  • Carrier 42S - page 1

    Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No . 04-53 420004-01 Printed in U .S .A. Fo rm 42-3SI Pg 1 12-09 Replaces: 42-2SI Installation, Star t-Up and Ser vice Instr uctions CONTENTS Page SAFETY CONSIDERA TIONS . . . . . . . . . . . ...

  • Carrier 42S - page 2

    2 Table 1 — Physical Data — 42C Series Units *Calculate opera ting weight of unit: shipp ing weight + coil wat er weight x number of coil ro ws. †42CF applies t o sizes 04 to 10. ** Filter size f or return-air grille location. ††Filter size if located in return-air plenum. ***With electric heater and bottom return, the 42CF unit fi lter w ...

  • Carrier 42S - page 3

    3 Table 3 — Physical Da ta — 42D Series Units *Calculate Operating W eight of unit: Shipping W eight + Coil W ater W eight x Number of Coil Rows . Table 4 — Physica l Data — 42 S Series Units *Calculate Operat ing Weigh t of Unit: Shipping W ei ght + Coil W ater W eight x Number of Coil Rows. †42SJ units require two filte rs. PRE-INST ALL ...

  • Carrier 42S - page 4

    4 LEGEND 1— Junction Bo x (remote mount) 2— Fle xible Metal Conduit 3— Drain Conn, 7 / 8 -in. OD 4 — T ell-T ale Drain Conn, 5 / 8 -in. OD (optional) 5— Drip Lip (optional) 6— Hanger Slots (4), Rubber Grommet has 3 / 8 -in. Diameter Hole 7— Supply Duct Collar , 1-in. 8— Air V ent, 1 / 8 -in. MPT 9— Return Conn, 5 / 8 -in. OD 10 ? ...

  • Carrier 42S - page 5

    5 LEGEND 1— Junction Bo x (remote mount) 2— Fle xible Metal Conduit 3 — Str ip Heater High Limit 4 — Electr ic Strip Heat er Element 5 — T ell-T ale Drain Conn, 5 / 8 -in. OD (optional) 6— Drain Conn, 7 / 8 -in. OD 7— Drip Lip (optional) 8— Supply Duct Collar , 1-in. 9— Air V ent, 1 / 8 -in. MPT 10 — Retu rn Conn, 5 / 8 -in. OD ...

  • Carrier 42S - page 6

    6 NO TES: 1. Right hand unit with standard 3-ro w coil shown; left hand unit opposite. Coil connection locations are ± 5 / 8 -in. 2. Unit sizes 02 and 03 hav e one motor , one b lower; sizes 04 through 08 have one motor , 2 bl owers; siz es 10 and 12 hav e 2 motors, 4 b low ers. 3. Standard 3-row coil sho wn. 4. Unit av ailab le with bottom or rea ...

  • Carrier 42S - page 7

    7 NO TES: 1. Right h and unit with standard 3-row coil shown; left hand unit opposite. Coil connection locations are ± 5 / 8 -in. 2. Unit sizes 02 and 0 3 hav e one motor , one b lower; sizes 04 through 08 have one motor , 2 blo wers; siz es 10 and 12 hav e 2 motors, 4 b lowers . 3. Standard 3-row coil shown. 4. Unit availab le with bottom or rear ...

  • Carrier 42S - page 8

    8 LEGEND 1— Junction Bo x, Installed with Plenum 2— Flexible Metal Conduit 3— Insulated Plenum 4— Mounting Brack et 5— Drain Conn, 7 / 8 -in. OD 6— T ell-T ale Drain Conn, 5 / 8 -in. OD (optional) 7— Drip Lip (optional, shipped lo ose) 8— Filter 9— Return Duct Collar, 1-in. 10 — Access Panel 11 — Supply Du ct Collar , 1-in. 12 ...

  • Carrier 42S - page 9

    9 LEGEND 1— Junction Bo x, Installed with Plenum 2— Plenum 3— Flexib le Metal Conduit 4— Mounting Brack et 5— Electric Str ip Heater Element 6— Drain Conn, 7 / 8 -in. OD 7— Drip Lip (optional, shipped loose) 8— T ell-T ale D rain Conn, 5 / 8 -in. OD (optional) 9— Filter 10 — Retu rn Duct C ollar , 1-in. 11 — Air V ent, 1 / 8 - ...

