Manual Kathrein VOS 952-1G/953-1G

11 pages 8.26 mb
Download

Go to site of 11

Summary
  • Kathrein VOS 952-1G/953-1G - page 1

    Antennen · Electr onic Compact amplifier s VGP 9033-1G/9041 VGF 9030/9040 VGO 939-1G/VGF 939-1G VOS 952-1G/953-1G ...

  • Kathrein VOS 952-1G/953-1G - page 2

    3 "Plug-and-Play" r edefined Ele ctronic setting of all important parameters, automatic levelling (only for VGP 9033-1G/9041) as well as remote configuration via HMS or DOCSIS monitoring ensure the shortest start-up and maintenance times. The copy function enables one to copy all settings and transfer them to another device at the press ...

  • Kathrein VOS 952-1G/953-1G - page 3

    DET AILS, ACCESSORIES, BLOCK DIAGRAM, DELIVER Y ST A TUS 4 Delivery status F-type test socket internal (-20 dB) F-type test socket internal (-20 dB) Output insert position Insert position "Forward 1" e.g. for additional C-line pre-emphasis Connection socket for hand-held unit HTE 10 Insert position for monitoring transponder (not included ...

  • Kathrein VOS 952-1G/953-1G - page 4

    6 7 T echnical Data DESCRIPTION VGO 939-1G/ VGF 939-1G DA T A T ype VGF 9030 VGF 9040 VGP 9033-1G VGP 9041 Order no. 24410108 24410109 24410103 24410054 FORW ARD P A TH Frequency range MHz 85-862 85-862 85-1000 85-862 Gain (at 1000 MHz) dB 33 40 33 40 Return loss dB 19-1.5 dB/oct. Frequency r esponse (85-1000 MHz at 25 °C) dB ± 0.5 Max. output le ...

  • Kathrein VOS 952-1G/953-1G - page 5

    Attenuation or pre-emphasis Current T emperature Ub ICS Monitoring transponder 2 / 0 / 4 dB 2 / 0 / 4 dB 6 / 0 / 12 dB 6 / 0 / 12 dB 5 - 65 MHz 85 - 1006 MHz 85 - 1006 MHz 5 - 65 MHz 4 / 0 / 8 dB T est 3 -10 dB 4 / 0 / 8 dB 0 / -8 dB / "switched-off" Interstage Pre-emphasis Pre-emphasis dB Pre-emphasis 5-65 MHz Internal Attenuation Attenu ...

  • Kathrein VOS 952-1G/953-1G - page 6

    1 1 T echnical Data DESCRIPTION VOS 952-1G/953-1G DA T A T ype VGO 939-1G VGF 939-1G Notes Order no. 24410101 24410100 Locally fed Remotely fed FORW ARD P A TH Frequency range MHz 85-1000 Gain dB 40 Gain setting range, interstage ³ ) dB 32-40 Amplitude response dB ±0.5 85-1000 MHz, at 25 °C Amplitude response (additional, 862-1000 MHz) dB -0.5 a ...

  • Kathrein VOS 952-1G/953-1G - page 7

    1 2 DET AILS, ACCESSORIES, BLOCK DIAGRAM, DELIVER Y ST A TUS Accessories Delivery status 1 3 LED (Power supply function) ) Input insert position e.g. for de-emphasis equaliser Insert position for monitoring transponder (not included in delivery scope) F-type test socket for the return path (-10 dB) F-type test socket bidirectional on input (-20 dB) ...

  • Kathrein VOS 952-1G/953-1G - page 8

    1 4 1 5 DA T A T echnical Data 1) Adjustable with 2 slide switches in 1 dB steps 2) CENELEC: 42 channels 3) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB T ype VOS 952-1G VOS 953-1G Notes Order no. 24410098 24410099 Locally fed Remotely fed FORW ARD P A TH Frequency range MHz 47/85-1000 47/85-1000 Gain ¹) dB 40-32 40- ...

  • Kathrein VOS 952-1G/953-1G - page 9

    1 6 1 7 HTE 10 - Hand-held unit With the HTE 10 hand-held unit one is able to adjust correspondingly equipped devices on site. Using the 'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able to change and set the values on the 4-line display . The display is illuminated and easy to read. Accessories Monito ...

  • Kathrein VOS 952-1G/953-1G - page 10

    EAC 90-1G, 93-1G, 94-1G – T ap-of f cards 1 8 1 9 T ype EAC 90-1G EAC 93-1G EAC 94-1G EBC 90 -1G Order no. 24510116 24510115 24510114 24510113 Frequency range MHz 5-1000 5-1000 5-1000 5-1000 Through loss ¹) 5- 610 MHz dB < 1.3 < 2.1 < 0.5 < 3.6 Through loss ¹) 61 0-8 62 MHz dB < 1.3 < 2.3 < 0.6 < 3.8 Through loss ¹) 86 ...

  • Kathrein VOS 952-1G/953-1G - page 11

    W e are pleased to advise you: 99811514/1/0810/JH/Pf T echnical data subject to modification. T echnical data repr esent typical values. Antennen · Electr onic The pr oducts described must only be installed by qualified specialists. Please consult the provided instruction manuals for the safety instructions that are to be considered during use. KA ...

Manufacturer Kathrein Category Car Amplifier

Documents that we receive from a manufacturer of a Kathrein VOS 952-1G/953-1G can be divided into several groups. They are, among others:
- Kathrein technical drawings
- VOS 952-1G/953-1G manuals
- Kathrein product data sheets
- information booklets
- or energy labels Kathrein VOS 952-1G/953-1G
All of them are important, but the most important information from the point of view of use of the device are in the user manual Kathrein VOS 952-1G/953-1G.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Kathrein VOS 952-1G/953-1G, service manual, brief instructions and user manuals Kathrein VOS 952-1G/953-1G. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Kathrein VOS 952-1G/953-1G.

A complete manual for the device Kathrein VOS 952-1G/953-1G, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Kathrein VOS 952-1G/953-1G by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Kathrein VOS 952-1G/953-1G.

A complete Kathrein manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Kathrein VOS 952-1G/953-1G - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Kathrein VOS 952-1G/953-1G, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Kathrein VOS 952-1G/953-1G, that we can find in the current document
3. Tips how to use the basic functions of the device Kathrein VOS 952-1G/953-1G - which should help us in our first steps of using Kathrein VOS 952-1G/953-1G
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Kathrein VOS 952-1G/953-1G
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Kathrein VOS 952-1G/953-1G in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Kathrein VOS 952-1G/953-1G?

Use the form below

If you did not solve your problem by using a manual Kathrein VOS 952-1G/953-1G, ask a question using the form below. If a user had a similar problem with Kathrein VOS 952-1G/953-1G it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)