Manual Taylor C706

44 pages 1.74 mb
Download

Go to site of 44

Summary
  • Taylor C706 - page 1

    OPERATOR'S MANUAL Model C706 Soft Serve Freezer Original Operating Instructions 056436-M Februar y, 2003 (Ori ginal Publ icat ion) (Up da ted 9 /2 /14 ) ...

  • Taylor C706 - page 2

    Com plete this page for quick r efer ence when ser vic e is requi red: T aylor Dis tributor: Address: Phone: Serv ice: Par ts: Date of Installation: Infor mation found on the data label: Model Number: Seri al Number: Electric al Specs: V oltage Cycle Phase Maximum Fuse S ize: A Minimum Wi re Ampacity : A E 2003 Carrier Com merc ial Refriger ation, ...

  • Taylor C706 - page 3

    T able of Conte nts Mode l C70 6 T able of Contents Section 1 T o the Installer 1 ............................................ Section 2 T o the Operator 4 ........................................... Section 3 S afety 5 .................................................... Section 4 Op erator P arts Iden tification 7 ............................... ...

  • Taylor C706 - page 4

    T able of Conte nts Mode l C70 6 T able of Contents - Page 2 Cleaning 25 ............................................................. Disassemb ly 26 .......................................................... Brush Cleani ng 26 ....................................................... Se ction 7 Impor tant: Operator C heckli st 28 .................. ...

  • Taylor C706 - page 5

    1 Mode l C70 6 T o th e Installer 131 122 Section 1 T o th e Installer The f ollowing infor mation has been included in t he manual as saf ety and regulat ory guidelines. F or complet e inst allation inst ruct ions, please see t he Inst allat ion Checklist . Installer Safety In all ar eas of t he world, equipment should be installed in accor dance ...

  • Taylor C706 - page 6

    2 Mode l C70 6 T o th e Installer 101027 W ater Connecti ons (Water Cool ed Un it s On ly) An adequate c old water supply must be pr ovided wit h a hand shut - off valve. O n t he underside rear of the base pan, two 3/ 8” I. P .S. wat er connect ions for inlet and outlet have been provided f or easy hook - up. 1/2” inside diamet er wat er lines ...

  • Taylor C706 - page 7

    3 Mode l C70 6 T o th e Installer 130809 Supply cor ds us ed with t his unit shall be oil-res istant , sheat hed flex ible c able not light er than ordinary poly chloroprene or ot her equivalent synthet ic elastom er-s heathed cord (Code designation 60245 IEC 57) inst alled with t he proper cor d anc horage t o relieve c onductor s fr om st rain, i ...

  • Taylor C706 - page 8

    4 Mode l C70 6 T o th e Operator 131 122 Sec tion 2 T o the Opera tor The M odel C706 has been caref ully engineered and manuf actur ed to give y ou dependable operation. This unit, when proper ly operated and cared for, will produce a c onsist ent qualit y product. Lik e all mechanic al product s, it will require c leaning and maint enance. A mini ...

  • Taylor C706 - page 9

    5 Mode l C70 6 Safety 130304 Se cti on 3 Sa fety We, at T aylor Company , are concerned about the safet y of t he oper ator when he or s he comes in contac t with t he fr eezer and its part s. T aylor has gone to extr eme effor ts t o design and manuf act ure built - in safet y f eatur es to pr otect both t he operat or and t he serv ice tec hnicia ...

  • Taylor C706 - page 10

    6 Mode l C70 6 Safety 130304 S DO NOT allow unt rained pers onnel t o operat e this mac hine. S DO NOT operat e the freezer unles s all s ervice panels and acc ess doors are res tr ained wit h screws. S DO NOT r emove any int ernal operat ing part s (exam ples: fr eezer door , beater , sc raper blades, et c. ) unless all cont rol s witches are in t ...

  • Taylor C706 - page 11

    7 Mo del C706 Op erato r Parts I den ti ficat io n 140625 Section 4 Operator Parts Identif ication Figur e 1 ITE M DESCRIPTI ON P ART NO. 1 KIT A.- COVER - HOPPER X65368- SP 2 P AN - DRIP 1 1 - 5/8 L ONG 027503 3 PIN- RET AINING- HOPPER COVER 043934 4 P ANEL - SIDE- LEFT 066722- SP2 5 STUD- NOSE CONE 055987 6 SHIELD- SPLASH 049203 7 TRA Y - DRIP *B ...

