Manual Lumex Syatems AQ1000

16 pages 0.69 mb
Download

Go to site of 16

Summary
  • Lumex Syatems AQ1000 - page 1

    AQ1000 / AQ2000 AL TERNA TING PRESSURE BUBBLE P AD AND PUMP SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. The latest version of this manual can be found online at www.grahameld.com. AQ1000-INS-LAB-RevD13 ...

  • Lumex Syatems AQ1000 - page 2

    2 AQ1000-INS-LAB-RevD13 CONTENTS INTRODUCTION ...................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION ...................................................................... 3 DANGER ....... ...

  • Lumex Syatems AQ1000 - page 3

    AQ1000-INS-LAB-RevD13 3 INTRODUCTION Use this manual for setup and operation of the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System. Read all instructions befor e using the pad and pump system. Save this manual for futur e r eference. INTENDED USE OF THIS DEVICE The intended use of the Alternating Pr essur e Pad and Pump System, ...

  • Lumex Syatems AQ1000 - page 4

    4 AQ1000-INS-LAB-RevD13  CAUTION:Indicatesapotentialhazardorunsafe practicethat,ifnotavoided,couldresultinminoror moderatepersonalinjury . s  NOTICE:Indicatesapotentialhazardorunsafepractice that,ifnotavoided,couldresultinproductorpr ...

  • Lumex Syatems AQ1000 - page 5

    AQ1000-INS-LAB-RevD13 5  W ARNING:Neveroperatethisproductif a) ithasadamagedcordorplug. b) itisnotworkingproperly . c) ithasbeendroppedordamaged. d) ithasbeendroppedintowater .  ReturntheproducttoyourGraham-Fieldauthorized? ...

  • Lumex Syatems AQ1000 - page 6

    6 AQ1000-INS-LAB-RevD13 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Grounding terminal Class II (for UL only) Disposal of Electrical & Electronic Equipment (WEEE): Do not treat ...

  • Lumex Syatems AQ1000 - page 7

    AQ1000-INS-LAB-RevD13 7 PRODUCT DESCRIPTION B UBBLE P AD AND PUMP SY STEM bubble pad and pump system air tubes bubble pad pump PUMP pump (AQ2000 shown) front panel wire hangers fuses (220V only) air tube connectors ...

  • Lumex Syatems AQ1000 - page 8

    8 AQ1000-INS-LAB-RevD13 FRONT P ANEL AQ1000 AQ1000 pump front panel ON/OFF switch air tube connectors AQ2000 AQ2000 pump front panel ON/OFF switch pressur e control dial Fr ont panel pr essur e contr ol dial (AQ2000 only) : The pr essur e control dial contr ols the air pr essure output. T o incr ease pr essure, turn the dial clockwise. T o decre ...

  • Lumex Syatems AQ1000 - page 9

    AQ1000-INS-LAB-RevD13 9 INST ALLA TION UNP ACKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor . 2. Remove all loose packing fr om the carton. 3. Car efully r emove all components from the carton. 4. Inspect all component ...

  • Lumex Syatems AQ1000 - page 10

    10 AQ1000-INS-LAB-RevD13 5. Connect one end of the air tubes to the bubble pad: slide the ends of the air tubes over the connectors on the top of the foot end of the bubble pad. 6. Connect the other end of the air tubes to the pump connectors; ensur e that the ends of the air tubes ar e rmly tted over the bubble pad and pump connectors bef ...

  • Lumex Syatems AQ1000 - page 11

    AQ1000-INS-LAB-RevD13 11 OPERA TION 1. T urn the ON/OFF switch to the ON position. The pump will begin to deliver air into the bubble pad. 2. Replace all sheets, blankets, and pillows on the bed. Info: if the pressure level seems low , check for any leakage in the air tubes or bubble pad. Replace any damaged tubes. If necessar y , contact your G ...

  • Lumex Syatems AQ1000 - page 12

    12 AQ1000-INS-LAB-RevD13 MAINTENANCE CLEANING Perform the following cleaning pr ocedur es before use and as necessar y thereafter . Pump W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away from dust. Air dr y . s  NOTICE:Donotusephenolicproductsorcorrosiveor powderedcleanserstoclea ...

  • Lumex Syatems AQ1000 - page 13

    AQ1000-INS-LAB-RevD13 13 Fuse replacement (220V system onl y) tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . fuse location fuse fuse cover 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e above). 3. Insert a new fuse ...

  • Lumex Syatems AQ1000 - page 14

    14 AQ1000-INS-LAB-RevD13 SPECIFICA TIONS Model AQ1000 (Standard) AQ2000 (Delux e) P ow er Supply 120V : 120V AC, 60 Hz, 1A 220V : 230V AC, 50 Hz, 7W Fuse Rating 120V : N/A 220V : T1A, 250V Pressur e 1.9 psi (13.10 kPa) 1.0 - 2.0 psi (6.89-13.79 kPa) Air Output 120V : 4.5 LPM 120V : 4-5 LPM 220V : 5.0 LPM 220V : 5-6 LPM Cyc le Time 120V : 5 min. ...

  • Lumex Syatems AQ1000 - page 15

    AQ1000-INS-LAB-RevD13 15 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System for defects in workmanship and materials for the terms listed below . Pump: one year Pad: 90 days If a pr oduct is deemed to be under warranty , GF Health Pr oducts, Inc. shall pr ovide, at its option, (1) r e ...

  • Lumex Syatems AQ1000 - page 16

    GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 tel: 770-368-4700 fax: 770-368-2386 www .grahamfield.com © 2008 GF Health Products, Inc. ...

Manufacturer Lumex Syatems Category Marine Instruments

Documents that we receive from a manufacturer of a Lumex Syatems AQ1000 can be divided into several groups. They are, among others:
- Lumex Syatems technical drawings
- AQ1000 manuals
- Lumex Syatems product data sheets
- information booklets
- or energy labels Lumex Syatems AQ1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lumex Syatems AQ1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lumex Syatems AQ1000, service manual, brief instructions and user manuals Lumex Syatems AQ1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lumex Syatems AQ1000.

A complete manual for the device Lumex Syatems AQ1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lumex Syatems AQ1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lumex Syatems AQ1000.

A complete Lumex Syatems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lumex Syatems AQ1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lumex Syatems AQ1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lumex Syatems AQ1000, that we can find in the current document
3. Tips how to use the basic functions of the device Lumex Syatems AQ1000 - which should help us in our first steps of using Lumex Syatems AQ1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lumex Syatems AQ1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lumex Syatems AQ1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lumex Syatems AQ1000?

Use the form below

If you did not solve your problem by using a manual Lumex Syatems AQ1000, ask a question using the form below. If a user had a similar problem with Lumex Syatems AQ1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture