Manual Quadra-Fire 32198A

40 pages 2.09 mb
Download

Go to site of 40

Summary
  • Quadra-Fire 32198A - page 1

    O - T L Tested and Listed by Beaverton Oregon USA OMNI-Test Laboratories, Inc. C P ar t No . 32198A F ebruar y 15, 2002 SA VE THESE INSTR UCTIONS 1445 N. Highwa y Colville, W A 99114 www .aladdinhear th.com Cape Cod W oodsto v e This manual contains instructions f or Installation, Operation & Maintenance Please read this entire manual bef ore y ...

  • Quadra-Fire 32198A - page 2

    Page 2 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R NO TES My new Cape Cod wood sto ve .... SERIAL NUMBER: D A TE PURCHASED: DEALERSHIP: DEALER PHONE #: ADDITIONAL INFORMA TION PER TINENT T O Y OUR INST ALLA TION: A TT ACH SALES RECEIPT & W ARRANTY STUB HERE: This information will be necessary should your stov e ...

  • Quadra-Fire 32198A - page 3

    Page 3 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R WELCOME ______________________ Group Vice President _______________________ Controller _______________________ Manufacturing Engineer Manager _______________________ Order Fulfillment Manager ______________________ Vice President Research & Development ________ ...

  • Quadra-Fire 32198A - page 4

    Page 4 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R T ABLE OF CONTENTS LISTINGS ............................................................5 SERIAL LABEL & LOCA TON ..........................6 DIMENSIONS .....................................................7 CLEARANCES TOP VENT INST ALLA TIONS ................. ...

  • Quadra-Fire 32198A - page 5

    Page 5 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R LISTINGS These installation instructions describe the installation and operation of the Cape Cod woodsto ve. This stove meets the U.S. En vironmental Protection Agency’ s 1990 particulate emission standards. The Cape Cod is listed by OMNI-T est Laborato- ries, In ...

  • Quadra-Fire 32198A - page 6

    Page 6 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R LABEL LOCA TION: B A CK OF ST O VE SAFETY LABEL M IN IM U M C LE A R A N C ES T O C O MB U S TI B LE MA TE R IALS : In Inches & (M ill im et e rs ) N O TE : A ll "A " , "C " and "F " D im ensions are to th e inside diam eter o f th ...

  • Quadra-Fire 32198A - page 7

    Page 7 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R a ccessor y p ar ts DIMENSIONS FR ONT VIEW SIDE VIEW 26-1/2 27" 27-1/2" 8-1/4" 29" 16" 29-3/4" 16-1/4" 22-1/2" 24-1/4" ...

  • Quadra-Fire 32198A - page 8

    Page 8 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CLEARANCES MINIMUM CLEARANCES T O COMBUSTIBLES (In inches and millimeters.) FIGURES 1, 2 & 3 FIGURE 1 FIGURE 2 FIGURE 3 * W ith 52" high x 42" wide wall protection spaced 1" from comb ustible surface. . W ALL PR O TECTOR SPECIFICA TIONS: MUST BE ...

  • Quadra-Fire 32198A - page 9

    Page 9 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R (In inches and millimeters) FIGURE 4 In a Masonry Fireplace OR Through the W all: Six inch (6") diameter listed double wall air insulated connector pipe with listed factory-b uilt Class “A” chimney or a masonry chimney . (Mobile Home must be equipped with ...

  • Quadra-Fire 32198A - page 10

    Page 10 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CLEARANCES FIGURE 5A NO TE: Additional oor protection is required on rear v ent installations. For this type of installation the oor protector must e xtend the length of the ue and 2" to each side of the ue. Floor protection can consist of a U.L. ...

  • Quadra-Fire 32198A - page 11

    Page 11 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R The Cape Cod has sev eral options av ailable for installation and appearance. These options are packaged and sold separately and are listed belo w . It is a good idea to plan your installation on paper , using exact measurements for clearances and oor protectio ...

  • Quadra-Fire 32198A - page 12

    Page 12 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R A masonry chimney or a factory-built chimne y must be the required height abov e the roof and any other nearby obstructions. The chimney must be at least three feet higher than the highest point where it passes through the roof and at least two feet higher than th ...

  • Quadra-Fire 32198A - page 13

    Page 13 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R There are two separate and different parts to a ue system: the chimney connector and the chimney itself. A. Single wall connector or stovepipe. This must be at least 24 gauge mild steel or 26 g auge blue steel. The sections must be attached to the stov e and to ...

  • Quadra-Fire 32198A - page 14

    Page 14 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION MASONR Y CHIMNEY For optimal performance, masonry chimneys used to vent this appliance should be lined with a 6" stainless steel liner . Installations into a clay f l ue without a stainless steel liner may reduce efciency , cause the glass t ...

