Manual Chicago Electric 90300

20 pages 4.67 mb
Download

Go to site of 20

Summary
  • Chicago Electric 90300 - page 1

    GENERA T OR 9 HP R OBIN ® ELECTRIC ST AR T Model 90300 OPERA TING INSTRUCTIONS ® 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .harborfreight.com Cop yright © 2003 by Harbor F reight T ools ® . All r ights reser v ed. No por tion of this manual or any ar twork contained herein may be reproduced in an y shape o ...

  • Chicago Electric 90300 - page 2

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 2 PR ODUCT SPECIFICA TIONS Item Description Electrical Requirements 4,500W Maximum Output; 4,000W Continuous Output 20 AMPs @ 120V / 20 AMPs @ 240V 60 Hz Output 120V Dual Outlet: 20 AMP , 3 Prong Grounded 120/240V Outlet: 20 AMP, 4 Prong T wistloc k (L14-20) Ov er load Protection: ...

  • Chicago Electric 90300 - page 3

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 3 GENERAL SAFETY RULES W ARNING! READ AND UNDERST AND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock, fire, and/or serious injury . SA VE THESE INSTR UCTIONS WORK AREA 1. Keep your work area clean and well lit. Cluttered benches and da ...

  • Chicago Electric 90300 - page 4

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 4 7. Do not expose generator s to rain or wet conditions. W ater enter ing a generator will increase the risk of electr ic shock. 8. Do not abuse P ower Cor ds. Ne ver use a P ower Cor d to carry any tool or pull the Plug from an outlet. Keep P ower Cor ds away fr om heat, oil, sha ...

  • Chicago Electric 90300 - page 5

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 5 19. Disconnect the negative battery cable from the battery and remove the Ignition K ey bef ore making any adjustments, changing accessories, or storing the generator . Such pre v entive saf ety measures reduce the r isk of star ting the generator accidentally . 20. Store idle ge ...

  • Chicago Electric 90300 - page 6

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 6 2. Use ey e and hearing protection. W ear ANSI approv ed saf ety impact ey e goggles and hearing protection when using this product. ANSI approved safety impact eye goggles and hear ing protectors are a v ailable from Harbor F reight T ools. 3. Dress safely . Do not wear loose cl ...

  • Chicago Electric 90300 - page 7

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 7 manual cannot cov er all possible conditions and situations that ma y occur . The operator must understand that common sense and caution are factors which cannot be built into this product, b ut must be supplied by the operator . Installation Precautions: 1. W ARNING! Bef ore usi ...

  • Chicago Electric 90300 - page 8

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 8 11. For trailer installation, the Generator should be mounted on the center point of the trailer , ov er the wheels. 12. Install sound- and weatherproofing only while it is not raining or snowing to avoid trapping moisture within the Generator’ s enclosure. Fire And Explosion P ...

  • Chicago Electric 90300 - page 9

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 9 2 . Check f or damaged par ts. Before using the Generator , any par t that appears damaged should be carefully check ed to deter mine that it will operate proper ly and perf orm its intended function. Check f or alignment and binding of moving par ts, any brok en par ts or mounti ...

  • Chicago Electric 90300 - page 10

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 10 Electrical Precautions: 1. All connections and conduits from the Generator to the load must only be installed b y trained and licensed electricians, and in compliance with all rele vant local, state , and feder al electr ical codes and standards, and other regulations where appl ...

  • Chicago Electric 90300 - page 11

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 11 INST ALLA TION 1. NO TE: Pr ior to powering tools and equipment, mak e sure the Generator’ s rated voltage, wattage, and amperage capacity (120V/ 20 AMPs and 240V/ 20 AMPs) is adequate to supply all electrical loads that the unit will power . If po wering exceeds the Generator ...

  • Chicago Electric 90300 - page 12

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 12 GENERAL LOCA TION 1. It is recommended to locate and install the Generator in a protected outdoor area where cooling air is readily av ailable (see previous warning section) . 2. Install the Generator so that the air inlets and outlets are not bloc ked b y obstructions such as b ...

  • Chicago Electric 90300 - page 13

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 13 OPERA TING INSTR UCTIONS NO TE: For additional ref erences to the par ts listed in the follo wing pages, ref er to the Assembly Diagram on page 19. T o Install A Batter y: 1. NO TE: The Generator requires the installation of a 12 v olt batter y (not included). The battery must b ...

  • Chicago Electric 90300 - page 14

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 14 Pre-Start Checks: 1. NO TE: Dur ing operation, it ma y be necessar y to ref er to the Engine manuf acturer’ s Operation, Maintenance , and P ar ts manual (included) f or detailed inf or mation about star ting, r unning, and stopping the Engine. 2 . Check to mak e sure the Engi ...

  • Chicago Electric 90300 - page 15

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 15 T o Star t The Generator: 1 . T ur n the Fuel V alve (31) to its ver tical “OPEN” position. (See Figure F .) 2 . Mov e the Engine’ s Choke all the wa y to the left to its “ST AR T” position. (See Figure F .) 3. T ur n the Engine’ s “ON/OFF” switch to its “ ON? ...

  • Chicago Electric 90300 - page 16

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 16 P o wering T ools And Equipment: 1. Prior to powering tools and equipment, make sure the Gener ator’ s rated v oltage, wattage, and amperage capacity (120V/ 20 AMP and 240V/ 20 AMP) is adequate to supply all electrical loads that the unit will power . If powering e xceeds the ...

  • Chicago Electric 90300 - page 17

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 17 INSPECTION, MAINTENANCE, AND CLEANING 1. NO TE: Prev entative maintenance procedures and frequency will v ar y depending on the amount of Generator use. Ref er to the Engine manuf acturer’ s Operation, Maintenance , and P ar ts manual (included) f or detailed information regar ...

  • Chicago Electric 90300 - page 18

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 18 REV 06/04; 12/04; 01/05; REV 03/06 P ARTS LIST WIRING DIA GRAM 20 20 ...

  • Chicago Electric 90300 - page 19

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 19 ASSEMBL Y DIA GRAM 33 32 31 30 29 28 27 26 25 24 22 21 20 19 23 18 17 16 15 14 13 12 11 10 9 7 6 5 8 4 3 2 1 40 43 45 44 42 41 39 46 47 48 38 37 36 35 34 NO TE: Some par ts are listed and shown for illustr ation pur poses only , and are not availab le individually as replacement ...

  • Chicago Electric 90300 - page 20

    SKU 90300 For technical questions, please call 1-800-444-3353. PAGE 20 1 YEAR WARRANTY Harbor Freight T ools Co . makes e ve r y effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from def ects in materials and wo r kmanship for the period of one year from ...

Manufacturer Chicago Electric Category Portable Generator

Documents that we receive from a manufacturer of a Chicago Electric 90300 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 90300 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 90300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 90300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 90300, service manual, brief instructions and user manuals Chicago Electric 90300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 90300.

A complete manual for the device Chicago Electric 90300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 90300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 90300.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 90300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 90300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 90300, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 90300 - which should help us in our first steps of using Chicago Electric 90300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 90300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 90300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 90300?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 90300, ask a question using the form below. If a user had a similar problem with Chicago Electric 90300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)