Hunter 40135 - page 1
1 Electronic/Mechanical Thermostat Model 40135 installation and operation manual 44017-01 04-01-2008 ...
-
Hunter 40135 - page 2
2 Our T echnical Support Group is available from 8 am to 5 pm CST . They may be reached toll-free at 1-888-830-1326. ...
-
Hunter 40135 - page 3
3 T able of Contents Important Information ....................................... 5 T ools ................................................................. 6 Uninstalling the Existing Unit ............................ 9 Installing the Thermostat ................................ 12 Installing the wall plate ................................... 14 c ...
-
Hunter 40135 - page 4
4 Congratulations! Thank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions. Electronic/Mechanical Thermostat Model 40135 ...
-
Hunter 40135 - page 5
5 This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Air conditioner Electric Furnace This thermostat is not designed for heat pump systems or 1 10/220 V baseboard hea ...
-
Hunter 40135 - page 6
6 This thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ...................................................................................... Small Phillips-head screwdriver ...................................................... ...
-
Hunter 40135 - page 7
7 NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. ...
-
Hunter 40135 - page 8
8 Y RC G W Y RC G W ...
-
Hunter 40135 - page 9
9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV AC system OFF at the main power panel or at the furnace. 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.) 3. Locate, but do ...
-
Hunter 40135 - page 10
10 If your existing thermostat is marked... label the wire with this sticker: RH / R / VR / 4 RH RH 24 V olt RC / VC RC RC 24 V olt Cool Y / C* / M Y Y air conditioning compressor W / H W W heating G / F G G fan * See pg 27 for complete wiring diagram. ...
-
Hunter 40135 - page 11
11 4. Using the provided stickers, label each wire according to the chart. (If the terminals are not labeled, contact a qualied HV AC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identication. *If a wire marked C is present, C may be ...
-
Hunter 40135 - page 12
12 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the new thermostat from the back plate by pulling the two halves apart. Thermostat W all Plate ...
-
Hunter 40135 - page 13
13 W R C Y G ...
-
Hunter 40135 - page 14
14 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, level the wall plate and mark the wall for two holes. 4. Remove the wall plate and drill two 3/16” holes where marked. 5. T ap the plastic anchors in ...
-
Hunter 40135 - page 15
15 RC RH Y G W ...
-
Hunter 40135 - page 16
16 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave t ...
-
Hunter 40135 - page 17
17 HE/HG Switch ...
-
Hunter 40135 - page 18
18 A TT ACHING THE THERMOST A T 4. Locate the HE/HG s w i t c H on the back of the thermostat. Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 5. Insert two fresh AA alkaline batteries. 6. Align the thermostat with the the wall plat ...
-
Hunter 40135 - page 19
19 ...
-
Hunter 40135 - page 20
20 Fan Switch System Switch Set T emperature Slider Thermometer Battery Indicator SY STEM COOL OFF HE A T AU TO ON 3 0 2 0 1 0 9 0 8 0 7 0 6 0 5 0 F C 9 0 8 0 7 0 6 0 5 0 F ...
-
Hunter 40135 - page 21
21 OPERA TION 1. Set the s E t t E m p E r a t u r E s l i d E r to the desired temperature. 2. The s y s t E m s w i t c H determines the operating mode of the thermostat. Select c o o l , o f f , or H E a t . 3. The f a n s w i t c H should normally be located in the a u t o position. T o run the fan continuously , slide the f a n s w i t c H to ...
-
Hunter 40135 - page 22
22 INDICA T ORS AND ADUSTMENT 1. The t H E r m o m E t E r indicates the room temperature. 2. The B a t t E r y i n d i c a t o r displays two stages of battery conditions. The rst warning is the w E a k B a t t E r y w a r n i n G , indicated by the B a t t E r y i n d i c a t o r ashing once approximately every second. When this warning app ...
-
Hunter 40135 - page 23
23 Span Adjust SP AN ...
-
Hunter 40135 - page 24
24 INDICA T ORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o make your system run LONGER, turn the s p a n a d j u s t clockwise. 3. T o make your system run SHORTER, turn the s p a n a d j u s t counter clockwise. 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6 o F - 3 o F. The Span setting r ...
-
Hunter 40135 - page 25
25 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. W ait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit breakers and switches to ensure there is enough power to the system. 1 d. Replace the ...
-
Hunter 40135 - page 26
26 Is there help on the web? Y es. Visit http://www .hunterfan.com for more information. .................................................................................... ......... Can’t I just call someone? Sure. Our T echnical Support Group is available from 8 am to 5 pm CST . They may be reached toll-free at1-888-830- 1326. TROUBLESHOOTING ...
-
Hunter 40135 - page 27
27 G R h W Y F a n R e l a y H e a t / Co ol 2 4 V S u ppl y Co o l Co n t a c t o r H e a t R e l a y o r V a l v e 4 - w i r e H e a t / Co o l S y s t e m G Rc Rh F a n Re l ay He a t 24V Supply W He a t Re l a y or V alve Y Co o l Co n tact or 5-wire H eat/C oo l Sy stem Co o l 24V Supply ...
-
Hunter 40135 - page 28
28 WIRING DIAGRAMS R h W H e a t 2 4 V or M i l l i v o l t S u p pl y H e a t Re l a y o r V a l v e 2 - w i r e H e a t O n l y S y s t e m G R h W H e a t 2 4 V S u ppl y H e a t R e l a y o r V a l v e 3 - w i r e He a t O n l y S y s t e m F a n R e l a y ...
-
Hunter 40135 - page 29
29 G R c Y Co o l Co n t a c t e r Co ol 2 4 V S u ppl y 3 - w i r e Co o l O n l y S y s t e m F a n R e l a y WIRING DIAGRAMS, CONT . ...
-
Hunter 40135 - page 30
30 © 2007 Hunter Fan Company ...