  • Quadra-Fire 32198A - page 15

    Page 15 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FIGURE 9 FIGURE 8 INST ALLA TION EIGHT INCH SOLID P A CK CHIMNEY WITH MET AL SUPPOR TS AS A THIMBLE FLOOR PROTECTOR THIMBLE, 12" OF BRICK CEILING JOIST COMBUSTIBLE W ALL 1" CLEARANCE AIR TIGHT CLEANOUT DOOR FIRECLA Y FLUE LINER WITH AIR SP ACE SHEA THING ...

  • Quadra-Fire 32198A - page 16

    Page 16 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R First, make the frame for the thimble, ensuring it is no smaller than 14" square, to maintain a 2" air space around the chimney section. Attach the wall spacer to the chimne y side of the frame. Then insert the frame into the opening, toe nailing it to t ...

  • Quadra-Fire 32198A - page 17

    Page 17 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION FIGURE 10 MASONR Y CHIMNEY , CONT . Chimney Flue Liner Fireclay Liner or Equivalent Masonry Chimney Constructed to NFP A 21 1 Wa ll Spacer Wall Band Trim Collar Chimney Connector 1" (25mm) Air Space to Chimney Section Min. Clearance 2" (51 ...

  • Quadra-Fire 32198A - page 18

    Page 18 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O A MASONR Y FIREPLA CE There are se veral kits a vailable to connect the sto ve to a masonry replace. Look for a listed kit. The kit is an adapter which is installed at the location of the replace damper . The existing damper may ...

  • Quadra-Fire 32198A - page 19

    Page 19 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O A MET AL PREF ABRICA TED CHIMNEY When a metal prefabricated chimney is used, the manufacturer’ s installation instructions must be follo wed precisely . It will be necessary to install the ceiling support package or wall pass throug ...

  • Quadra-Fire 32198A - page 20

    Page 20 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O AN INTERIOR MET AL PREF ABRICA TED CHIMNEY IMPOR T ANT ! FOLLO W THE MANUF A CTURERS’ INST ALLA TION INSTR UCTIONS AND MAINT AIN CLEARANCES AS SPECIFIED ON P A GES 8, 9 & 10. FIGURE 13 FIGURE 14 * REFER TO CLEARANCES TO COMBUSTI ...

  • Quadra-Fire 32198A - page 21

    Page 21 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FIGURE 15 INST ALLA TION CONNECTION T O AN EXTERIOR MET AL PREF ABRICA TED CHIMNEY FIGURE 16 Floor Protector Chimney Combustible Ceiling Combustible W all Insulated "T" Flashing Listed Cap Maintain 2" (51mm) Clearance Through Eave * * * Listed Chimn ...

  • Quadra-Fire 32198A - page 22

    Page 22 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION MOBILE HOME INST ALLA TION W ARNING: NEVER DRA W COMBUSTION AIR FROM A W ALL, FLOOR OR CEILING CA VITY OR FROM ANY ENCLOSED SP A CE SUCH AS AN A TTIC OR GARA GE. CA UTION: THE STRUCTURAL INTEG- RITY OF THE MOBILE HOME FLOOR, W ALL, AND CEILING/ROOF ...

  • Quadra-Fire 32198A - page 23

    Page 23 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION ASSEMBL Y 1 Place the unit in a location near the nal installation area and follo w the procedures below: 2 Open the stove and remov e all the parts and articles packed inside. Inspect all the parts and cast iron body for shipping damage. Contact ...

  • Quadra-Fire 32198A - page 24

    Page 24 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION OUTSIDE AIR KIT INST ALLA TION 1. R e m o ve a l l m a t e r i a l s f r o m p a c k i n g bo x. 2. Mount the e x ange (with pipe tting e xtending out), ov er the intake air opening at the rear of stov e using the f our mounting screws supp ...

  • Quadra-Fire 32198A - page 25

    Page 25 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION BLO WER INST ALLA TION & OPERA TION ADJUSTING THE BLO WER SPEED CONTR OL, IF NECESSAR Y* NO TE : When the speed control is tur ned cloc kwise, it will click on to high speed. T urn the speed control clockwise to decrease the speed. At full clock ...

  • Quadra-Fire 32198A - page 26

    Page 26 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION PRE-USE CHECK Use the following checklist as a guide to ensure a correct and complete installation: All safety warnings hav e been read and fol- lo wed. Floor protection requirements hav e been met. Chimney connector is properly installed. The proper cl ...

  • Quadra-Fire 32198A - page 27

    Page 27 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION W OOD SELECTION AND ST ORA GE W ARNING ! DO NO T LEA VE THE FIRE UN A T - TENDED WHEN THE DOOR IS UNLA TCHED OR WHEN USING FIRESCREEN. CARELESSL Y PLA CED FIREWOOD COULD F ALL OUT OF THE FIREBO X CREA TING A FIRE HAZARD T O Y OUR HOME. W ARNING AL W A Y ...

  • Quadra-Fire 32198A - page 28

    Page 28 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OP A CITY : This helps to determine ho w cleanly your stove is burning. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney , and 0% opacity means that no smoke column can be seen. As you become fam ...

