Manual Essick Air ECR 3301

16 pages 0.82 mb
Download

Go to site of 16

Summary
  • Essick Air ECR 3301 - page 1

    ESSICK AIR PRODUCTS LITTLE ROCK, ARKANSAS 72209 50209-3 O WNERS MANU AL MODEL NO . ECR 3301 ECR 4000 ECR 4500 ECR 5200 ECR 6600 ECR 7200 CA UTION: Read All Instructions Carefully Bef ore Star ting The Installation. ESSICK CONVER TIBLE DO WN/FR ONT OUTLET EV APORA TIVE AIR COOLER ...

  • Essick Air ECR 3301 - page 2

    2 INST ALLA TION T ools and Supplies Y ou Need ......................................... 3 Saf ety Rules ................................................................... 3 Data ................................................................................ 3 Locating Y our Cooler ...................................................... 4 Conv er ...

  • Essick Air ECR 3301 - page 3

    3 T OOLS AND SUPPLIES Y OU WILL NEED • Pliers • Screwdriv ers • Adjustable Wrenches • T ubing Cutter • 5 / 32 He x Ke y Wrench • Electric Dr ill • Drill Bits • Hammer • Duct Caulking • #10 Sheet Metal Screws • Wiring Supplies, as Required by Local Electrical Code •L e v e l • Duct. As Required (a local sheetmetal shop can ...

  • Essick Air ECR 3301 - page 4

    4 LOCA TING Y OUR COOLER This new design Essic k cooler may be installed as a bot- tom or side air outlet cooler . The cooler must be securely f astened to a frame or pad mount. A roof kit is av ailable from Essick. A duct must be attached to the cooler outlet. The duct must be the same size as the cooler outlet. Sudden duct size changes will decre ...

  • Essick Air ECR 3301 - page 5

    5 1. Remove both louv ers and set them where they will not fall. See pg. 11. 2. Remove f our louver clips on side opposite motor . 3. Remov e a reser voir b y pushing the water crossov er tube from the grommet and lifting out the reservoir . 4. Remov e the second reser voir as abov e. 5. Remove the scre w that holds the wir ing box. 6. Remov e 1 / ...

  • Essick Air ECR 3301 - page 6

    6 INST ALLA TION Lift at cabinet cor ners. The cooler may be lifted by putting a bar or strap through the panel hole and lifting by means of the bar or strap . LIFTING COOLER CA UTION: DO NO T LIFT ON THE LOUVERS. REMO VE THE LOUVERS BEFORE LIFTING. DO NO T LIFT ON THE CENTER OF THE CABINET FLANGES. MOUNTING COOLER 1. Prepare duct to fit model used ...

  • Essick Air ECR 3301 - page 7

    7 INST ALLA TION ELECTRICAL CONNECTIONS The wiring must comply with local codes. If you are not f amiliar with the codes or wiring practices, get prof essional help. Use only an Essick ECR-5 or ECR-7 w all mounted switch. This new cooler does not require pre wetting the pads bef ore star ting cooling and does not hav e a pump . Existing switches wi ...

  • Essick Air ECR 3301 - page 8

    8 INST ALLA TION FINAL ASSEMBL Y AND ADJUSTMENT PUT FLO A T V AL VE IN COOLER Put the float valv e through the spout hole and cabinet hole. Tighten the ring nut. Be sure the float mov es straight up and do wn. TURN THE FLO A T UNTIL A NARRO W SIDE IS UP . Snap the Splash Guard Cov er into the W ater Spout as shown. The W a ter Spout and Splash Guar ...

  • Essick Air ECR 3301 - page 9

    9 IMPOR T ANT NO TE: When checking amperage with the ampmeter , all louv ers must be in place in the cooler , otherwise incorrect setting of the drive pulle y will occur . MO T OR PULLEY ADJUSTMENT NO TE: ALL DUCT CONNECTED COOLERS MUST BE ADJUSTED . Long or small air ducts hav e e xcessive air resistance which decreases air output and motor ampera ...

  • Essick Air ECR 3301 - page 10

    10 HO W Y OUR COOLER WORKS Y our cooler evaporates water to cool air . Evaporative air cooling is the same natural cooling that happens when a breeze springs up after a summer shower . Y ou f eel cool because the rain water e vaporates and carries aw ay heat. Y our new cooler has a motor (1) driv en blower (2) which dra ws outside air through pads ...

