  • APC SMX3000RMHV2U - page 1

    Operation Manual Smart-UPS ® X Uninterruptible Power Supply Low V olt age (100-127 V) SMX2000RML V2U SMX2200RML V2U SMX3000RML V2U SMX3000RML V2UNC SMX3000RMJ2U High V olt age (200-240 V) SMX2200RMHV2U SMX3000RMHV2U SMX3000RMHV2UNC ...

  • APC SMX3000RMHV2U - page 2

    ...

  • APC SMX3000RMHV2U - page 3

    1 Smart-UPS X 2000/2200/3000 VA Overview About the UPS The APC ® by Schneider Electric Smart-UPS ® X is a high performa nce un interruptible power supply (UPS). It provides protection for electronic equipm ent from utility power black outs, brownouts, sags, and surges; small utility fluctuations and large dist urbances. The UPS also provides batt ...

  • APC SMX3000RMHV2U - page 4

    Smart-UPS X 2000/2 200 /3000 VA 2 Rear p anel S pecifications Operating Conditions This unit is intended for indoor use only . Select a location sturdy enough to supp ort the weight of the UPS and XLBP. Do not operate the unit where there is excessive dust, or the temperature or humidity are outside the specified limits. This unit has front and r e ...

  • APC SMX3000RMHV2U - page 5

    3 Smart-UPS X 2000/2200/3000 VA Inst allation UPS For UPS installation information, see the Smar t-UPS X 2000-3000 V A Quick-Start that is included with the UPS. The guide is also ava ilable on the enclosed CD and the APC W eb site at www .apc.com . Network Management Card For installation information, see the user ma nual provided with the Network ...

  • APC SMX3000RMHV2U - page 6

    Smart-UPS X 2000/2 200 /3000 VA 4 Operation Connect Equipment to the UPS Note: The UPS will charge to 90% capacity in th e first three hours of normal operation. Do not expect full battery runtime capability during this initial charge period. 1. Connect equipment to the outlets on the rear panel of the UPS . 2. Connect the UPS to th e building util ...

  • APC SMX3000RMHV2U - page 7

    5 Smart-UPS X 2000/2200/3000 VA Display Interface Overview Using the display interface Use the U P and D OWN buttons to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. Menu Overview The Smart-UPS has Standard and Ad vanced menu screens ...

  • APC SMX3000RMHV2U - page 8

    Smart-UPS X 2000/2 200 /3000 VA 6 Load (A) x Load meter (kWh) x Last transfer to battery power information x x Battery charge and estimated run time x x Battery volta ge x Number of external battery packs x Internal battery temperature x Run time calibration test results x x Self-test results x x Status of the switched outlet group(s): On, Off, Sle ...

  • APC SMX3000RMHV2U - page 9

    7 Smart-UPS X 2000/2200/3000 VA About General information about the UPS, including: model num bers, output voltage setting, serial numb er , manufacture date, replacement battery cartr idge information, firmware versions, and suggest ed batt ery replacement date. xx SmartSlot card information (i f applicable), including IP address x PowerChute Busi ...

  • APC SMX3000RMHV2U - page 10

    Smart-UPS X 2000/2 200 /3000 VA 8 Configuration UPS Settings St art-up Settings Use the display interface to configure these settings at initial start -up. The UPS will prompt for a response to each setting, if no response is given, the default setting will be used. Note: The unit will not turn on until all of these settings are entered. Function F ...

  • APC SMX3000RMHV2U - page 11

    9 Smart-UPS X 2000/2200/3000 VA General Settings Configure these settings at any time, usin g the display interface, APC PowerChute ® software, or a network management card. Function Factory Defaul t Options Description High T ransfer Point Low V oltage T o avoid unnecessary battery usage, set the transfer point higher if the utility vo ltage is c ...

  • APC SMX3000RMHV2U - page 12

    Smart-UPS X 2000/2 200 /3000 VA 10 Audible Alarm On On/Off The UPS will neve r beep if all audible alarms are set to Off or wh en th e di splay buttons are pressed. Auto Self-T est Interval Setting On start-up and every 14 days since the last test • Last test + 14 days • Last test + 7 days • T urn on + 14 days • T urn on + 7 days • On sta ...

  • APC SMX3000RMHV2U - page 13

    11 Smart-UPS X 2000/2200/3000 VA Switched Outlet Group s Overview The Switched Outlet Groups can be conf igured to independently turn of f, turn on, shut down, put to sleep, and reboot conn ected equipment. The Switched Outlet Groups can be commanded to do the following: • T urn off: Disconnect from power immediatel y and restart only with a manu ...

  • APC SMX3000RMHV2U - page 14

    Smart-UPS X 2000/2 200 /3000 VA 12 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC). • NMC IP Address Mode • NMC Default Gateway T urn Off Delay 90 sec Set the value in seconds The amount of time that the Switched Outlet Groups will wait between receiving the command to turn o ...

  • APC SMX3000RMHV2U - page 15

    13 Smart-UPS X 2000/2200/3000 VA Emergency Power Off EPO Overview The Emergency Power Of f (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . Connect each UPS to the EPO switch. The UPS must be manually restarted t ...

  • APC SMX3000RMHV2U - page 16

    Smart-UPS X 2000/2 200 /3000 VA 14 T roubleshooting Problem and P ossible Cause Solution The UPS will not turn on or ther e is no output The unit has not been turned on. Press the ON button to tu rn on the UPS. The UPS is not connected to utility power . Ensure that the power cable is securely connected to the unit and to the utility power supply . ...

  • APC SMX3000RMHV2U - page 17

    15 Smart-UPS X 2000/2200/3000 VA Service and Support Service If the unit requires service, do not re turn it to the dealer . Follow these steps: 1. Review the T r oubleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Sup port through the APC W eb site, www .apc .com . a. Note the model n ...

  • APC SMX3000RMHV2U - page 18

    Smart-UPS X 2000/2 200 /3000 VA 16 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date of purchase. APC's obligation under ...

  • APC SMX3000RMHV2U - page 19

    ...

  • APC SMX3000RMHV2U - page 20

    09/201 1 990-3651C APC W orldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • V isit the APC W eb site to acce ss documents in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb si ...

Manufacturer APC Category Power Supply

Documents that we receive from a manufacturer of a APC SMX3000RMHV2U can be divided into several groups. They are, among others:
- APC technical drawings
- SMX3000RMHV2U manuals
- APC product data sheets
- information booklets
- or energy labels APC SMX3000RMHV2U
All of them are important, but the most important information from the point of view of use of the device are in the user manual APC SMX3000RMHV2U.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals APC SMX3000RMHV2U, service manual, brief instructions and user manuals APC SMX3000RMHV2U. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product APC SMX3000RMHV2U.

Similar manuals

A complete manual for the device APC SMX3000RMHV2U, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use APC SMX3000RMHV2U by users. Manuals are usually written by a technical writer, but in a language understandable to all users of APC SMX3000RMHV2U.

A complete APC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual APC SMX3000RMHV2U - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the APC SMX3000RMHV2U, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the APC SMX3000RMHV2U, that we can find in the current document
3. Tips how to use the basic functions of the device APC SMX3000RMHV2U - which should help us in our first steps of using APC SMX3000RMHV2U
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with APC SMX3000RMHV2U
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of APC SMX3000RMHV2U in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning APC SMX3000RMHV2U?

Use the form below

If you did not solve your problem by using a manual APC SMX3000RMHV2U, ask a question using the form below. If a user had a similar problem with APC SMX3000RMHV2U it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)