    1 COMMERCIAL ELECTRIC WATER HEATERS Printed in U.S.A. 0704 P ART NO. 195201-000 MODELS DEN AND DEL • Installation • Electrical • Wiring Diagrams • Replacement Parts • Operation • Maintenance • Leakage Checkpoints • Limited W arranty A DIVISION OF A. O. SMITH CORPORA TION McBee, South Carolina, USA w w w .hotwater .com CAUTION TEXT P ...

  • A.O. Smith DEN - page 2

    2 ROUGH-IN DIMENSIONS RECOVER Y CAP ACITIES Element U.S. Gallons/Hr and Litres/Hr at TEMPERA TURE RISE INDICA TED Wattage INPUT F ° 36F° 40F° 54F° 60F° 72F° 80F° 90F° 100F° 108F° 120F° 126F° (Upper/Lower) K W C ° 20C° 22.2C° 30C° 33.3C° 40C° 44.4C° 50C° 55.5C° 60C° 66.6C° 70C° NON-SIMULA T ANEOUS OPERATION /1500 G PH 17 15 1 ...

  • A.O. Smith DEN - page 3

    3 FOREWORD Thank you for buying this energy efficient water heater from A.O. Smith W ater Products Company . We appreciate your confidence in our products. Detailed installation diagrams are in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping suggested. IT IS NECESSARY THA T ALL ...

  • A.O. Smith DEN - page 4

    4 CLEARANCES A minimum clearance of 4” must be allowed for access to replaceable parts such as the thermostats, drain valve and relief valve. Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. FLOOD W ARNING IF THE HEA TER BECOMES IMMERSED IN WA TER UP T O OR ABOVE THE LEVEL ...

  • A.O. Smith DEN - page 5

    5 WIRING DIAGRAMS C-2 CIRCUIT FOR SINGLE ELEMENT HEA TERS EQUIPPED WITH HIGH LIMIT CONTROL Size T emperature Rating of Conductor See T able 310-13 in Code AMG 60° C 75° C M C M (140° F) (167° F) TYPES: TYPES: R U W RH, RHW , RUH, (14-2), (14-2), THW T , TW, THWN, XHHW , U F USE 18 - - - - - - 16 - - - - - - 14 15 15 12 20 20 10 30 30 84 0 4 5 6 ...

  • A.O. Smith DEN - page 6

    6 TYPICAL PIPING CONNECTIONS This page shows typical water heater installations by model designations. † OVER CURRENT PROTECTION MUST BE SUPPLIED IN WA TER HEATER CIRCUIT . CONSUL T LOCAL CODE OR NEC-1984 FOR PROPER INST ALLATI ON . * INST ALL IN ACCORDANCE WITH ALL LOCAL CODES. TEMPERA TURE AND PRESSURE RELIEF V AL VE CAUTION TO REDUCE THE RISK ...

  • A.O. Smith DEN - page 7

    7 OPERA TION CAUTION DO NOT OPERA TE THE HEA TER WITHOUT INST ALLING AN APPROVED TEMPERA TURE AND PRESSURE RELIEF V AL VE IN THE OPENING PROVIDED IN THE T ANK. GROUND THE HEA TER TO GUARD AGAINST ELECTRIC SHOCK FROM THE HEA TER OR W A TER SYSTEM. NEVER OPERA TE THE HEA TER WITHOUT FILLING WITH W A TER PER THE FILLING INSTRUCTIONS. F AILURE TO DO SO ...

  • A.O. Smith DEN - page 8

    8 3. Using a flat tip screwdriver , rotate the adjusting knob to the desired temperature setting. 4. Replace the covers and access panels, and turn on heater electrical supply . V alves for reducing point-of-use temperature by mixing cold and hot water are available (See Figure 5). Also available are inexpensive devices that attach to faucets to li ...

  • A.O. Smith DEN - page 9

    9 service, contact your dealer or utility company . Refer to TEMPERA TURE REGULA TION section. 4. The storage capacity of the heater may have been exceeded by large demands of hot water . 5. If the heater was installed when incoming water temperatures were warm, colder incoming temperatures will create the effect of less hot water . 6. Look for lea ...

  • A.O. Smith DEN - page 10

    10 LEAKAGE CHECKPOINTS Instructions : Use this illustration as a guide when checking for sources of water leakage. Y ou or your dealer may be able to correct what appears to be a problem. NOTE: Cover and Insulation shown removed to reveal tank top Relief V alve T o Open Drain Condensation and dripping may appear on pipes when cold water temperature ...

  • A.O. Smith DEN - page 11

    11 MODELS DEN AND DEL ELECTRIC W A TER HEA TER LIMITED WARRANTY A. 0. Smith Corporation, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater: 1. THE T ANK If the glass-Iined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein ...

  • A.O. Smith DEN - page 12

    12 5621 W . 1 15TH STREET , ALSIP , IL 60803 Phone: 800-433-2545 Fax: 800-433-2515 w w w .hotwater .com e-mail: parts@hotwater .com ...

Manufacturer A.O. Smith Category Water Heater

Documents that we receive from a manufacturer of a A.O. Smith DEN can be divided into several groups. They are, among others:
- A.O. Smith technical drawings
- DEN manuals
- A.O. Smith product data sheets
- information booklets
- or energy labels A.O. Smith DEN
All of them are important, but the most important information from the point of view of use of the device are in the user manual A.O. Smith DEN.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals A.O. Smith DEN, service manual, brief instructions and user manuals A.O. Smith DEN. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product A.O. Smith DEN.

A complete manual for the device A.O. Smith DEN, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use A.O. Smith DEN by users. Manuals are usually written by a technical writer, but in a language understandable to all users of A.O. Smith DEN.

A complete A.O. Smith manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual A.O. Smith DEN - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the A.O. Smith DEN, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the A.O. Smith DEN, that we can find in the current document
3. Tips how to use the basic functions of the device A.O. Smith DEN - which should help us in our first steps of using A.O. Smith DEN
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with A.O. Smith DEN
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of A.O. Smith DEN in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning A.O. Smith DEN?

Use the form below

If you did not solve your problem by using a manual A.O. Smith DEN, ask a question using the form below. If a user had a similar problem with A.O. Smith DEN it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)