  • Carrier 42S - page 10

    10 LEGEND 1— Junction Bo x, 4 in. x 4 in. 2— Optional Retur n Air Location 3— Optional Drip L ip , shipped loose 4— Mounting Holes (4), Rubber Grommets hav e 3 / 8 -in. Diameter Hole 5— Electrical KO , 7 / 8 -in. Diameter 6— Return KO , 1-in. Diameter 7— Supply K O , 1 1 / 2 -in. Diameter 8— Drain K O, 1 1 / 2 -in. Diameter 9— Sup ...

  • Carrier 42S - page 11

    11 LEGEND 1— Junction Bo x, 4 in. x 4 in. 2— Optional Stamped Rear Retur n Gr ille 3— Optional Drip L ip , shipped loose 4— Electric Strip Heater Element 5— Mounting Holes (4), Rubber Grommets hav e 3 / 8 -in. Diameter Hole 6— Electrical KO , 7 / 8 -in. Diameter 7— Return KO , 1-in. Diameter 8— Supply K O , 1 1 / 2 -in. Diameter 9? ...

  • Carrier 42S - page 12

    12 UNIT SIZE NOM AIRFLO W (Cfm) DIMENSIONS (in.) QTY/UNIT BO TT OM RETURN FIL TER SIZE, (in.) ABCDE F B l o w e r M o t o r 02 200 3 5 16 12 3 / 4 37 32 6 1 1 10 x 28 03 300 3 5 20 8 3 / 4 37 32 6 1 1 10 x 28 04 400 4 1 26 8 3 / 4 43 38 6 2 1 10 x 33 06 600 5 3 31 15 3 / 4 55 50 7 2 1 10 x 45 08 800 53 38 8 3 / 4 55 50 7 2 1 10 x 45 10 1000 75 52 1 ...

  • Carrier 42S - page 13

    13 NO TES: 1. Right hand unit shown; left hand unit opposite. 2. Internal factory valv e package and dr ains ma y not align with cabinet knockouts. 3. Dimensions shown in inches (mm). All dimensions are ± 1 / 4 in. 4. Bottom panel is Arctic White polyester po wder coat paint. UNIT SIZE NOM AIRFLO W (Cfm) DIMENSI ONS (i n.) QTY/U NIT BOTT OM RETU R ...

  • Carrier 42S - page 14

    14 NO TES: 1. Right hand unit shown; left hand unit opposite. 2. Internal factor y valv e pac kage and drains may not align with cabinet knockouts . 3. Dimensions shown in inches (mm). All dim ensions are ± 1 / 4 in. 4. Bottom panel is Arctic White polyester powder coat paint. UNIT SIZE NOM AIRFLO W (Cfm) DIMENSIONS (in.) QTY/UNIT REAR RETURN FIL ...

  • Carrier 42S - page 15

    15 NO TES: 1. Right hand unit shown; left hand unit opposite. 2. Internal factory valve pac kage and drains ma y not align with cabinet knockouts . 3. Dimensions shown in inches (mm). All dimensions are ± 1 / 4 in. 4. Bottom panel is Arctic White polyester powder coat paint. UNIT SIZE NOM AIRFLO W (Cfm) DIMENSIONS (in.) QTY/UNIT REAR RETURN FIL TE ...

  • Carrier 42S - page 16

    16 LEGEND 1— Junction Bo x, 4 in. x 4 in. 2— Optional Drip Lip, shipped loose 3— Mounting Holes (4), Rubber Grommets hav e 3 / 8 -i n. Diam eter H ole 4— Piping K O , 1 1 / 2 -in. Diameter 5— Electrical KO , 7 / 8 -in. Diameter 6— Drain K O, 1 1 / 2 -in. Diameter 7— Supply Duct Collar 8— Return C onnection, 5 / 8 -in. OD . 9— Opti ...

  • Carrier 42S - page 17

    17 LEGEND 1— Junction Bo x, 4 in. x 4 in. 2— Strip Heater High Limit 3— Electric Str ip Heater Element 4— Optional Drip Lip, shipped loose 5— Mounting Holes (4), Rubber Grommets hav e 3 / 8 -in. Diameter Hole 6— Piping K O , 1 1 / 2 -in. Diameter 7— Electrical K O , 7 / 8 -in. Diameter 8— Drain K O , 1 1 / 2 -in. Diameter 9— Suppl ...

