Manual Oregon Scientific BAR988HG

28 pages 1.15 mb
Download

Go to site of 28

Summary
  • Oregon Scientific BAR988HG - page 1

    Slimline Weather Station Model: BAR988HG / BAR986HG User Manual BAR988HG English Cover R5 OP 8/20/04, 11:26 AM 1 Black ...

  • Oregon Scientific BAR988HG - page 2

    EN 1 CONTENTS Introduction .............................................................. 3 Product Overview .................................................... 4 Front View .............................................................. 4 Back View .............................................................. 5 LCD Display ....................... ...

  • Oregon Scientific BAR988HG - page 3

    EN 2 Backlight ................................................................. 22 Reset System ......................................................... 22 Safety and Care ...................................................... 22 Warnings ................................................................. 22 T roubleshooting ....................... ...

  • Oregon Scientific BAR988HG - page 4

    EN 3 NOTE INTRODUCTION Thank you for selecting the Oregon Scientific TM BAR988HG / BAR986HG Slimline Weather Station. This powerful device bundles time keeping, weather monitoring, indoor and outdoor temperature and humidity readings, barometric trends and altitude adjustment, into a single tool you can use from the convenience of your home. In thi ...

  • Oregon Scientific BAR988HG - page 5

    EN 4 PRODUCT OVERVIEW FRONT VIEW 1. LCD display 2. MODE: Change settings / display 3. MEMOR Y : View current, maximum and minimum temperature / humidity / UV readings 4. HISTOR Y : View historical barometer and UV readings 5. ALARM / : View alarm status; set alarm 6. SNOOZE / LIGHT : Activate 8-minute snooze or backlight 7. SELECT : Switch Areas 8. ...

  • Oregon Scientific BAR988HG - page 6

    EN 5 1. V entilation holes 2. Battery compartment (bottom) 3. AC adaptor socket 4. ° C / ° F switch (in battery compartment) 5. RESET button (in battery compartment) 6. mb / inHg switch (in battery compartment) Y ou can adjust the angle of the clock display as shown below: BACK VIEW 2 1 3 4 5 6 BAR988HG English R5 OP 8/20/04, 11:25 AM 5 Black ...

  • Oregon Scientific BAR988HG - page 7

    EN 6 LCD DISPLA Y 1. Weather Forecast Area: Animated weather forecast 2. T emperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings 4. Clock / Alarm / Calendar Area: Radio-controlled clock; alarms; ca ...

  • Oregon Scientific BAR988HG - page 8

    EN 7 Weather Forecast Area 1. Low battery icon for main unit 2. AC adaptor icon - displays when unplugged 3. Weather display 1 2 3 T emperature / Humidity / Comfort Zone Area 1. Selected Area icon 2. T emperature trend 3. Channel number (1-5) / reception status 4. Low battery icon for remote sensor 5. Humidity trend 6. MAX / MIN temperature 7. T em ...

  • Oregon Scientific BAR988HG - page 9

    EN 8 UVI / Barometer Area 1. Barometric pressure is showing 2. UV is showing 3. Low battery icon for UV sensor 4. UVI value is showing 5. UV exposure time countdown has started 6. UV index level 7. UV exposure time for user 8. Barometer / UV chart 9. SPF applied to user for UV exposure 10. User skin type for UV exposure 1 1. User no. (for UV Mode) ...

  • Oregon Scientific BAR988HG - page 10

    EN 9 REMOTE SENSOR (RTGR328N) 1 2 3 1. LCD display 2. LED status indicator 3. V entilation duct 1 4 5 6 7 2 3 1. Signal reception 2. Channel number 3. Low battery icon 4. T ime 5. T emp ( ° C or ° F) 6. Humidity % 7. T emp / Humidity BAR988HG English R5 OP 8/20/04, 11:25 AM 9 Black ...

  • Oregon Scientific BAR988HG - page 11

    EN 10 GETTING ST ARTED BA TTERIES Batteries are supplied with this product: • Main unit 4 x UM-4 (AAA) 1.5V • Remote unit 2 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery c ...

  • Oregon Scientific BAR988HG - page 12

    EN 11 It is recommended that you use alkaline batteries with this product for longer performance. NOTE UNIT LOCA TION Main Weather Forecast Area Remote T emperature / Humidity Area UV Sensor UVI / Barometric Pressure Area AC ADAPT OR (MAIN UNIT) The batteries serve as a back-up power supply . For continuous use, please install the AC adaptor at the ...

  • Oregon Scientific BAR988HG - page 13

    EN 12 SWITCH OPTION Channel If you are using more than one sensor , select a different channel for each sensor . Radio Signal Format EU (DCF) / UK (MSF) 4. Press RESET . Then set the temperature unit. SWITCH OPTION T emp ° C / ° F T o fold out the stand: 1 2 For best results: • Insert the batteries and select the unit, channel, and radio signal ...

  • Oregon Scientific BAR988HG - page 14

    EN 13 The transmission range may vary and is subject to the receiving range of the main unit. Y ou may need to experiment with various locations to get the best results. SENSOR DA T A TRANSMISSION Data is sent from the sensor(s) every 60 Seconds. The reception icon shown in the T emperature / Humidity Area indicates the status. NOTE SEARCH FOR SENS ...