  • Taylor C706 - page 12

    8 Mode l C70 6 Op erato r Parts I den ti ficat io n 1 10509 Model C706 S ingle Spout D oor and Beater Assem bly Figur e 2 ITE M DESCRIPTI ON P ART NO. 1 DOOR A. - W/BAFFLE X56071- SER 2 HANDLE A.- DRAW-WELDED X56246 3 SCREW-ADJUSTMENT- 5/16- 24 056332 4 O-RI NG-1/ 4 OD X .070W 50 015872 5 PIN - HANDLE - S.S. 055819 6 PLUG - PRIME 028805 7 O- RING - ...

  • Taylor C706 - page 13

    9 Mo del C706 Op erato r Parts I den ti ficat io n 140625 X57029 - XX Pum p A. - Mix S implified Figur e 3 ITE M DESCRIPTI ON P ART NO. 1- 7 PUMP A.- MIX SIMPLIFI ED S.S.- COMPLETE X57029- 14 1 CYLINDER- PUMP HOPPER SOFTSERVE 057943 2 PIN A. - R ET AININ G X55450 3 PIST ON - PUMP- SIMPLIFIED 053526 4 O- RING - 2- 1/8 OD X .139W 020051 5 C A P - V A ...

  • Taylor C706 - page 14

    10 Mode l C70 6 Op erato r Parts I den ti ficat io n 140717 Accessor ies Figur e 4 ITE M DESCRIPTI ON P ART NO. 1 TOOL-O- RING REMOVAL 048260-W HT 2 BRUSH-REAR· BRG·1IN. DX2IN. 013071 3 BRUSH-DOUBLE· ENDED 013072 4 BRUSH-DRAW· VALVE·1” ODX2 013073 5 BRUSH-MI X·PUMP·BODY- 3”X7 023316 6 SANITI ZER STERA SHEEN (JA R) 010425-CS SANITI ZER ST ...

  • Taylor C706 - page 15

    11 Mode l C70 6 Impor tant : T o the Oper ator 041 1 18 Section 5 Important: T o the Operator C706 Figur e 5 ITEM DESCRIP TI ON 1 MIX LOW INDI CA TOR LIGHT 2 MIX OUT INDI CA TOR LIGHT 3 MIX REFRI GERA TION KEY 4 ST ANDBY KEY 5 W ASH KEY 6 AUTO KEY ITEM DESCRIP TI ON 7 PUMP KEY 8 RESET BUTTON - BEA TER MOTOR 9 RESET BUTTON - PUMP 10 POWER SWITCH (T ...

  • Taylor C706 - page 16

    12 Mode l C70 6 Impor tant : T o the Oper ator Sym bol Defi nitions T o bett er c ommunicat e in the Inter national arena, sym bols have replaced words on many of our oper ator switc hes, f unction, and fault indicator s. Y our T aylor equipment is designed with thes e Int ernat ional symbol s. The f ollowing chart identif ies t he symbol def initi ...

  • Taylor C706 - page 17

    13 Mode l C70 6 Impor tant : T o the Oper ator 060518 WA S H K e y When the WASH key is pr essed, t he light comes on. This indicat es beat er motor oper ation. T he ST A NDBY or AUTO m odes mus t be canc elled firs t t o act ivate the W ASH m ode. AUT O Key When the AUTO k ey is pr essed, t he light c omes on. This ind icates that the main refrig ...

  • Taylor C706 - page 18

    14 Mode l C70 6 Impor tant : T o the Oper ator 050126 Feed T ube (B ack - up Option) If the air /mix pump has becom e inoperable because of a miss ing or damaged part , t he operat or can tem porarily oper ate the unit using t he f eed t ube. The product ejection rat e will be slower when the f eed tube is used ins tead of t he air/ mix pum p. Figu ...