  • Carrier 42S - page 18

    18 LEGEND 1— Optional Unit Mounted Control Box 2— W all Mounting Holes (4), 3 / 4 -in. Diameter 3— Drain, 3 / 4 -in. MPT 4— Drain P an, A uxiliary , Shipped Loose 5— Supply Conn, 5 / 8 -in. OD 6— Return Con n, 5 / 8 -in. OD 7— Filter 8— Air V ent, 1 / 8 -in. MPT 9— Disch arge O peni ng 10 — Flexible Conduit 11 — Front Access P ...

  • Carrier 42S - page 19

    19 LEGEND 1— Standard Stamped Supply Grille 2— Access Door , F an Switch 3— Supply Conn, 5 / 8 -in. OD 4— Return Co nn, 5 / 8 -in. OD 5— Drain, 3 / 4 -in. MPT 6— Filter 7— Air V ent, 1 / 8 -in. MPT 8— F ront P anel F astener 9— Drain P an, A uxiliary , Shipped Loose 10 — Wall Mounting Holes (4), 3 / 4 -in. Diameter 11 — Flexib ...

  • Carrier 42S - page 20

    20 LEGEND 1— Standard Stamped Supply Grille 2— Access Door , F an Switch 3— Supply Conn, 5 / 8 -in. OD 4— Return Conn , 5 / 8 -in. OD 5— Drain, 3 / 4 -in. MPT 6— Filter 7— Air V ent, 1 / 8 -in. MPT 8— F ront P anel F astener 9— Optional V alv e P ac kage (inside cabinet) 10 — Drain Pan, A uxiliary , Shipped Loose 11 — Wall Mou ...

  • Carrier 42S - page 21

    21 LEGEND 1— Optional Unit Mounted Control Box 2— Drain P an, A uxiliary , Shipped Loose 3— Supply Conn, 5 / 8 -in. OD 4— Drain, 3 / 4 -i n. MPT 5— Return Con n, 5 / 8 -in. OD 6— Air V ent, 1 / 8 -in. MPT 7— Discharge Opening 8— Filter *Unit weights are based on dry coils and minimum ro ws . W eights e xclude packaging, v alv es, an ...

  • Carrier 42S - page 22

    22 LEGEND 1— Unit-Mounted Control Box (Optional) 2— Drain P an, A uxiliary , Shipped Loose 3— Air V ent, 1 / 8 -in. MPT 4— Supply Conn, 5 / 8 -in. OD 5— Drain, 3 / 4 -in. MPT 6— Return Conn, 5 / 8 -in. OD 7— Filter 8— Electrical Sheath Heater Element 9— Discharge Opening *Unit weights are based on dr y coils and minimum ro ws . We ...

  • Carrier 42S - page 23

    23 *Unit weights are based on dry coils and minimum ro ws . W eights e xclude packaging, v alv es, and other components . UNIT SIZE NOM AIRFLO W (Cfm) DIMENSI ONS (i n.) QTY/UNI T F A CE AR EA (sq ft) UNIT WEIGHT* (lb) ABDC Blower Motor 02 200 41 22 3 3 / 4 17 2 1 1.18 72 03 300 46 27 42 1 1 / 2 2 1 1.53 100 04 400 54 35 3 5 / 8 30 1 / 4 2 1 2.08 1 ...

  • Carrier 42S - page 24

    24 *Unit weights are based on dry coils and minimum ro ws . W eights e xclude packaging, v alv es, and other components . UNIT SIZE NOM AIRFLO W (Cfm) DIMENSIONS (in.) QTY/UNIT F A CE AREA (sq ft) UNIT WEIGHT* (lb) ABCD Blower Motor 02 200 41 22 3 3 / 4 17 2 1 1.18 7 2 03 300 46 27 4 21 1 / 2 2 1 1.53 100 04 400 54 35 3 5 / 8 30 1 / 4 2 1 2.08 108 ...

  • Carrier 42S - page 25

    25 LEGEND 1— Supply Conn, 5 / 8 -in. OD 2— Air V ent, 1 / 8 -in. MPT 3— Filter 4— Retur n Air Grille, Stamped 5— Stamped Supply Grille 6— Retur n Conn, 5 / 8 -in. OD 7— Remov able F ront Panel 8— Drain Conn, 7 / 8 -in. O D 9— Auxiliary Drain P an 10 — V alve Compartment 11 — Junction Box NO TES: 1. Right hand unit shown; left ...

