Manual Metrologic Instruments IS8000

40 pages 2.46 mb
Download

Go to site of 40

Summary
  • Metrologic Instruments IS8000 - page 1

    METROLOGIC INSTRUMENTS, INC. HoloTrak ® IS8000 Series Holographic Scanners Installation and User’s Guide ...

  • Metrologic Instruments IS8000 - page 2

    Copyright © 2005 by Metrologic Instruments, Inc. A ll rights reserved. No part of this work may be reproduced, transmitted, or stored in an y form or by any means without prior written consent, except by revie wer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentio ne d in this ...

  • Metrologic Instruments IS8000 - page 3

    T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..................................................................................... 2 Installing the Scanner to t he Host (Standard Features) Single Holotrak ® Installa tion .... ...

  • Metrologic Instruments IS8000 - page 4

    iii ...

  • Metrologic Instruments IS8000 - page 5

    1 I NTRODUCTION Metrologic's IS8000 series scanners bring the b enefits of holography to long- range industrial bar code scanni ng. Enclosed in rugged NEMA-12 cas es for industrial environments, the IS8000 series pr ovides omnidirectional scanni ng with optional no code/ wrong code warning. They can be mounted in an y orientation and are capab ...

  • Metrologic Instruments IS8000 - page 6

    2 S CANNER AND A CCESSORIES The following is a list of parts included in a stand ard IS8000 kit: ¾ IS8000 Series HoloTrak ® Holographic Scanner ¾ Power Supply ¾ [ MLPN 46-46207-US] 12VDC @ 4.16 Amps, 220VAC or ¾ [ MLPN 46-46207-UK] 12VDC @ 4.16 Amps, 240VAC or ¾ [ MLPN 46-46207-EC] 12VDC @ 4.16 Amps, 120VAC ¾ Communication Cable ¾ [ MLPN 52 ...

  • Metrologic Instruments IS8000 - page 7

    3 I NSTALLING THE S CANNER TO THE H OST (S TANDARD F EATURES ) Single HoloTrak ® Installation To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the communications cable to the HoloTrak ® and to the host. 3. Check the AC input requirements of th ...

  • Metrologic Instruments IS8000 - page 8

    4 I NSTALLING THE S CANNER TO THE H OST (S TANDARD F EATURES ) Primary/Secondary setup continued from previous page. All equipment must be connected bef ore powe r-up. After both units complete the power-up diagnostics, the operator will need to program the primary unit with the MetroSet Program provided. Additional Equipme nt needed: Primary/Secon ...

  • Metrologic Instruments IS8000 - page 9

    5 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) Industrial Controller MX001 Interface Option The MX001 Industrial Control Inte rface performs three functi ons. ¾ Through an object sensor input, the scan ner can be alerted to any package present in the scan field. The sensor must have a 12V or 5V at 10mA output signal or switch closu ...

  • Metrologic Instruments IS8000 - page 10

    6 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) External Speaker Box Option When attached, beeper tones from the scanner are emitted from both the scanner speaker and external speaker to serve as an audible indication of the operation of the scanner. There are 6 beeper options available: ¾ Normal Tone ¾ Tone 2 ¾ Tone 4 ¾ Tone 1 ? ...

  • Metrologic Instruments IS8000 - page 11

    7 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) Hand-held Port Option A Non-Decode Hand-Held Scanner can b e connected to an IS8000 series fixed scanner. To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the communications cable to ...

  • Metrologic Instruments IS8000 - page 12

    8 C ONFIGURATION TO THE H OST S YSTEM The scanner is shipped from the factor y c onfigured to a set of default conditions noted in the Default Settings section of this guide. In order for the scanner to communicate with the host system, it will need to be properl y configured. Since each host system is unique, the scanner must be configured to matc ...

  • Metrologic Instruments IS8000 - page 13

    9 I NSTALLING AND R UN N I N G THE M E T R O S E T ® 2 P ROG R A M How to Start To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host. 1. Turn off the PC after installing the MetroSet 2 program. 2. Connect the communication cable to the scann er and to the RS-232C serial port (COM1 or COM2 ...

  • Metrologic Instruments IS8000 - page 14

    10 P ARTS OF THE S CANNER c Green and Red LEDs The red LED is on when the unit is done p ower up, the VLD is emitting light and the unit is ready to scan. The green LED flas hes when the scanner has read a bar code successfully. The functions of the LED' s can be reversed through special conf iguration with the MetroSet ® 2 conf iguration pro ...

  • Metrologic Instruments IS8000 - page 15

    11 M OUNTING B RACKET I NSTALLATION 1. Locate the mounting bolts on the sides of the scann er. 2. Align the bolts on the scanner with the cha nnels on the mounting bracket. 3. Slide the unit into pl ace until the scanner b olts sit securely in the bottom of the channels. 4. Rotate the unit to the desired angle an d secure into place with a locking ...

