  • Vermont Casting 410 - page 1

    Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN ...

  • Vermont Casting 410 - page 2

    2 Madison Woodburning Stove 30001453 Introduction Thank you for choosing a Vermont Castings Madison to meet your heating needs. We're confident you will find the Madison to be an effective woodburning heater incorporating modern, non-catalytic combustion technology with the classic aesthetic appeal of its Vermont Castings lineage. The Madison ...

  • Vermont Casting 410 - page 3

    3 Madison Woodburning Stove 30001453 Specifications Madison, Model 1655 Series Range of Heat Output ............... 1 1,300 - 39,700 BTU’ s Maximum heat output ......................... 39,700 Btu’s/hr . 1 Area heated ..................................... Up to 1600 sq. ft. 2, EP A emissions ratings, g/h, non-catalytic .............. 3.3 3 Fuel ...

  • Vermont Casting 410 - page 4

    4 Madison Woodburning Stove 30001453 Chimneys Y our stove must be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney . Whichever of those types you use, the chimney and chimney con- nector must be in good condition and kept clean. If ...

  • Vermont Casting 410 - page 5

    5 Madison Woodburning Stove 30001453 Masonry Chimneys, cont'd. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the eve ...

  • Vermont Casting 410 - page 6

    6 Madison Woodburning Stove 30001453 Double-wall Chimney Connectors The Madison is approved for installation in the U.S. and Canada with double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory . Follow the instructions for assembling and installing double-wall con ...

  • Vermont Casting 410 - page 7

    7 Madison Woodburning Stove 30001453 Connection Above the Fireplace In this installation, the chimney connector enters the fireplace flue through a thimble located above the fireplace. (Fig. 6) The liner of the fireplace chimney should extend at least to the point at which the chim- ney connector enters the chimney . Follow all the guidelines for i ...

  • Vermont Casting 410 - page 8

    8 Madison Woodburning Stove 30001453 Floor Protection A tremendous amount of heat radiates from the bottom plate of your Madison. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox. Heat protection is provided through the use of a Bottom Hea ...

  • Vermont Casting 410 - page 9

    9 Madison Woodburning Stove 30001453 To meet these requirements, a floor protector must be at least 54” (1372mm) wide (“A”,Fig. 12) and 52” (1320mm) deep (“B”, Fig. 12). Fireplace Hearth Protection Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not satisfy the “completely noncombustibl ...

  • Vermont Casting 410 - page 10

    10 Madison Woodburning Stove 30001453 Wall Shields W all shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible material such as 1/2" (13mm) insulation board (Fig. 14) or common brick "laid on flat," with the 3 ¹⁄₂ " (89mm) side down. Shields must be spaced out from the combustible surfa ...

  • Vermont Casting 410 - page 11

    11 Madison Woodburning Stove 30001453 Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations. ALCOVE INSTALLATION OF THE MADISON IS NOT PERM ...

  • Vermont Casting 410 - page 12

    12 Madison Woodburning Stove 30001453 Madison 1655 Series Clearance Chart Use the chart below together with the diagrams on the next page to determine the minimum clearance required for your particular installation. In any case, it is always advisable to locate the stove as far away from walls as pos- sible in order to take full advantage of the ra ...

  • Vermont Casting 410 - page 13

    13 Madison Woodburning Stove 30001453 F F C C A B D E J K L L G H P Q M N I I O O R R V W S T U U X X Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner PROTECTED SURFACES Top Exit Installations, no heat shields Top Exit Installations, heat shield on stove, no shields on single-wall connector Top Exit ...

  • Vermont Casting 410 - page 14

    14 Madison Woodburning Stove 30001453 Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner PROTECTED SURFACES Madison 1655 Series Clearance Diagram UNPROTECTED SURFACES Rear Exit Installations, Bottom Heat Shield, floor protection, minimum 18” (457mm) in front. Y Z AA BB EE FF CC DD N / A N / A Rear Ex ...

  • Vermont Casting 410 - page 15

    15 Madison Woodburning Stove 30001453 Y ou will need the following tools to assemble the Madi- son: • 9/16" open end wrench • safety glasses & gloves • flat head screwdriver • power drill w/ 1/8" (3mm) bit • stub handle phillips screwdriver Unpack the Stove 1. Remove the shipping straps and plastic wrap. 2. Inspect the stove ...

  • Vermont Casting 410 - page 16

    16 Madison Woodburning Stove 30001453 Attach the Chimney Connector Insert the crimped end of the first section of chimney connector into the flue collar . Using the holes in the collar as guides, drill 1/8" (3mm) holes through the connector pipe. Use the three #10 x 1/2" sheet metal screws provided to secure the chimney connection to the ...