  • Carrier 42S - page 26

    26 *Unit weight s are based on dry coils and minimum ro ws. W eights e xclude pac kaging, v alv es , and other components . NO TES: 1. Right hand unit sho wn; left hand unit opposite . Coil connect ion locations are ± 5 / 8 inches . 2. Sizes 06, 08 and 10 ha v e one motor , one b low er; sizes 12 through 20 ha v e 2 motors, 2 b low ers. 3. Standar ...

  • Carrier 42S - page 27

    27 *Unit weights ar e based on dry coils and minimum r ows. Wei ghts e xclude packag ing, v alves , and other components. NO TES: 1. Right hand unit shown; lef t hand unit opposit e. Coil conne ction locatio ns are ± 5 / 8 inches. 2. Sizes 06, 08 and 10 ha v e one motor , one blower . Sizes 12 through 20 ha ve 2 motors, 2 b lower s. 3. Filter and ...

  • Carrier 42S - page 28

    28 *Unit weights are b ased on dry coils and minimum ro ws. W eights e xclude pac kaging, v alv es, and o ther components. NO TES: 1. Right hand unit shown; l eft hand unit op posite. Coil connection lo cations are ± 5 / 8 inches . 2. Standard 4-ro w coil shown. Other coil opt ion dimensional data a vai labl e on request. 3. Sizes 06, 08 and 10 ha ...

  • Carrier 42S - page 29

    29 *Unit weight s are based on dry coils and minimum rows . Wei ghts e xclude pac kaging, v alv es, and other components. NO TES: 1. Right hand unit sho wn; left hand unit opposite . 2. Coil stub-out location dat a av ailab le on request. 3. Unit fab ricated of galvaniz ed steel. 4. Internal par ts f abricated of galvaniz ed steel. 5. Sizes 06, 08 ...

  • Carrier 42S - page 30

    30 *Unit weights a re based on dry coils and minimum r ows . Wei ghts e xclude packag ing, v alv es, and other components. NO TES: 1. Right hand unit sho wn; left hand unit opposit e. 2. Coil stub-out connection data av ailab le on req uest. 3. Units f abricated of galv aniz ed steel with a n Arctic White bak ed fini sh. 4. Inter nal pa r ts f abr ...

  • Carrier 42S - page 31

    31 *Drawing provided for reference only . Dime nsions may vary with op tions ordered. NOTES: 1. Units are f abricated o f 18-gage ga lvan ized ste el with a 16- gage galv aniz ed f an dec k. 2. All risers are insulated w ith 1 / 2 -in. closed cell insulation. 3. Thermostats shipped loose fo r field connecti on. 4. Risers are pipe d to coil with val ...

  • Carrier 42S - page 32

    32 †Unit we ights are base d on dry coils and min imum ro ws. W eigh ts e xclude pac kaging, v alv es, and other co mponents . UNIT SIZE NOM AIRFLO W (cfm) DIMENSION S (in.) UNIT WEIGHT† (lb) Single Supply Double Supply CDE F G ABAB 03 300 14 8 14 6 17 2 2 3 / 8 1 1 / 2 22 1 / 8 14 3 / 4 202 04 400 14 12 14 8 17 22 3 / 8 1 1 / 2 22 1 / 8 14 3 / ...

  • Carrier 42S - page 33

    33 †Unit we ights are base d on dry coils and min imum ro ws. W eigh ts e xclude pac kaging, v alv es, and other co mponents . UNIT SIZE NOM AIRFLO W (cfm) DIMENSIONS (in.) UNIT WEIGHT† (lb) Single Supply Double Supply T op Suppl y EG H I J AB A BC D 03 300 14 8 14 6 14 10 17 1 1 / 2 1 1 / 2 14 40 1 / 4 360 04 400 14 12 14 6 14 10 17 1 1 / 2 1 ...

  • Carrier 42S - page 34

    34 *Dra wing prov ided f or re fer ence only . Dimensions ma y v ary with options ordered. NO TES: 1. Units are f abricated of 18-gage galva nized steel with a 16-gage g alvani zed f an de ck. 2. All risers ar e insulated with 1 / 2 -in. closed cell insulation. 3. Thermostats shipped loose f or field connection. 4. Risers are pipe d to coil with va ...

