Manual Honeywell W8150

12 pages 1.08 mb
Download

Go to site of 12

Summary
  • Honeywell W8150 - page 1

    PRODUCT DAT A Put Bar Code Here 68-0282-07 Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control APPLICATION The Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control provide fres h air to a home. The control operates a fresh air intake damper and, when necessary , activates the main HV AC blower to efficient ...

  • Honeywell W8150 - page 2

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 2 SPECIFICATIONS Y8150 includes: W8150A Fresh Air V entil ation Control. EARD6 Fresh Air Damper . A T120B T ransformer . Mounting hardware for control. Homeowner information label. W8150 includes: W8150 Fresh Air V entil ation Control. Mounting hardware for co ...

  • Honeywell W8150 - page 3

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 3 68-0282—07 W8150 QUICK GUIDE No. Name Description Function 1G F Equipment fan Allows W8150 to pass thermost at calls and, when necessary , turn on system fan for ventilation. This should be the only connecti on to G on the HV AC equipment. 2R C 24 V ac cooling system powe ...

  • Honeywell W8150 - page 4

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 4 INST ALLATION A fresh air duct and damper must be installed between the outdoors and the return side of the HV AC equipment. The W8150 control will be mounted near th e HV AC system and wired between the thermost at and the fan control. Y ou will need… • ...

  • Honeywell W8150 - page 5

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 5 68-0282—07 Inst alling fresh ai r damper , ducting, and control… 1. Disconnect power from HV AC system. 2. Install the weather hood, du cting, and damper followi ng local practices. Be sure al l duct and insulation seams are tightly sealed. 3. Mount the transformer and ...

  • Honeywell W8150 - page 6

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 6 Measuring airflow… 1. Make sure all HV AC system air filters are clean and installed. 2. Push T est button: • Control opens damper and turns on HV AC fan for three minutes. • A red or green light is flashing; you can now me asure airflow . 3. Follow in ...

  • Honeywell W8150 - page 7

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 7 68-0282—07 Setting the control... 1. Be sure power is turned on. 2. Set the V entilation S tandard on the con trol. 3. Set the bedrooms dial. 4. Set the area (sq f t) dial. 5. Set the airflow (cfm) dial. 6. Press the test button and observe the lights: Green light is flas ...

  • Honeywell W8150 - page 8

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 8 CHECKOUT In this section, make sure the ventilation system is operating correctly . 1. On thermostat, set Fan swit ch to Auto and System switch to Off . 2. Set any remote swi tches throughout the house in the Off position. 3. On the W8150, set the control sw ...

  • Honeywell W8150 - page 9

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 9 68-0282—07 HV AC fan is running all the time Device is set to override • Move switch to On position to allow for automatic opera tion. Remote switch is on • Adjust remote switch to desired position. Thermostat Fan switch is in On position • Normal ope ration. HV AC ...

  • Honeywell W8150 - page 10

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 10 WIRING DIAGRAMS Consult thermo stat Installation Instructions for alternate terminal designations. Fig. 1. Single transformer , conventiona l system. Fig. 2. Dual tran sforme r , conventional system. Fig. 3. Multi-st age conventional sys tem. Fig. 4. Wiring ...

  • Honeywell W8150 - page 11

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 11 68-0282—07 Fig. 5. Wiring hea t pump with emergency heat. Fig. 6. Wiri ng with a PC8900. Fig. 7. Using a remote switch or timer . Fig. 8. W iring to an HR V/ERV . Fig. 9. Wiring an exhaust fan. Wake Room System Fan Heat Auto AM DST Tue Y C RW 2 E G O Y 1 W 1 C RW 2 E G O ...

  • Honeywell W8150 - page 12

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL Automation and Co ntrol Solutions Honeywell Internationa l Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Regi stered T rademark © 201 1 Honeywell Inte rnat ...

Manufacturer Honeywell Category Ventilation Hood

Documents that we receive from a manufacturer of a Honeywell W8150 can be divided into several groups. They are, among others:
- Honeywell technical drawings
- W8150 manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell W8150
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell W8150.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell W8150, service manual, brief instructions and user manuals Honeywell W8150. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell W8150.

Similar manuals

A complete manual for the device Honeywell W8150, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell W8150 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell W8150.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell W8150 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell W8150, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell W8150, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell W8150 - which should help us in our first steps of using Honeywell W8150
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell W8150
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell W8150 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell W8150?

Use the form below

If you did not solve your problem by using a manual Honeywell W8150, ask a question using the form below. If a user had a similar problem with Honeywell W8150 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)