Manual Miele da 186

28 pages 1.39 mb
Download

Go to site of 28

Summary
  • Miele da 186 - page 1

    Operating and installation instructions Cooker hood DA 186 To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time. M.-Nr. 07 623 170 e n-G B ...

  • Miele da 186 - page 2

    Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Modes of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Guide to the ...

  • Miele da 186 - page 3

    Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children. Danger of suffocation! Disposal of your old appliance ...

  • Miele da 186 - page 4

    This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time. They contain important information on the safety, i ...

  • Miele da 186 - page 5

    Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. A damaged appliance is dangerous. ~ Before connecting the appliance to the mains supply, make sure that the voltage and frequency details given on the data plate correspond with the on-site electricit ...

  • Miele da 186 - page 6

    ~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ This appliance must not be used in a non-stationary location (e.g. on a ship). ~ In countries where there are areas which may be subject to infestatio ...

  • Miele da 186 - page 7

    In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible. Ventilation can be maintained by air inlets which cannot be blocked, in wind ...

  • Miele da 186 - page 8

    ~ Do not use the cooker hood without the filters in place. This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation. ~ The filters should be regularly cleaned or changed as appropriate. Saturated filters are a fire hazard. See "Cleaning and care". ~ Do not use a steam-cleaner to cle ...

  • Miele da 186 - page 9

    The cooker hood works with . . . air extraction: The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap , the non-return flap supplied must be fitted. This flap is closed when the cooker hood is switched off. No exchange of room and outside air can take place. Wh ...

  • Miele da 186 - page 10

    Guide to the appliance / Operation 10 ...

  • Miele da 186 - page 11

    a Recirculation grille (only for recirculation mode) b Exhaust connection c Adjustable bracket d Vapour canopy to which a furniture door front is fitted e Charcoal filter (extra accessory available to order for recirculation mode) f Hob lighting g Grease filters h Control panel Operation To switch on the fan ^ Open the vapour canopy. The fan will c ...

  • Miele da 186 - page 12

    A range of Miele branded cleaning and conditioning products is available to order from Miele (see back page for details) or via the internet at www.miele-shop.com. , Before carrying out any cleaning or maintenance work, disconnect the cooker hood from the mains supply. , Halogen lamps get very hot during use and remain hot for some time after being ...

  • Miele da 186 - page 13

    Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapours, preventing soiling of the cooker hood. They should be cleaned at least every 3-4 weeks to avoid grease sticking hard to them. , An oversaturated filter is a fire hazard. ^ Release the locking clips on the grease f ...

  • Miele da 186 - page 14

    Charcoal filters If the cooker hood is being used on recirculation mode, two DKF 14-1 charcoal filters must be fitted behind the grease filters. ^ Open the vapour canopy ^ Remove the grease filters. ^ Unwrap the charcoal filters. ^ Position the charcoal filters on either side of the fan as shown, and twist securely into place. ^ Replace the grease ...

  • Miele da 186 - page 15

    Changing a halogen lamp , Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. , Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off. Do not touch the surface directly when changing a lamp, as grease particles from your fingers will a ...

  • Miele da 186 - page 16

    In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – your Miele Dealer or – the Miele Service Department (see back cover for contact details). When contacting the Service Department, please quote the model and serial number of your appliance These are shown on the data plate which ...

  • Miele da 186 - page 17

    * Furniture panel dimensions Connection for air extraction C 150 mm, or C 120 mm with reducing collar. Safety distance between hob and cooker hood The distance betwen the top of the cooker/hob and the bottom of the cooker hood must measure at least 650 mm , unless a greater distance is specified by the manufacturer. If this cooker hood is installed ...

  • Miele da 186 - page 18

    Before installation, it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet. This is particularly crucial when using the cooker hood at the same time as a heating appliance that relies on oxygen from the same room, which could result in the build-up of tox ...

  • Miele da 186 - page 19

    Depth adjustment ^ The depth of the unit "T" can be adjusted from 275 to 360 mm by means of the adjustable brackets. ^ Slightly loosen the screws on the brackets. ^ Then pull the brackets out until you achieve the required depth "T". ^ Tighten the screws up again. ^ To align the depth on the underside of the appliance, loosen th ...

  • Miele da 186 - page 20

    ^ The recirculation grille must be removed when the hood is used in extraction mode. ^ Hang the cooker hood in position using the adjustable brackets. ^ Position the vapour canopy with the furniture door front fitted, and close it. The movement of the vapour canopy can be adjusted if necessary, for instance where a heavy furniture door is fitted. T ...

  • Miele da 186 - page 21

    Height adjustment ^ Using the screws at the back of the adjustable brackets, align the cooker hood height with that of neighbouring units. Turn the screw – anti-clockwise : to raise the appliance. – clockwise : to lower the appliance. ^ If necessary adjust the depth again. Securing the appliance to neighbouring wall units or fitting side panels ...

  • Miele da 186 - page 22

    With air extraction: If the on-site ventilation system does not have a non-return flap, one of the two non-return flaps supplied (for C 150 mm or C 120 mm ducting) must be fitted. –I f C 150 mm ducting is being used, the non-return flap should be fitted onto the exhaust connection. With C 120 mm ducting, first fit the reducing collar supplied ont ...

  • Miele da 186 - page 23

    All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable. Ensure power is not supplied to the appli ...

  • Miele da 186 - page 24

    Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations. Seek approval from th ...

  • Miele da 186 - page 25

    Total connected load ..........1 7 5W Fan motor .................1 3 5W Hob lighting ..............2x2 0W Voltage ................. A C2 3 0V Frequency .................~5 0H z Fuse rating (UK) ................5A Electrical cable length .........1 . 8m Fan performance Extraction power according to EN 61591 Extraction system C 150 mm: Level I ...... ...

  • Miele da 186 - page 26

    26 ...

  • Miele da 186 - page 27

    27 ...

  • Miele da 186 - page 28

    Alteration rights reserved / 3011 M.-Nr. 07 623 170 / 03 ...

Manufacturer Miele Category Ventilation Hood

Documents that we receive from a manufacturer of a Miele da 186 can be divided into several groups. They are, among others:
- Miele technical drawings
- da 186 manuals
- Miele product data sheets
- information booklets
- or energy labels Miele da 186
All of them are important, but the most important information from the point of view of use of the device are in the user manual Miele da 186.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Miele da 186, service manual, brief instructions and user manuals Miele da 186. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Miele da 186.

Similar manuals

A complete manual for the device Miele da 186, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Miele da 186 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Miele da 186.

A complete Miele manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Miele da 186 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Miele da 186, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Miele da 186, that we can find in the current document
3. Tips how to use the basic functions of the device Miele da 186 - which should help us in our first steps of using Miele da 186
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Miele da 186
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Miele da 186 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Miele da 186?

Use the form below

If you did not solve your problem by using a manual Miele da 186, ask a question using the form below. If a user had a similar problem with Miele da 186 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)