  • Sharp GS-XP27FR - page 1

    GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR AE-X7FR AE-X9FR AE-X12FR GU-XR18FR GU-XR24FR GU-XR27FR FLOOR/CEILING TYPE ROOM AIR CONDITIONER OPERA TION MANUAL TIPO DE SUELO/TECHO ACONDICIONADOR DE AIRE P ARA HABIT ACIÓN MANUAL DE INSTRUCCIONES TIPO DI P A VIMENTO/SOFFITT O C ...

  • Sharp GS-XP27FR - page 2

    GS-XP07FR_Eng.p65 05.4.19, 5:05 PM 2 A. Information on Disposal for Users (p ri v ate households) 1. In the European Un ion Attention: If you w ant to dispose of this equip ment, please do not use the ordinar y dust bin! Used electrical a nd electronic equip m en t must be treated sep arately and in accordance w i th legislation that requires prope ...

  • Sharp GS-XP27FR - page 3

    ENGLISH E-1 ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. • IMPORTANT SAFETY INSTRUCTIONS ..... E-1 • ADDITIONAL NOTES ON OPERATION ............. E-3 • TIPS ON SAVING ENERGY ........................ E-3 • PART NAMES .............................................. E-4 ...

  • Sharp GS-XP27FR - page 4

    IMPORT ANT SAFETY INSTRUCTIONS CAUTIONS FOR USE 1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an exten ...

  • Sharp GS-XP27FR - page 5

    ENGLISH INDOOR TEMP. OUTDOOR TEMP. COOLING upper limit 32 ˚ C D.B. 43 ˚ C D.B. 23 ˚ C W.B. - lower limit 21 ˚ C D.B. 21 ˚ C D.B. 15 ˚ C W.B. - HEATING upper limit 27 ˚ C D.B. 24 ˚ C D.B. - 18 ˚ C W.B. lower limit 20 ˚ C D.B. -7 ˚ C D.B. - -8 ˚ C W.B. ADDITIONAL NOTES ON OPERA TION OPERATING TEMPERATURE RANGE • The built-in protective ...

  • Sharp GS-XP27FR - page 6

    P ART NAMES 1 Outlet (Air) 2 Vertical Adjustment Louvres 3 Horizontal Adjustment Louvres 4 Indicator Panel 5 Air Filters 6 Intake Grille 7 Inlet (Air) 8 Remote Control 9 OPERATION Lamp (red ) 0 TIMER Lamp (orange ) q PLASMACLUSTER Lamp (blue) w RECEIVER Window e AUX. Button r Inlet (Air) t Interconnecting Cord and Refrigerant Tube y Drainage Hose u ...

  • Sharp GS-XP27FR - page 7

    ENGLISH REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 ON/OFF Button 5 THERMOSTAT Button 6 FULL POWER Button 7 MODE Button 8 ONE-HOUR OFF TIMER Button 9 TIMER ON Button (for setting the timer) 0 TIMER OFF Button (for setting the timer) q TIME ADVANCE Button w TIME REVERSE Button e FAN Button r TIMER SET/CAN ...

  • Sharp GS-XP27FR - page 8

    1 Remove the remote control cover. 2 Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00" when batteries are prop- erly installed. 3 Reinstall the cover. USING THE REMOTE CONTROL E-6 NOTES: • The battery life is approximately one year in normal use. • W ...

  • Sharp GS-XP27FR - page 9

    ENGLISH E-7 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the sig ...

  • Sharp GS-XP27FR - page 10

    SWING FAN MODE SET/C 1h Press the THERMOSTAT button to set the desired temperature. • In the AUTO and DRY modes, the tem- perature can be changed in 1°C incre- ments within the range of 2°C higher to 2°C lower from the temperature auto- matically determined by the air conditioner. • In the COOL and HEAT modes, the tempera- ture can be set wi ...

  • Sharp GS-XP27FR - page 11

    ENGLISH E-9 During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. MODE CHANGEOVER During seasons when you need COOLING at daytime and HEATING at night, or if the room temperature should become extremely higher than the temperature setting, due to supplementary heating equipmen ...

  • Sharp GS-XP27FR - page 12

    E-10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION HOW TO ADJUST THE AIR FLOW DIRECTION HEAT mode COOL and DRY modes The adjustment range is narrower the SWING range in order to prevent con- densation from dripping. The range is wide so the air flow can be directed toward the floor. Hold the horizontal adjustment louvre as shown in t ...

  • Sharp GS-XP27FR - page 13

    ENGLISH E-1 1 FULL POWER OPERA TION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. 1 Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”. • The orange TIMER lamp ( ) on the unit will light up. • The unit will stop oper ...

  • Sharp GS-XP27FR - page 14

    1 Press the TIMER OFF ( ) button. 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will light. ...

  • Sharp GS-XP27FR - page 15

    ENGLISH 1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will ...

  • Sharp GS-XP27FR - page 16

    E-14 1 TIPS ABOUT PLASMACLUSTER OPERA TION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. PLASMACLUSTER OPERA TION 1 During operation, press the PLASMACLU ...

  • Sharp GS-XP27FR - page 17

    ENGLISH MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the u ...

  • Sharp GS-XP27FR - page 18

    CLEANING THE FIL TERS E-16 MAINTENANCE The air filters should be cleaned every two weeks. 1 TURN OFF THE UNIT 2 OPEN THE INTAKE GRILLE 1 Slide the stoppers to the left ( OPEN ). Two stoppers are provided for each the intake grille. 2 Gently pull and open the intake grille. 3 REMOVE THE AIR FILTERS Push both projections on the air fil- ters slightly ...

  • Sharp GS-XP27FR - page 19

    ENGLISH IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL Check whether the remote con- trol batteries have become old and weak. Try to send the signal again with the remote control pointed prop- erly towards the unit’s signal re- ceiver window. Check whether the remote con- trol batteries are installed with the polarities properly aligned. ...

  • Sharp GS-XP27FR - page 20

    SHARP CORPORA TION OSAKA, JAPAN TINSEA417JBRZ TH 05D- 1 Printed in Thailand GS-XP07FR_Eng.p65 05.4.1, 4:42 PM 20 ...

Manufacturer Sharp Category Air Conditioner

Documents that we receive from a manufacturer of a Sharp GS-XP27FR can be divided into several groups. They are, among others:
- Sharp technical drawings
- GS-XP27FR manuals
- Sharp product data sheets
- information booklets
- or energy labels Sharp GS-XP27FR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sharp GS-XP27FR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sharp GS-XP27FR, service manual, brief instructions and user manuals Sharp GS-XP27FR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sharp GS-XP27FR.

Similar manuals

A complete manual for the device Sharp GS-XP27FR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sharp GS-XP27FR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sharp GS-XP27FR.

A complete Sharp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sharp GS-XP27FR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sharp GS-XP27FR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sharp GS-XP27FR, that we can find in the current document
3. Tips how to use the basic functions of the device Sharp GS-XP27FR - which should help us in our first steps of using Sharp GS-XP27FR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sharp GS-XP27FR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sharp GS-XP27FR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sharp GS-XP27FR?

Use the form below

If you did not solve your problem by using a manual Sharp GS-XP27FR, ask a question using the form below. If a user had a similar problem with Sharp GS-XP27FR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)