  • Metrologic Instruments IS8000 - page 16

    12 V ISUAL AND A UDIBLE I NDICATORS When the scanner is on, the acti vity of the red and green L EDs indicate the status of the scanner. Flashing Red, No Green During power-up and diagn ostic mode. Steady Red, No Green Unit has completed po wer-up, the VLD is emitting light, and the unit is ready to scan. Steady Red, Green Flash When the scanner tr ...

  • Metrologic Instruments IS8000 - page 17

    13 L ABELS – A C D B ...

  • Metrologic Instruments IS8000 - page 18

    14 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8300 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.25 mm/0.010” bar code width. A ctual scan areas will vary by label size and application. ...

  • Metrologic Instruments IS8000 - page 19

    15 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8400 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.33 mm/0.013” bar code width. A ctual scan areas will vary by label size and application. ...

  • Metrologic Instruments IS8000 - page 20

    16 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8500 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.33 mm/0.013” bar code width. A ctual scan areas will vary by label size and application. ...

  • Metrologic Instruments IS8000 - page 21

    17 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8800 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.33 mm/0.013” bar code width. Actual scan areas will vary by label size and application. ...

  • Metrologic Instruments IS8000 - page 22

    18 M AINTENANCE Smudges and dirt can interfere with the proper scanni ng of a bar code. Therefore, the output window w ill ne ed occasional cleanin g. 1. Spray optical qualit y cleaning fluid ont o l int free, nonabrasive cleanin g cloth. 2. Gently wipe the output window. Do not use solvents like alchohol or acetone. T hese materials can damage the ...

  • Metrologic Instruments IS8000 - page 23

    19 T ROUBLESHOOTING G UIDE P ROBLEM P OSSIBLE C AUS E ( S ) A CTION N EEDED No LEDs No Power No Scan Pattern No Power Check the power supply and outlet. Alternating Red and Green LEDs flash with a razz tone. Motor Failure Contact a Metrologic service representative. The communication cable is not connected to the COM port. Check the communication c ...

  • Metrologic Instruments IS8000 - page 24

    20 A PPENDIX A Design Specifications IS8800 IS85 00 IS8400 IS8300 Optical Number of VLD 5 5 3 5 Scan pattern Omni Omni Omni Omni Scan l ines pe r sec ond 5,600 5,600 3,360 5,250 Focal planes 4 4 4 5 Scan l ines pe r foca l plane 20 20 12 15 Total scan lines 80 80 48 75 Minimum bar width 0.30 mm/0.012” 0.25 mm/0.010” 0.25 mm/0.010” 0.20 mm/0.0 ...

  • Metrologic Instruments IS8000 - page 25

    21 A PPENDIX A ( CONTINUED ) Design Specifications IS8800 IS85 00 IS8400 IS8300 Electrical Input Voltage 12 VDC 12 VDC 12 VDC 12 VDC Starting Power 69 watts 69 w atts 53 watts 53 watts Operating power 43 watts 43 watts 34 watts 34 watts EMC: FCC, ICES-003 & EN 55022 Class A Class A Class A Class A Laser Wavelength 658 nm ± 5 nm 658 nm ± 5 nm ...

  • Metrologic Instruments IS8000 - page 26

    22 A PPENDIX B Default Settings Many functions of the scanner can be configured, or enab led/disabled. The factory programs the scanner to a set of default parameters. T hese defaults are marked with an asterisk (*) in the default column on the foll owing pages. Unmarked parameters show the unavail abi lity for that protocol. To speak with the host ...

  • Metrologic Instruments IS8000 - page 27

    23 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN 200 msec to find Supps 999 Code 128 Coupon Option 999 Code 128 Coupon Conversion 999 378/379 lock on supplement 999 Remote supplement required 999 MISCELLANEOUS Beep after transmitting 999 Beep before transmitting * 999 Faster Beep/Same Tone 999 Lost Communication Timeout ...

  • Metrologic Instruments IS8000 - page 28

    24 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Fire triac if goo d read/match 999 Fire triac i f bad match 999 Fire triac if no read 999 Triac Duration (sec.) 999 Delay Time before firing ( sec.) 999 Enable programmable 'No Read' message 999 Retain same sy mbol timers along with line sensor 999 Supports dual ...

  • Metrologic Instruments IS8000 - page 29

    25 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Transmit SANYO ID Chr 99 SNI Beetle Mode 9 9 French PC Term not currently supported 99 Xon/Xoff handshaking 9 9 Programmable prefix identi fiers 99 Xmit (dec) as 1st prefix identifi er Xmit (dec) as 2nd pr efix identifi er Programmable suffix identifier s 9 9 Xmit (dec) a ...

  • Metrologic Instruments IS8000 - page 30

    26 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Transmit Code 39 Start/Stop Chara cters 99 Transmit ITF Mod 10 check digi t 9 9 Transmit Code 39 Mod 43 check digi t 99 SYMBOL LENGTH ITF(variable length-50 char ) 14 char lock 999 Min 1-50 4 999 Lock 0-50 0 999 BEEPER TONE Normal, Alt1 , Alt 2, Alt3 , Alt4, N one Normal ...