  • Carrier 42S - page 35

    35 *Draw ing provi ded fo r refe rence only . Dimensions may v ary with options ord ered. NOTES: 1. Units are fabrica ted of 18-gag e galv aniz ed steel with a 16-gage ga lvan ized f an d eck. 2. All risers are insulated with 1 / 2 -in. closed cell insulation. 3. Ther mostats shipped loose f or field conn ection. 4. Risers are piped to coil wit h v ...

  • Carrier 42S - page 36

    36 Fig. 33 — 42SU Universal Furr ed-In Stac k Dimensions *Unit weigh ts are based on dry coils and minimum ro ws. W eig hts excl ude pack aging, v alv es, and o ther components . UNIT SIZE UNIT WEIGHT* lb (kg) DIMENSIONS, in. (mm) FIL TER SIZE in. (mm) Side Supply T op Supply AB S i z e CD S i z e E FH I 03 360 (163) 14 (356) 12 (305) 14 x 12 (35 ...

  • Carrier 42S - page 37

    37 Fig. 34 — 42SU Universal Furred- In St ack with Hea ter Dimensions *Unit weights are based on dry coils and minimum rows. W eights e xclude pac kaging, v alv es, and other components. UNIT SIZE UNIT WEIGHT* lb (kg) DIMENSIONS, in. (mm ) FIL TER SIZE in. (mm) Side Supply T op Sup ply AB S i z e CD S i z e E FH I 03 360 (163) 14 (356) 12 (305) 1 ...

  • Carrier 42S - page 38

    38 Fig. 35 — Return-A ir W all P anel s for Furred-In Units — P anels wit h No Frame PANEL DIMENSIONS (in.) NO TE: Dimensions in inches. P ANEL NO. UNIT SIZE A 1 03, 04 15.5 06, 08 19.5 10, 12 23.5 2 03, 04 15.5 06, 08 19.5 10, 12 23.5 3 03, 04 15.2 06, 08 19.2 10, 12 23.2 6 03, 04 15.5 06, 08 19.5 10, 12 23.5 7 03, 04 15.1 06, 08 19.1 10, 12 2 ...

  • Carrier 42S - page 39

    39 Fig. 36 — Return-Air W all P anels for Furred-In Units — P anels with Frame PANEL AND FRAME DIMENSIONS (in.) NO TE: Dimensions in inches. P AN EL NO . UNIT SIZE A 4 03, 0 4 15.1 06, 0 8 19.1 10, 1 2 23.1 5 03, 0 4 15.1 06, 0 8 19.1 10, 1 2 23.1 9 03, 04 15.1 06, 08 19.1 10, 12 23.1 PANEL NO. 4 54.7 A A42-4168 PANEL NO. 5 60.4 A A42-4170 PANE ...

  • Carrier 42S - page 40

    40 INST ALLA TION Step 1 — Place Units in P osition 42C UNITS 1. Select the unit location. Allow adequate space for free air circulation, service clearances, piping and electrical connections, and any necess ary ductwork. For specific unit dimensions, refer to Fig. 1-14. Allow clearances ac- cording to local and national electric codes. 2. Make s ...

  • Carrier 42S - page 41

    41 42 S UNI TS — A factory tag is on top of each unit. T a g states riser tier number , floor , room number if furnished and supply- air arrangement. Check unit for a ny other labels that apply to installation. Remove unit from pallet and take directly to assigned space for installation. Great care must be taken to assure that no force or pressur ...

  • Carrier 42S - page 42

    42 h. After all drywalling and paint ing is complete, install thermostats, supply air grilles an d return air panels. 7. Attach unit risers: NOTE: The supply and return connections are marked on the coil stub-outs and the valve package with an “S” meaning supply or inlet and “R ” meaning return or outlet indicating flow direction to and fro ...

  • Carrier 42S - page 43

    43 V ALVE PAC KAGES — T he r e are limitations on physical size of pneumatic valves, qua ntity and type of matching components, and required cont rol interface. See Fig. 43. Consult factory before orderi ng any special valve package components that are not covered in this book. V alve packages are shipped with the units or in unit cartons. V alve ...