  • Essick Air ECR 3301 - page 11

    11 CARE OF Y OUR COOLER NEVER WEAR SHOES WITH SLICK SOLES WHEN Y OU W ORK ON A ROOF . Y OU MA Y SLIP WHEN Y OU LEAST EXPECT IT . NEVER DRAIN W A TER ONTO A R OOF . W A TER RESIDUE MA Y CA USE Y OU T O SLIP OR MA Y ST AIN Y OUR ROOF . USE A DRAIN HOSE T O R UN W A TER TO A RAIN GUTTER OR T O THE GROUND . F ALL CARE: Drain the cooler and water line t ...

  • Essick Air ECR 3301 - page 12

    12 Operation of Roto Belt Coolers in “Hardwater” Areas. 1. Clean the cooler frequently . 2. Remov e mineral buildup from water troughs and Roto Belt to prev ent clogging. 3. A water analysis will determine: mineral content, what water treatments can be used, what cleaning agents should be used. 4. A “ bleed-off ” kit (Stock No . 8C190) shou ...

  • Essick Air ECR 3301 - page 13

    13 REPLA CEMENT P ADS MODEL NUMBER P AD NUMBER ECR 3301 EP-30 ECR 4000 EP-40 ECR 4500 EP-40 ECR 5200 EP-50 ECR 6600 EP-60 PUTTING ON NEW P AD (Fig. 20) THE P ADS NEED NO PREWETTING. 1. Put the lower roller in pad. 2. Fit the low er roller into the bottom slots in the frame. 3. Push the top roller through the pad. Fit the roll end ov er the pad moto ...

  • Essick Air ECR 3301 - page 14

    14 ESSICK CONVERTIBLE DO WN/FRONT OUTLET EV APORA TIVE AIR COOLER MODEL NOS. ECR 3301, ECR 4000, ECR 4500, ECR 5200, ECR 6600, ECR 7200 REP AIR P ARTS ...

  • Essick Air ECR 3301 - page 15

    15 ESSICK CONVERTIBLE DO WN/FRONT OUTLET EV APORA TIVE AIR COOLER MODEL NOS. ECR 3301, ECR 4000, ECR 4500, ECR 5200, ECR 6600, ECR 7200 NO TICE: Order by P AR T NUMBER, not by K ey Number . Refer to the bac k cover of this man ual for par ts ordering information. KEY P ART NUMBER NO. ECR 3301 ECR 4000/4500 ECR 5200 ECR 6600/7200 P ART NAME 1 30439 ...

  • Essick Air ECR 3301 - page 16

    ESSICK AIR PRODUCTS 5800 MURR Y • LITTLE ROCK, ARKANSAS 72209 501-562-1094 owners manual MODEL NO . ECR 3301 ECR 4000 ECR 4500 ECR 5200 ECR 6600 ECR 7200 HO W T O ORDER REP AIR P ARTS ESSICK CONVER TIBLE DO WN/FR ONT OUTLET EV APORA TIVE AIR COOLER The model number of y our cooler will be found on a label fastened to the housing. WHEN ORDERING RE ...

Manufacturer Essick Air Category Humidifier

Documents that we receive from a manufacturer of a Essick Air ECR 3301 can be divided into several groups. They are, among others:
- Essick Air technical drawings
- ECR 3301 manuals
- Essick Air product data sheets
- information booklets
- or energy labels Essick Air ECR 3301
All of them are important, but the most important information from the point of view of use of the device are in the user manual Essick Air ECR 3301.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Essick Air ECR 3301, service manual, brief instructions and user manuals Essick Air ECR 3301. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Essick Air ECR 3301.

Similar manuals

A complete manual for the device Essick Air ECR 3301, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Essick Air ECR 3301 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Essick Air ECR 3301.

A complete Essick Air manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Essick Air ECR 3301 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Essick Air ECR 3301, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Essick Air ECR 3301, that we can find in the current document
3. Tips how to use the basic functions of the device Essick Air ECR 3301 - which should help us in our first steps of using Essick Air ECR 3301
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Essick Air ECR 3301
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Essick Air ECR 3301 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Essick Air ECR 3301?

Use the form below

If you did not solve your problem by using a manual Essick Air ECR 3301, ask a question using the form below. If a user had a similar problem with Essick Air ECR 3301 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)