  • Taylor C706 - page 19

    15 Mode l C70 6 Op erati ng Pro cedu res 080714 Section 6 Operating Procedures The C706 unit stor es mix in a hopper . The m ix is pumped int o the f reezing cy linder . It has a 3.4 quart (3. 2 liter) c apacity f reezing c ylinder and a 20 quart (18. 9 liter) mix hopper. We begin our inst ruct ions at t he point where we enter the st ore in t he m ...

  • Taylor C706 - page 20

    16 Mode l C70 6 Op erati ng Pro cedu res 0 4 111 8 Inser t t he drive s haft into the f reezing cylinder , hex end fir st, and int o the r ear shell bear ing until t he seal f its secur ely over t he rear s hell bearing. E ngage the hex end fir mly int o the driv e coupling. B e sure t he drive shaft fit s int o the dr ive coupling wit hout binding ...

  • Taylor C706 - page 21

    17 Mode l C70 6 Op erati ng Pro cedu res 0501 12 Slide the t wo o - rings into t he grooves on t he prime plug. Apply an even c oat of T ay lor Lube to t he o- rings and shaft . Figur e 13 Inser t t he prime plug int o the hole in t he top of t he fr eezer door , and pus h down. Figur e 14 Step 4 In stal l the draw val ve. Slide the t hree o - ring ...

  • Taylor C706 - page 22

    18 Mode l C70 6 Op erati ng Pro cedu res 0 4 111 8 Step 8 Inst all t he front drip tray and t he splash shield under the door s pout. Figur e 18 Step 9 Slide the r ear drip pan int o the hole in t he side panel. Slide the pum p drip pan int o the hole in t he bac k panel. Figur e 19 Mix Hopper Assembly Step 1 Inspec t the rubber pump part s. O - r ...

  • Taylor C706 - page 23

    19 Mode l C70 6 Op erati ng Pro cedu res Step 5 Assem ble the pis ton. Slide the r ed o- ring into t he groove of the pist on. DO NOT lubricat e the o - ring. Figur e 23 Step 6 Lightly lubr icat e the inside of t he pump cylinder at t he bott om wit h a paper thin lay er of lubr icant . Figur e 24 Step 7 Inser t t he pist on into t he bott om of t ...

  • Taylor C706 - page 24

    20 Mode l C70 6 Op erati ng Pro cedu res 030206 Step 9 Secur e the pump par ts in posit ion by sliding the ret aining pin through t he cros s holes locat ed at t he bott om of t he pump c ylinder . Figur e 27 Note: T he head of t he ret aining pin should be f acing UP wit h the pump c orrect ly inst alled. Step 10 Assem ble the f eed tube as sembly ...

  • Taylor C706 - page 25

    21 Mode l C70 6 Op erati ng Pro cedu res 080714 Step 13 Slide the lar ge black o - ring and the t wo smaller black o- rings int o the gr ooves on the drive shaf t. Thor oughly lubricat e the o- rings and s haft . DO NO T lubricat e the hex end of t he shaf t. (See F igure 31. ) Figur e 31 Step 14 Inst all t he hex end of the drive shaf t into t he ...

  • Taylor C706 - page 26

    22 Mode l C70 6 Op erati ng Pro cedu res 0 4 111 8 Step 4 Inst all t he pump assem bly . T o posit ion t he pump on the drive hub at the r ear of the mix hopper , align the drive hole in the pist on wit h the driv e crank of t he drive shaft . Secur e the pump in plac e by slipping the pump clip over t he collar of t he pump, m aking sur e the clip ...

  • Taylor C706 - page 27

    23 Mode l C70 6 Op erati ng Pro cedu res 050126 Step 8 When a s teady s tream of sanit izing solut ion is f lowing fr om the prime plug opening in t he bott om of the fr eezer door , pull the draw handle down. Dr aw off all of the sanit izing s olution. Figur e 38 Step 9 Once t he sanit izer s tops f lowing fr om the door spout, raise t he draw han ...

  • Taylor C706 - page 28

    24 Mode l C70 6 Op erati ng Pro cedu res 0 4 111 8 Step 2 Once a stead y stream o f mix starts t o flow from the prime plug opening in the bot tom of the fr eezer door , push down the pr ime plug. Figur e 41 Step 3 When t he mix stops bubbling down into t he fr eezing cylinder, insert the m ix f eed tube. Remov e t he locking clip fr om t he outlet ...