  • Carrier 42S - page 44

    44 Fig. 42 — Piping Connection Positions Hydr onic Co il Arrangement Field Piping Connect ions* VERTICAL FLOOR UNITS — 42VB, VE, VF Pipe into cabinet end co mpar tment (opening i n bottom and back ). VERTICAL FLOOR UNITS — 42V A, VC Pipe to external connections (no cabinet). CEILING UNITS (EXPOSED) — 42CG, CK, DE, DF Pipe through kn ock-out ...

  • Carrier 42S - page 45

    45 Fig. 43 — Symbols and Placemen t of Valves Coil Connections (P ositions A & B) — When isolation valve only is added to supply or retur n line, the isolation valv e will be factory brazed to the coil stub-out. A ddition of any other component or connection to the supply or retur n line will change the respectiv e coil connection(s). Servi ...

  • Carrier 42S - page 46

    46 BALL V AL VE GA TE SHUT OFF (1) GA TE (1) BALL (1) 2-W A Y MOTORIZED R S COIL BALL V AL VE BALL V AL VE (2) BALL (1) BALANCING (1) 2-W A Y MOTORIZED R S COIL CIRCUIT SETTER BALL V AL VE (1) BALL (1) CIRCUIT SETTER (1) 2-W A Y MOTORIZED R S COIL MOTORIZED 2-W A Y V AL VE A BYP ASS BALANCING VA LV E A MOTORIZED 2-W A Y V AL VE BYP ASS A MOTORIZED ...

  • Carrier 42S - page 47

    47 CIRCUIT SETTER (1) BALL (1) CIRCUIT SETTER (1) 3-W A Y MOTORIZED COIL BALL V AL VE GA TE SHUT OFF V AL VE (1) GA TE (1) BALL (1) 3-W A Y MOTORIZED R S COIL BALL V AL VE BALL V AL VE (2) BALL (1) BALANCING (1) 3-W A Y MOTORIZED R S COIL MOTORIZED 3-W A Y V AL VE BYP ASS BALANCING VA LV E MOTORIZED 3-W A Y V AL VE BYP ASS (1) BALL (1) 3-W A Y MOTO ...

  • Carrier 42S - page 48

    48 WITH HAND V AL VES ONL Y BALL V AL VE BALL V AL VE (2) BALL R S COIL BALL V AL VE GA TE SHUT OFF V AL VE (1) BALL (1) GA TE R S COIL BALL V AL VE BALL V AL VE (2) BALL (1) BALANCING R S COIL BALL V AL VE (1) BALL (1) CIRCUIT SETTER R S COIL BALL V AL VE BALL V AL VE (2) BALL (1) 2-W A Y MOTORIZED R S COIL BALL V AL VE (WITH MEMOR Y ST OP) BALL V ...

  • Carrier 42S - page 49

    49 42 C, D ,V D RA IN C ON NE C TI ON S — Install drain line in accordance with all applicable codes. A continuous pitch of 1 in. per 10 ft of condensate dr ain line run is necessary for adequate condensate drainage. Insulate the drain line to prevent sweating. Extend the drain line straight from the drain pan before making any turns. The install ...

  • Carrier 42S - page 50

    50 Table 5 — Piping Components LEGEND *Check all system component pres sure ratings (coils , values , pumps, etc.) with manuf acturer and any applicable local or national piping codes prior to specifying system pressure rating. NO TES: 1. Motorized 2-wa y valv es hav e a maximum close-off diff erential of 25 psi. 2. Motorized 3-wa y valv es hav e ...

  • Carrier 42S - page 51

    51 Table 5 — Piping Components (cont) LEGEND *Check all system component pres sure ratings (coils , values , pumps, etc.) with manuf acturer and any applicable local or national piping codes prior to specifying system pressure rating. NO TES: 1. Motorized 2-wa y valv es hav e a maximum close-off diff erential of 25 psi. 2. Motorized 3-wa y valv e ...

  • Carrier 42S - page 52

    52 Table 5 — Piping Components (cont) LEGEND *Check all system component pres sure ratings (coils , values , pumps, etc.) with manuf acturer and any applicable local or national piping codes prior to specifying system pressure rating. NO TES: 1. Motorized 2-wa y valv es hav e a maximum close-off diff erential of 25 psi. 2. Motorized 3-wa y valv e ...