  • Vermont Casting 410 - page 17

    17 Madison Woodburning Stove 30001453 How the Madison Works Combustion control is achieved in the Madison through two separate air delivery systems. The primary air control lever , located at the left rear corner of the stove, controls the amount of incoming primary air for starting, maintaining, and reviving the fire. More air entering the stove m ...

  • Vermont Casting 410 - page 18

    18 Madison Woodburning Stove 30001453 Fig. 27 Start a fire with small, dry kindling. ST263 Fig. 28 Gradually add larger pieces of wood until all the wood is burning well. ST264 In newer homes that are well-insulated and weather- tight, poor draft may result from insufficient air in the house. In such cases, a slightly opened window near the stove o ...

  • Vermont Casting 410 - page 19

    19 Madison Woodburning Stove 30001453 NOTE: Some chimneys need to be “primed,” or warmed up, before they will draw sufficiently to sustain a fire. T o correct this situation, roll up a couple pieces of newspaper , place them on top of the kindling and toward the back of the stove, light them, and close the doors. This should heat the chimney en ...

  • Vermont Casting 410 - page 20

    20 Madison Woodburning Stove 30001453 Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Madison looking new. The stove’s paint can be touched up as needed. First, clean the ar ...

  • Vermont Casting 410 - page 21

    21 Madison Woodburning Stove 30001453 The Chimney System Creosote Your Madison is designed to reduce creosote buildup significantly. However, regular chimney inspection and maintenance must still be performed. For safety, good stove performance, and to protect your chimney and chimney connector, inspect your chimney and chimney connector on a regul ...

  • Vermont Casting 410 - page 22

    22 Madison Woodburning Stove 30001453 Your stove is only one part of a system that includes the chimney, the operator, the fuel and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the stove works well. W ood stove operation depends on natural (unforced) draft. Natural d ...

  • Vermont Casting 410 - page 23

    23 Madison Woodburning Stove 30001453 There should be no more than eight feet of single-wall stove pipe between the stove and a chimney . Longer runs can cool the smoke enough to cause draft and creosote problems. Use double-wall stove pipe for longer runs. Single Venting Your stove requires a dedicated flue. Do not connect the stove to a flue used ...

  • Vermont Casting 410 - page 24

    24 Madison Woodburning Stove 30001453 1453 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 45 44 39 37 36 32 28 27 23 15 4 1 35 8 6 2 12 26 42 30 31 20 19 11 22 3 13 9 21 40 29 17 38 14 7 5 18 10 33 16 43 34 24 25 41 46 47 Ma ...

  • Vermont Casting 410 - page 25

    25 Madison Woodburning Stove 30001453 Madison W oodburning Stove Model 1655, 1656, 1657, 1658, 1659 (continued) Item Description Part Number 23. Brick Support 30000804 24. Secondary Air Tube (Rear) 30001493 25. Secondary Air Tube (Middle) 30001494 26. Secondary Air Tube (Front) 30001495 27. Friction Spring 1201846 28. Leveller Blt, Hx Hd 1/4-20 x 1 ...

  • Vermont Casting 410 - page 26

    26 Madison Woodburning Stove 30001453 Shell Enamel Parts - Madison Model 1655 Part Name Classic Green Moonlight Sand Red Suede Brown To p 30000817 30001213 3001203 30001 193 30001 183 30002599 Left Side 30000797 3000121 1 30001201 30001 191 30001 181 30002597 Right Side 30000796 30001210 30001200 30001 190 30001 180 30002596 Flue Collar 7000969 231 ...

  • Vermont Casting 410 - page 27

    27 Madison Woodburning Stove 30001453 W arranty Limited 3 Y ear W arranty CFM Specialty Home Products warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly, handles, glass door panels, cement, and gasketing shal ...

  • Vermont Casting 410 - page 28

    © CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products ...

Manufacturer Vermont Casting Category Stove

Documents that we receive from a manufacturer of a Vermont Casting 410 can be divided into several groups. They are, among others:
- Vermont Casting technical drawings
- 410 manuals
- Vermont Casting product data sheets
- information booklets
- or energy labels Vermont Casting 410
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vermont Casting 410.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vermont Casting 410, service manual, brief instructions and user manuals Vermont Casting 410. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vermont Casting 410.

A complete manual for the device Vermont Casting 410, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vermont Casting 410 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vermont Casting 410.

A complete Vermont Casting manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vermont Casting 410 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vermont Casting 410, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vermont Casting 410, that we can find in the current document
3. Tips how to use the basic functions of the device Vermont Casting 410 - which should help us in our first steps of using Vermont Casting 410
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vermont Casting 410
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vermont Casting 410 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vermont Casting 410?

Use the form below

If you did not solve your problem by using a manual Vermont Casting 410, ask a question using the form below. If a user had a similar problem with Vermont Casting 410 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)