  • Taylor C706 - page 29

    25 Mode l C70 6 Op erati ng Pro cedu res 140717 Dr aining P roduct Fr om the Freez ing Cylinder Step 1 Pres s the A UTO key , cancelling c ompress or and beater m otor operat ion. Pres s the M IX RE F key , cancelling the mix hopper refrige ration system. Step 2 Remove t he hopper cov er and take it to the sink for cleaning. Step 3 If lo cal heal t ...

  • Taylor C706 - page 30

    26 Mode l C70 6 Op erati ng Pro cedu res 080714 Disassem bly Step 1 Be sure t he p ow er swi tch i s i n th e OF F posit ion. No light s should be illuminat ed on the contr ol panel. No te: Fail ur e to fol lo w thi s in struc tion may res ult in severe pers onal injur y to fingers or hands fr om hazardous mov ing parts. Step 2 Remove t he handscr ...

  • Taylor C706 - page 31

    27 Mode l C70 6 Op erati ng Pro cedu res 030102 Note: F or proper br ush cleaning of the adapt er , cap, feed t ube, and or ifice, r efer to t he f ollowing illust ration which indicat es proper br ush usage. Rinse all part s wit h clean, war m wat er . Place the pump part s on a clean, dr y sur face. Step 8 Wipe c lean all exter ior surf aces of t ...

  • Taylor C706 - page 32

    28 Mode l C70 6 Impor tant : Opera tor Che ck list 071205 Section 7 Important: Operator Checklist Dur ing Cl eaning and Sani tizing Clean in g and san it iz in g sched ul es are g overn ed by fe dera l, stat e, or loca l regula tor y agenc ies , and mu st be fol lo w ed accord in gl y . I f the un it has a “ Standby m ode”, it mus t not be use ...

  • Taylor C706 - page 33

    29 Mode l C70 6 Impor tant : Opera tor Che ck list 080714 j 6. If your machine is air cooled, chec k the condenser s for acc umulation of dir t and lint . Dirt y condenser s will reduce the effic iency and capacit y of the mac hine. Condenser s should be cleaned monthly with a sof t brus h. Never use scr ewdrivers or ot her met al probes t o clean ...

  • Taylor C706 - page 34

    30 Mode l C70 6 T r oubleshoot ing Guide Section 8 T roubleshooting G uide PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 1. No product is being dispensed wit h draw valv e open and the m achine in the AUTO mode. a. Freez e- up in mix inlet hole. a. Call servic e technic ian to adjust t he mix hopper tem peratur e. --- b. Beater m otor out on res et. ...

  • Taylor C706 - page 35

    31 Mode l C70 6 T r oubleshoot ing Guide PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 5. The m ix in t he mix hopper is too warm. a. The t emperat ure is out of adjustm ent. a. Call servic e technic ian to adjust t he mix hopper tem peratur e. --- b. The mix hopper cov er is not in pos ition. b. Place t he cover in position. 24 c. The MI X REF light ...

  • Taylor C706 - page 36

    32 Mode l C70 6 T r oubleshoot ing Guide PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 1 1. Pr oduct is not feeding into the f reezing c ylinder . a. Inadequate l evel of m ix in the m ix hopper . a. Fill the mix hopper wit h mix. 24 b. The mix inlet hole is fr ozen up. b. The mix hopper tem peratur e needs adjustm ent. Call serv ice technic ian. --- ...

  • Taylor C706 - page 37

    33 Mode l C70 6 T r oubleshoot ing Guide 030206 PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 15. Excess ive pump c ylinder wear . a. Inadequate or incorr ect lubricat ion of pum p cylinder. a. Follow lubric ation procedur es caref ully . 19 b. Incor rect ball crank rota tio n. b. Contact ser vice technic ian. --- 16. Pitt ing occur ring inside t he ...

  • Taylor C706 - page 38

    34 Mode l C70 6 Parts Rep lacemen t Sch edu l e Section 9 Parts Replacement Schedule P ART DESCRIPTION EVERY 3M O N T H S EVERY 6M O N T H S ANNUALL Y Drive S haft S eal X Scr aper Blade X Fr eezer Door Gas ket X Fr ont Bearing X Beater S hoes X Draw V alv e O - Ring X Prime P lug O - Ring X Feed Tube O - Ring X Air O rific e O - Ring X Whit e Bris ...