  • Quadra-Fire 32198A - page 29

    Page 29 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION OPERA TING TIPS H er e a r e a f ew t ip s o n o p er a ti n g y ou r C a pe Co d s t ove t o o b ta i n m ax i mu m e ffic ie ncy w it h l owe s t emissions: 1. When initially loading the stove, burn your Cape Cod with the primary air control wide open ...

  • Quadra-Fire 32198A - page 30

    Page 30 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION BUILDING A FIRE B e f o r e l i g h t i n g y o u r fir s t fi re i n t h e s t ov e , make certain that the kaowool blanket is correctly pos ition ed (see page 33 for kao wo ol blank et posit ion), remov e any labels from the glass and ensure that the ...

  • Quadra-Fire 32198A - page 31

    Page 31 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R ASH REMO V AL The Cape Cod is equipped with an ash remov al system. W e recommend emptying the ash pan at least once a week when the stov e is in constant operation. The amount of ash is dependent on the type of w ood being b urned. DO NO T ALLOW ASHES TO BUILD UP ...

  • Quadra-Fire 32198A - page 32

    Page 32 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CHIMNEY CLEANING 1. Remov e all ash from the rebox and extinguish all hot embers before disposal. Allow the stov e to cool completely . 2. Remov e the hotplate as follows: a. Use a 7/16 inch socket to loosen the 3 bolts on the underside of the griddle and turn ...

  • Quadra-Fire 32198A - page 33

    Page 33 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R MAINTENANCE CHIMNEY CLEANING, CONT . V iew of bafes after remo val of griddle and kao wool. CA UTION! T h e ba ffl e a n d k ao w oo l b l a n ke t p l a c em e n t i s crucial to the optimum perf ormance of the Cape Cod. Follo w these steps carefull y to ensur ...

  • Quadra-Fire 32198A - page 34

    Page 34 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R NO TE: Remove all labels from glass prior to lighting the rst re. GLASS CARE & REPLA CEMENT 1. Ensure that the re is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or cardboard. 3. Remov e door with broken g ...

  • Quadra-Fire 32198A - page 35

    Page 35 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R KA O WOOL INSULA TING BAFFLE BLANKET 832-3390 DOOR & GASKET Periodically check the door g asket for proper seal. As the gasket compresses or “seats” during use, it may become necessary to adjust or tighten the door latch either by removing spacer washers, ...

  • Quadra-Fire 32198A - page 36

    Page 36 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R TR OUBLE- SHOO TING DRAFT PROBLEMS The Cape Cod woodstov e requires a minimum ue draft of .10 inches of water column on High, and .04 inches of w ater column on Lo w , as measured with a draft meter . Most woodstove dealers hav e draft meters a vailable to meas ...

  • Quadra-Fire 32198A - page 37

    Page 37 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FLUE DRAFT A proper amount of f lu e draft is required to assure the safe and efcient operation of the Cape Cod woodstov e. Flue draft is measured as negati ve pressure in the chimney . The amount of negati v e pressure determines the strength of the draft. Thi ...

  • Quadra-Fire 32198A - page 38

    Page 38 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R P AR T NO. DESCRIPTION 20637B Door Gasketing only 32084 Door Cam latch only 834-3850 Complete Door Handle Assembly (includes: cam latch, gasketing; porcelain black handle; screw adapter and gold door handle). Current Door Style Replacement 844-9640 Door Frame, Lef ...

  • Quadra-Fire 32198A - page 39

    Page 39 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R W ARRANTY LIMITED LIFETIME WARRANTY The Aladdin Hearth Products limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Aladdin Hearth Products will repair or replace them. These items include but a ...

  • Quadra-Fire 32198A - page 40

    32198A F ebruary 15, 2002 Cape Cod W oodstove A TTENTION INST ALLER: PLEASE RETURN THESE INSTR UCTIONS T O THE ST O VE O WNER WHEN INST ALLA TION IS COMPLETED. R ...

Manufacturer Quadra-Fire Category Stove

Documents that we receive from a manufacturer of a Quadra-Fire 32198A can be divided into several groups. They are, among others:
- Quadra-Fire technical drawings
- 32198A manuals
- Quadra-Fire product data sheets
- information booklets
- or energy labels Quadra-Fire 32198A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Quadra-Fire 32198A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Quadra-Fire 32198A, service manual, brief instructions and user manuals Quadra-Fire 32198A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Quadra-Fire 32198A.

A complete manual for the device Quadra-Fire 32198A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Quadra-Fire 32198A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Quadra-Fire 32198A.

A complete Quadra-Fire manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Quadra-Fire 32198A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Quadra-Fire 32198A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Quadra-Fire 32198A, that we can find in the current document
3. Tips how to use the basic functions of the device Quadra-Fire 32198A - which should help us in our first steps of using Quadra-Fire 32198A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Quadra-Fire 32198A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Quadra-Fire 32198A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Quadra-Fire 32198A?

Use the form below

If you did not solve your problem by using a manual Quadra-Fire 32198A, ask a question using the form below. If a user had a similar problem with Quadra-Fire 32198A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)