Manual Fujitsu TX300

122 pages 6.09 mb
Download

Go to site of 122

Summary
  • Fujitsu TX300 - page 1

    Options Guide - English PRIMERGY TX300 S6 Server Options Guid e Edition August 2010 ...

  • Fujitsu TX300 - page 2

    Comments … Suggestions … Corrections … The User Documentation Depar tment would lik e to know y our opinion of this manual. Y our f eedback helps us optimize our documentation to suit y our indivi dual needs. F eel free to se nd us your comments by e-mail to email: manuals@ts.fujitsu.com . Certified documentation according to DIN EN IS O 9001 ...

  • Fujitsu TX300 - page 3

    TX300 S6 Options Guide Before reading this manual For your safety This manual c ontains important information for s af ely and correctly using this product. Carefully read the manual bef ore using this product. P a y par ticular attention to the accompan ying manual "Saf ety Notes and Regulations" and ensure these saf ety notes are unders ...

  • Fujitsu TX300 - page 4

    Optio ns Guide T X 300 S6 These uses include control of nuclear reactions in n uclear power plants , automatic airplane flight control, air traffic control, traffic control in mas s transport systems, medical de vices for lif e suppor t, and missile guidance control in weapons systems (hereafter , "high saf ety use"). Cus tomers should no ...

  • Fujitsu TX300 - page 5

    TX300 S6 Options Guide Only f o r the Japanese market: I Although described in this manual, some s ections do not apply to the Japanes e market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Sel f Service) ...

  • Fujitsu TX300 - page 6

    Optio ns Guide T X 300 S6 ...

  • Fujitsu TX300 - page 7

    TX300 S6 Options Guide Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.1 Concept and target groups . . . . . . . . . . . . . . . . . . 12 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 12 1.3 Expansions and conver sions . . . . . . . . . . . . . . . . . 14 1.4 Notational con ventions . . . . . . . ...

  • Fujitsu TX300 - page 8

    Optio ns Guide T X 300 S6 Contents 6 Processor s . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 6.1 Installing a second processor . . . . . . . . . . . . . . . . . 42 6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 47 6.3 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . . 52 7 Accessible drives and LSD ...

  • Fujitsu TX300 - page 9

    TX300 S6 Options Guide Contents 11 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 11.1 Installing the fan carrier . . . . . . . . . . . . . . . . . . . . 105 11.2 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 107 11.2.1 Mounting the ser v er f eet . . . . . . . . . . . . . . . . . . . . . 107 11.2.2 Attachin ...

  • Fujitsu TX300 - page 10

    Optio ns Guide T X 300 S6 Contents ...

  • Fujitsu TX300 - page 11

    TX300 S6 Options Guide 11 1 Preface With top dual processor perf ormance, the PRIMERGY TX300 S6 tow er ser v er is an all-purpose ser ver f or medium sized companies and branches of l arge enterpr ises. The system is ideal f or use as a versatile b usiness ser ver f or bu siness critical applications and dedicated tasks . Thanks to internal SAS/SA ...

  • Fujitsu TX300 - page 12

    12 Options Guide TX300 S6 Concept and targ et groups Preface 1.1 Concept and target gr oups This Options Guide shows y ou how to ex tend and upgrade y our s erver . V CA UTION! The activities described in this manual m a y only be perf or med by techn ical spec iali sts. I The installation and remo val of the hot-plug comp onents is described in th ...

  • Fujitsu TX300 - page 13

    TX300 S6 Options Guide 13 Preface Documentation o verview I PRIMERGY manuals are a vailab le in PDF f or mat on the Ser v erVie w Suite D VD 2. The ServerVie w Suite D VD 2 is part of the Ser v erVie w Suite supplied with e very ser ver . If you no l onger hav e the Ser verVie w Suite D VDs, you c an obtain the relev ant current versions using the ...

  • Fujitsu TX300 - page 14

    14 Options Guide TX300 S6 Expansions and conver sions Preface 1.3 Expansions and con versions Main memory The system board offers 18 slots f or memor y modules . 9 memor y slots can be used in mono processor configur ations. ECC with memory scr ubbing and the Single De vice Data Correction (SDDC) function is standard. There are three modes of opera ...

  • Fujitsu TX300 - page 15

    TX300 S6 Options Guide 15 Preface Expansions and conversions LSD/LSP The system board suppor ts the CSS (Customer Self Ser vice) functionality (description see the Operating Manual ). Y ou can instal l a ServerView Loc al Service Display (LSD) or ServerVie w Local Service P anel (LSP) for an easier identification of the def ective components. Addit ...

  • Fujitsu TX300 - page 16

    16 Options Guide TX300 S6 Nota tional con ven tion s Preface – If a f ailure occurs, please inform your service about the TPM activ ation bef ore it takes an y action, and be prepared to pro vide them with you r back up copies of the TPM content. USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). This module can be u ...