  • Taylor C706 - page 39

    35 Mode l C70 6 Limite d War ra nty on Equipm ent 131 122 Section 10 Limited Warranty on Equipment T A Y LO R COM P ANY L IM IT ED WARRANTY ON F REEZ ERS T aylor Com pany , a division of Carrier Commerc ial Refr igeration, Inc . (“ T aylor ”) is pleas ed to pr ovide this lim ited warrant y on new T ay lor-branded f reez er equipment available f ...

  • Taylor C706 - page 40

    36 Mode l C70 6 Limite d War ra nty on Equipm ent 3. Replacement of wear it ems designat ed as Class “000” part s in the T ay lor Operat or ’s Manual. 4. Exter nal hoses, electr ical power supplies , and mac hine grounding. 5. Parts not supplied or designat ed by T ay lor , or damages res ulting fr om their us e. 6. Return t rips or wait ing ...

  • Taylor C706 - page 41

    37 Mode l C70 6 Li mit ed Warran ty on Parts 131 122 Section 1 1 Limited Warranty on Parts T A Y LO R COM P ANY L IM IT ED WARRANTY ON T A YL O R GENUI NE P ARTS T aylor Com pany , a division of Carrier Commerc ial Refr igeration, Inc . (“ T aylor ”) is pleas ed to pr ovide this lim ited warrant y on new T ay lor genuine replacem ent com ponent ...

  • Taylor C706 - page 42

    38 Mode l C70 6 Li mit ed Warran ty on Parts LI MI TED WARRANTY EX CEPT IO NS This limit ed warrant y does not cover: 1. Labor or other cost s incurr ed for diagnosing, r epairing, r emoving, ins talling, s hipping, serv icing or handling of defect ive Part s, replac ement Part s, or new Part s. 2. Normal maint enance, c leaning and lubricat ion as ...

  • Taylor C706 - page 43

    39 Mode l C70 6 Li mit ed Warran ty on Parts LI MI T A TIO N OF W ARRANT Y THI S LI MI TE D W ARRANTY IS EX CLUS IVE AND I S I N LI EU O F AL L O THER WARRANTIE S, CO NDIT I ONS AND/O R REMEDI ES UNDER T HE LA W , I NCLUDI NG ANY I MPL IED WARRANTIE S OR CONDI TI ONS O F MERCHANT ABIL IT Y O R FI TNES S FO R A P ART ICUL AR PURP OSE . T HE ORI GI N ...

  • Taylor C706 - page 44

    Mod e l C706 064288-27 06/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c BLK FIG. 1 GRA/WHT GRN/YEL MIX PUMP MOTOR RESET SWITCH 1 3 1 2 5 4 C S R LINE RELAY RUN CAP. START CAP. COMPRESSOR TERMINAL COVER ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY TO HOOK UP A COMPRESSOR USING A START AND RUN CAPACITOR (CSR) WITH A RELAY. MIX RE ...

Manufacturer Taylor Category Freezer

Documents that we receive from a manufacturer of a Taylor C706 can be divided into several groups. They are, among others:
- Taylor technical drawings
- C706 manuals
- Taylor product data sheets
- information booklets
- or energy labels Taylor C706
All of them are important, but the most important information from the point of view of use of the device are in the user manual Taylor C706.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Taylor C706, service manual, brief instructions and user manuals Taylor C706. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Taylor C706.

Similar manuals

A complete manual for the device Taylor C706, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Taylor C706 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Taylor C706.

A complete Taylor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Taylor C706 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Taylor C706, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Taylor C706, that we can find in the current document
3. Tips how to use the basic functions of the device Taylor C706 - which should help us in our first steps of using Taylor C706
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Taylor C706
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Taylor C706 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Taylor C706?

Use the form below

If you did not solve your problem by using a manual Taylor C706, ask a question using the form below. If a user had a similar problem with Taylor C706 it is likely that he will want to share the way to solve it.

Copy the text from the picture