  • Carrier 42S - page 53

    53 Table 5 — Piping Components (cont) LEGEND *Check all system component pres sure ratings (coils , values , pumps, etc.) with manuf acturer and any applicable local or national piping codes prior to specifying system pressure rating. NO TES: 1. Motorized 2-wa y valv es hav e a maximum close-off diff erential of 25 psi. 2. Motorized 3-wa y valv e ...

  • Carrier 42S - page 54

    54 Fig. 49 — Copper Water Tube and Join t Material Pressu re Ratings NO TES: 1. Not recommended for high system w ater pressures. 2. Standard f actory joint mater ial. JOINT MA TERIALS A 50-50 Lead-Tin at 200 F Note 1 D 95-5 Tin-Antimony at 200 F Note 2 B 50-50 Lead-Tin at 150 F E 95-5 Tin-Antimony at 150 F C 50-50 Lead-Tin at 100 F F 95-5 T in-A ...

  • Carrier 42S - page 55

    55 Step 3 — Make Electrical Connection s — Refer to unit nameplate for required supply voltage, fan and heater amperage and required circuit ampacity . Refer to unit wire dia- gram for unit and field wiring. Make sure all electrical connec- tions are in accordance with unit wiring diagram and all appli- cable codes. The fan motor(s) should neve ...

  • Carrier 42S - page 56

    56 T hermostatic F an C ontro l , 2-P ipe S ystems — The thermo- stat cycles the fan on and of f from any sel ected speed setting to maintain selected room temperat ure. Controls can be wired for heating-only , cooling-only or for heating/cooling by the addi- tion of an automatic changeover device that senses water tem- perature and changes the a ...

  • Carrier 42S - page 57

    57 Fig. 53 — 42SG,SH,SJ,VA,VB,VC,VE,VF 2-Pipe Heating and Cooling with Automatic Changeover — Unit-Mounted Ther mostat (Line Voltage) a42-4060 120-V WHT ALL O THERS BLK  NEC CLASS 1 WIRING UNIT MOUNTED J BOX EQUIPMENT GROUND L2 or N L1 THERMOST A T P ART # 702893-36 MED W/RED HI W/ORG L1 BLK LOW W/BRN HEA T RED COOL BLU PUR ORG L2 OR N YEL V ...

  • Carrier 42S - page 58

    58 Fig. 55 — 42SG,SH,SJ,VA,VB,VF 2-Pipe Heatin g and Cooling with Automatic Changeover — Unit-Mounted Debona ir ® Thermostat (2 4-v), Duct Sensor a42-4059 Fig. 56 — 42C,S,V (ex cept VG), and 42D (600- 1000 cfm) 2-Pipe Heat ing and Cooling wit h Automatic Change over — Remote/Wall-Moun ted Debonair ® Thermostat (24-v) a42-4061 NEC CLASS 2 ...

  • Carrier 42S - page 59

    59 T hermostatic 2-P ipe A uxiliary E lectric H eat with V alve C ontrol — This system, also called twilight or intermediate season electric heat, goes a long way towards solving the spring and fall control problems of 2-pipe systems. Chilled water can be run late into the fall, turned on early in the spring and heat will still be available to al ...

  • Carrier 42S - page 60

    60 Fig. 58 — 42C,S,V (exc ept VG), and 42D (600-100 0 cfm) 2-Pipe Heating and Cooling with Auxiliary Heat — Remote/Wall-Mount ed Thermostat (Line Voltage ) and Dual Power Source UNIT MOUNTED J BOX EQUIPMENT GROUND L2 or N L1 THERMOST A T P ART # 702893-36 W/RED HI W/ORG L1 BLK LOW W/BRN HEA T RED COOL BLU PUR ORG L2 OR N YEL VA LV E REMOTE DEVI ...

  • Carrier 42S - page 61

    61 T hermostat 2-P ipe T otal E le ctric H eat with V alve C on- trol — W ith this system, the complete heating requirement for the space is provided by the electric heater; the water system is never changed over for heating. It is therefore poss ible, just as with 4-pipe systems, to have heating or cooling at any time of the year . The fan runs ...

  • Carrier 42S - page 62

    62 Fig. 61 — 42SG,SH,SJ,VA,VB,VC,VE,VF 2-Pi pe Cooling with Total Electric Heat — Unit-Mounted Thermos tat (Line Voltag e) a42-4073 120-V WHT ALL O THE RS BLK  NEC CLASS 1 WIRING Fig. 62 — 42C,S,V (ex cept VG), and 42D (600- 1000 cfm) 2-Pipe Cooli ng with Total Ele ctric Heat — Remote/Wall-Mounted Thermostat (Line Voltage) ...

