMRLVWV 2. Fasten top support frame to desired location on ceiling using 4 2” wood screws with washers. The wider section of the support bracket faces the front of the hood. 3. Determine height requirement and secure bottom support frame to top support f ...

  • Zephyr ZRM-E36AS - page 12

    10 www .zephyronline.com 7 8 10 9 11 Top Duct Covers Top Support Frame Bottom Duct Covers Bottom Support Frame Thin Trim Piece Thick Trim Piece  $VVHPEOHWRSGXFWFRYHUV With louver holes RYHUVXSSRUWIUDPH8VH0VFUHZV 3 on each side WRVHFXUHGXFWFRYHUVWRHDFK ...

  • Zephyr ZRM-E36AS - page 13

    11 Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust IURPFRRNLQJDUHGUDZQDQG¿OWHUHGEDVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSX ...

  • Zephyr ZRM-E36AS - page 14

    12 www .zephyronline.com Blower Off Lights On/Off Blower On/Speed Selection Blower Off Blower On/Speed Selection Lights On/Off The blower will be switched off by pressing: Switch blower on and select speeds 1 - 3 by pressing: Switch lights on and off by pressing: Controls ...

  • Zephyr ZRM-E36AS - page 15

    13 SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser . After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buf ...

  • Zephyr ZRM-E36AS - page 16

    14 www .zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. 5HPRYHEWXUQLQJEXOEFRXQWHUFORFNZLVH1RWH%XOEGRHVQRWXQVFUH ...

  • Zephyr ZRM-E36AS - page 17

    T roubleshooting 15 TROUBLESHOOTING PROCEDURES FOR ROMA Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power connection with the unit is ...

  • Zephyr ZRM-E36AS - page 18

    16 www .zephyronline.com DESCRIPTION P ART# Replacement Parts /LJKW%XOE05*8:HDFK =%6 0HWDO)LOWHUHDFK  Optional Accessories Recirculating Kit, ZRM-E36AS ZRC-0150 Recirculating Kit, ZRM-E42AS ZRC-0151 5HSODFHPHQW&KDUFRDO)LOWHUHDFK? ...

  • Zephyr ZRM-E36AS - page 19

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ZRM-E36AS can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ZRM-E36AS manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ZRM-E36AS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ZRM-E36AS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ZRM-E36AS, service manual, brief instructions and user manuals Zephyr ZRM-E36AS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ZRM-E36AS.

Similar manuals

A complete manual for the device Zephyr ZRM-E36AS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ZRM-E36AS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ZRM-E36AS.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ZRM-E36AS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ZRM-E36AS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ZRM-E36AS, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ZRM-E36AS - which should help us in our first steps of using Zephyr ZRM-E36AS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ZRM-E36AS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ZRM-E36AS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ZRM-E36AS?

Use the form below

If you did not solve your problem by using a manual Zephyr ZRM-E36AS, ask a question using the form below. If a user had a similar problem with Zephyr ZRM-E36AS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)