  • Metrologic Instruments IS8000 - page 31

    27 A PPENDIX C IS8000 Series Pinout Connections D ESCRIPTION P IN S IGNAL 1G r o u n d 2 RS-232 Receive Input 3 RS-232 Transmit Output 4 CTS Input 5 RTS Output 6 Reserved 7G r o u n d 8 Reserved 9 RS-422 Receive – (B-) 10 RS-422 Receive + (A+) Connector Type on Scanner DB25P (D-Type 25 Pin Male) 11 RS-422 Send + (Y+) 12 RS-422 Send – (Z-) 13 Gr ...

  • Metrologic Instruments IS8000 - page 32

    28 A PPENDIX C IS8000 Series Pinout Connections D ESCRIPTION P IN S IGNAL 1 12VDC Input Power t o Scanner 2 12VDC Input Power t o Scanner 3 Earth Ground 5 Power Ground 4 Power Ground Connector Type on Scanner: DEC9P (D-Type 9-Pin Male) 6 12VDC Input Power t o Scanner 7 12VDC Input Power t o Scanner 8 Power Ground Function: Power Port 9 Power Ground ...

  • Metrologic Instruments IS8000 - page 33

    A PPENDIX D Limited Warranty The IS8000 series scanners are manufactured by Metrologic at its Blackwood, New Jerse y, U.S.A. facility. The IS8000 series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS8000 series scanners are free of all defects in material, wo rkmanship and ...

  • Metrologic Instruments IS8000 - page 34

    30 A PPENDIX E Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. T hese limits are designed to provide reasona ble protection against harmful interference when the equipment is operate d in a commercial environment. This equipment generates, uses and can radiat ...

  • Metrologic Instruments IS8000 - page 35

    31 A PPENDIX E ( CONTINUED ) Ach tu ng Die Verwendung anderer als der hier beschrieben en Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kund e sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanne ...

  • Metrologic Instruments IS8000 - page 36

    32 A PPENDIX F Patents "Patent Informa tion This M ETROLOG IC product may be covere d by on e or more of t he follow ing U.S. Patents: U.S. Patent No.; 5,081,34 2; 5,260 ,553; 5,343, 027; 5,6 86,717; 5,777,3 15; 5,828,049; 5,975, 419; 5,984,1 85; 6,00 3,772; 6 ,006,993; 6,0 24,282; 6,062,479; 6,073, 846; 6,076,7 36; 6,08 5,978; 6 ,085,98 0; 6, ...

  • Metrologic Instruments IS8000 - page 37

    33 I NDEX A ac input/outlet ............. 3-7, 9, 21, 28 accessori es ................................... 2 approvals ......... 4, 13, 20, 21, 30, 31 assignments pin ................................ 10, 27, 28 audible ............................... 6, 10, 12 B bar code ............ 1, 5, 10, 12, 18, 24 bar widt h .................................. ...

  • Metrologic Instruments IS8000 - page 38

    34 I NDEX specificati ons ......................... 20, 21 system interfaces .......... 1, 8, 20, 22 T tones.............................................. 6 transforme rs .................................. 9 troubleshoot ing ............................ 19 V ventilat ion .................................... 21 visual ............................... ...

  • Metrologic Instruments IS8000 - page 39

    C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUA RTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICA N H EAD QUA RT ERS USA, New Jerse y Germany, Munich Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax : 856-228-6673 Tel: 49-89-89019-0 Fax : 49-89-89019-200 Email: info@metrologic.com Em ail: ...

  • Metrologic Instruments IS8000 - page 40

    March 2005 Printed in the USA 00 - 02377A ...

Manufacturer Metrologic Instruments Category Scanner

Documents that we receive from a manufacturer of a Metrologic Instruments IS8000 can be divided into several groups. They are, among others:
- Metrologic Instruments technical drawings
- IS8000 manuals
- Metrologic Instruments product data sheets
- information booklets
- or energy labels Metrologic Instruments IS8000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic Instruments IS8000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic Instruments IS8000, service manual, brief instructions and user manuals Metrologic Instruments IS8000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic Instruments IS8000.

A complete manual for the device Metrologic Instruments IS8000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic Instruments IS8000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic Instruments IS8000.

A complete Metrologic Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic Instruments IS8000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic Instruments IS8000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic Instruments IS8000, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic Instruments IS8000 - which should help us in our first steps of using Metrologic Instruments IS8000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic Instruments IS8000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic Instruments IS8000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic Instruments IS8000?

Use the form below

If you did not solve your problem by using a manual Metrologic Instruments IS8000, ask a question using the form below. If a user had a similar problem with Metrologic Instruments IS8000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)