  • Oregon Scientific BAR988HG - page 15

    EN 14 RADIO-CONTROLLED CLOCK The time and date are automatically updated by radio- controlled clock signals from official time-keeping organizations in Frankfurt (Germany) and Rugby (England) unless you disable this feature. The signals are collected by the remote sensor (RTGR328N) whenever it is within 1500 km (932 miles) of a signal. Initial rece ...

  • Oregon Scientific BAR988HG - page 16

    EN 15 RF clock disabled: SET CLOCK Y ou only need to do this if you have disabled the radio- controlled clock, or if you are too far from a RF signal. 1. Press SELECT to navigate to the Clock Area. will show next to the Area. 2. Press and hold MODE for 2 seconds. 3. Select the time zone offset hour (+ / -23 hours), 12 / 24 hour format, hour , minut ...

  • Oregon Scientific BAR988HG - page 17

    EN 16 SET PRE-ALARM The Pre-Alarm can be set to sound 15, 30, 45, or 60 minutes before the Daily Alarm. It will sound whenever the recorded temperature from Channel 1 Sensor falls to 2 ° C (35.6 ° F) or below . For example, if you set the alarm to 7:00 AM, and the Pre-Alarm to 45 minutes, the Pre-Alarm will sound at 6:15 AM provided the outdoor t ...

  • Oregon Scientific BAR988HG - page 18

    EN 17 Barometric data is shown in 2 areas at the bottom of the display . The upper area shows a 24-hour bar chart. The lower area shows current and historical readings. SELECT MEASUREMENT UNIT Slide the m b / i n H g switch (in the clock battery compartment), to change the display unit. VIEW BAROMETER HISTOR Y Navigate to the Barometer Area. Then p ...

  • Oregon Scientific BAR988HG - page 19

    EN 18 3. Press UP or DOWN to set the altitude in 10-metre increments (-100m to 2500m). 4. Press HISTOR Y to confirm. WEA THER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius. The forecast is based on barometric pressure trend readings. The top area shows an animated icon indicating the foreca ...

  • Oregon Scientific BAR988HG - page 20

    EN 19 • UVI Danger Alert when UV Index reaches unsafe levels. UV data is shown in the same area as the Barometer . Press SELECT to navigate to the Barometer Area, then press MODE to display the UV icon and data. Refer to the UVR138 User Manual for more information and see below to learn about the new additional UV features. NEW ADDITIONAL UV FEA ...

  • Oregon Scientific BAR988HG - page 21

    EN 20 The UV sensor must be activated before you try and set the additional features. Please refer to the UVR138 User Manual for more information. TEMPERA TURE AND HUMIDITY The weather station can display the following information from any of the 5 remote sensors: • Current, minimum, and maximum temperatures and relative humidity percentages. • ...

  • Oregon Scientific BAR988HG - page 22

    EN 21 TEMPERA TURE AND HUMIDITY TREND The trend lines are shown next to the temperature and humidity readings. COMFORT ZONE The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements. TREND RISING STEADY F ALLING TEMPERA TURE HUMIDITY HEA T INDEX The Heat Index advises 4 levels of warning if th ...

  • Oregon Scientific BAR988HG - page 23

    EN 22 BACKLIGHT Press SNOOZE / LIGHT to illuminate the backlight for 8 seconds. RESET SYSTEM The RESET button is located at the bottom of the unit. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote unit or radio-controlled clock). When yo ...

  • Oregon Scientific BAR988HG - page 24

    EN 23 TROUBLESHOOTING SPECIFICA TIONS Main Unit Dimensions L x W x H 120 x 86 x 188 mm (4.72 x 3.39 x 7.40 inches) Weight 376 grams (0.83 lbs) without battery Remote Unit Dimensions L x W x H 70 x 24.5 x 1 16 mm (2.76 x 0.96 x 4.57 inches) Weight 108 grams (0.24 lbs) without battery T emperature Unit ° C or ° F Indoor Range -5 ° C to 50 ° C (23 ...

  • Oregon Scientific BAR988HG - page 25

    EN 24 Comfort 40% to 70% Memory Min / max Barometer Unit mb / hPa or inHg Resolution 1 mb (0.03 inHg) Altitude -100 to 2500 metres (-328 to 2734 feet) Display Sunny (day / night), partly cloudy (day / night), cloudy , rainy , snowy Remote Unit (RTGR328N) RF frequency 433 MHz Range Up to 70 metres (230 feet) with no obstructions T ransmission Approx ...

  • Oregon Scientific BAR988HG - page 26

    EN 25 ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact in ...

  • Oregon Scientific BAR988HG - page 27

    EN 26 EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Applie ...

  • Oregon Scientific BAR988HG - page 28

    © 2004 Oregon Scientific. All rights reserved. 086-003590-014 BAR988HG English Back R5 OP 8/20/04, 11:26 AM 1 Black ...

Manufacturer Oregon Scientific Category Weather Radio

Documents that we receive from a manufacturer of a Oregon Scientific BAR988HG can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- BAR988HG manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific BAR988HG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific BAR988HG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific BAR988HG, service manual, brief instructions and user manuals Oregon Scientific BAR988HG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific BAR988HG.

A complete manual for the device Oregon Scientific BAR988HG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific BAR988HG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific BAR988HG.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific BAR988HG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific BAR988HG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific BAR988HG, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific BAR988HG - which should help us in our first steps of using Oregon Scientific BAR988HG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific BAR988HG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific BAR988HG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific BAR988HG?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific BAR988HG, ask a question using the form below. If a user had a similar problem with Oregon Scientific BAR988HG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)