  • Carrier 42S - page 63

    63 Fig. 63 — 42SG,SH,SJ,VA,VB ,VC,VE,VF 2-Pipe Cooling with Tota l Electric Heat — Unit-Mounted Debona ir ® Thermosta t (24-v) and Duct Sensor a42-4072 NOTE: Units may ha ve 2 or 4 elements. Elements wired in parallel. Fig. 64 — 42C,S,V (except VG) , and 42D (600-1 000 cfm) 2-Pipe Cooling wi th Total Electri c Heat — Remote/Wall-Mounted De ...

  • Carrier 42S - page 64

    64 T hermostatic V alve C on trol , 4-P ipe — The 4-pipe system provides the ultimate in economy and room temperature con- trol. Both hot water and chilled water are available at any tim e. Normally an automatic changeover thermostat is used, but a manual changeover thermostat is also suitable. T wo 2-way valves, two 3-way valves, or one 2-way pl ...

  • Carrier 42S - page 65

    65 Fig. 66 — 42C,S,V (exce pt VG), and 42D (600 -1000 cfm) 4-Pipe Heating and Cooling — Remote/Wall-Mounted Thermostat (Line Volt age) ONL Y 120V WHT/ALL OTHERS BLK Fig. 67 — 42SG,SH,SJ,VA,VB,VC,VE, VF 4-Pipe Heating and Cooling — Unit-Mounted Debonair ® Thermosta t (24-v) a nd Duct Senso r a42-4078 ...

  • Carrier 42S - page 66

    66 Step 4 — Make Duct Connections — Install all ductwork to and from unit in accordance with all applicable codes. Duct construction must a llow unit to operate within duct external static pressure limits as shown on job submittals. Units designed to operate with ductwor k may be damaged if operated without intended ductwork attached. Units pro ...

  • Carrier 42S - page 67

    67 Step 6 — Cut out Openings f or Grilles and Thermostats — On all units with optional supply-air or return-air grilles, dampers, thermostats, and switch plates, cut out openings where specified on the job plans. Be careful not to cut wires, piping or structural supports. For remote-mounted thermostats use a steel thermostat shield ring to prot ...

  • Carrier 42S - page 68

    68 Standard motors are permanently sealed and lubricated. No lubrication is required unles s special motors have been supplied or unusual operating conditions exist. Clean Fa n Wheel — Lock open and tag unit electrical service switch. For access to fan assembly , remove front or bottom panel. Fan assembly may be removed from its tracks if unit ha ...

  • Carrier 42S - page 69

    69 ...

  • Carrier 42S - page 70

    Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No . 04-53 420004-01 Printed in U .S .A. Fo rm 42-3SI Pg 70 12-09 Replaces: 42-2SI Copy right 2009 Carrier Cor poration ...

  • Carrier 42S - page 71

    CL-1 ST ART -UP CHECKLIST FOR 42C,D,S,V SERIES F AN COIL AIR CONDITIONERS I. Pr oject Inf ormation Job Name _________ _____________________ __________________ ____________________ ___ Address __________ _____________________ __________________ ____________________ ___ City ___________ _________________ __________________ Sta te __ _ __ __ __ _ Zip ...

  • Carrier 42S - page 72

    Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No . 04-53420004-0 1 Printed in U .S.A. F orm 42-3SI CL-2 12-09 Replaces: 42-2SI Copy right 2009 Carrier Cor poration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ...

Manufacturer Carrier Category Air Conditioner

Documents that we receive from a manufacturer of a Carrier 42S can be divided into several groups. They are, among others:
- Carrier technical drawings
- 42S manuals
- Carrier product data sheets
- information booklets
- or energy labels Carrier 42S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Carrier 42S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Carrier 42S, service manual, brief instructions and user manuals Carrier 42S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Carrier 42S.

Similar manuals

A complete manual for the device Carrier 42S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Carrier 42S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Carrier 42S.

A complete Carrier manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Carrier 42S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Carrier 42S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Carrier 42S, that we can find in the current document
3. Tips how to use the basic functions of the device Carrier 42S - which should help us in our first steps of using Carrier 42S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Carrier 42S