  • Fujitsu TX300 - page 17

    TX300 S6 Options Guide 17 2P r o c e d u r e V CA UTION! ● The actions described in this manual shall be perf or med by technical specialists. A techni cal specialist is a person who is trained to install the server including hardware and softw are. ● Repairs to the de vice that do not relate to CSS f ailures shall be performed by service perso ...

  • Fujitsu TX300 - page 18

    18 Options Guide TX300 S6 Procedure ...

  • Fujitsu TX300 - page 19

    TX300 S6 Options Guide 19 3 Safety instructions I The fo llowing saf ety instructions are also provided i n the manual "Saf ety Notes and Regulations". This de vice meets the relev ant safety regulations f or IT equipment. If you hav e any questions about whether y ou can install the ser ver in the i ntended envi ronment, please contact y ...

  • Fujitsu TX300 - page 20

    20 Options Guide TX300 S6 Safety instructions Bef ore startin g up V CA UTION! ● During installation and bef ore operating the device , obser v e the instructions on en vironmental conditions f or your device . ● If the device is brought in from a cold environment, condensation ma y form both inside and on the outside of the de vice. W ait unti ...

  • Fujitsu TX300 - page 21

    TX300 S6 Options Guide 21 Safety instructions V CA UTION! ● Ensure that the power so ck ets on the device and the properly grounded po wer outlets are freely accessibl e. ● The On/Off button or the main po wer switch (if present) does not isolate the de vice from the mains power supply . T o disconnect it completely from the mains po wer supply ...

  • Fujitsu TX300 - page 22

    22 Options Guide TX300 S6 Safety instructions V CA UTION! ● Proper operation of the system (in accordance with IEC 60950-1/2 resp . EN 60950-1/2) is only ensured if the c asing is completely assembled and the rear co v ers f or the installation slots ha ve been fitted (electric shock, cooling, fire protection, interf erence suppression). ● Only ...

  • Fujitsu TX300 - page 23

    TX300 S6 Options Guide 23 Safety instructions V CA UTION! ● Install the screw remo v ed dur ing installation/detaching Internal Options in f ormer device/position . T o use a screw of the diff erent kind causes a breakdown of equipment. ● The installation indi cated on this note is sometimes c hanged to the kind of possible opti ons without not ...

  • Fujitsu TX300 - page 24

    24 Options Guide TX300 S6 Safety instructions ● Shock s and vibrations are also to be av oided. ● Do not inser t any objects other than t he specified CDs/D VDs/BDs. ● Do not pull on, press hard, or ot herwise handle the CD/D VD/BD tra y roughly . ● Do not disassemb le the optical drive . ● Bef or e use, clean the opti cal disk tra y usin ...

  • Fujitsu TX300 - page 25

    TX300 S6 Options Guide 25 Safety instructions I Y ou can pre v ent damage from the optical dr iv e and the CDs/D VDs/BDs, as well as premature wear o f the disks , by observing the f ollowing suggestions: – Only inser t disks in the drive when nee ded and remov e them after use. – Store the disks in suitab le slee ves . – Protect the disks fr ...

  • Fujitsu TX300 - page 26

    26 Options Guide TX300 S6 Safety instructions ● W ear a suitabl e grounding cab le that connects you to the e xter nal chassis of the system unit. ● Alwa ys hold components with ESDs at the edges or at the points marked green (touch points). ● Do not touch any connectors or conduction paths on an ESD . ● Place all the components on a pad wh ...

  • Fujitsu TX300 - page 27

    TX300 S6 Options Guide 27 4 Preparation V CA UTION! ● Before remo ving or attaching cov ers, tur n off the server , all peripheral dev ices, and an y other c onnected de vices. A lso unplug all po wer cords from the power outl et. F ailure to do so can cause electric shock. ● Only f or rac k model: Use the anti-tilt plate to pre vent the r ack ...

  • Fujitsu TX300 - page 28

    28 Options Guide TX300 S6 Floorstand model Preparation 4.1 Floorst and model I F or s ome e x pansions and con versions, it i s advisab le to la y the ser ver on its right-hand side and to remove the s er v er f eet. 4.1.1 Opening the server Ê T er minate all applications and shut do wn the s erver correctly . Ê If your oper ating system has not ...

  • Fujitsu TX300 - page 29

    TX300 S6 Options Guide 29 Preparation Floorstan d model 4.1.2 Remo ving the fr ont cov er Remov e the front cov er when making the f ollo wing routines: – Installing/remo v ing accessib le drives – Conv ersion from a floorstand model to a rack model Figure 3: Removing t he dr ive co ver and the HDD cov er Ê Unlock the ser ver and remo ve the k ...

  • Fujitsu TX300 - page 30

    30 Options Guide TX300 S6 Floorstand model Preparation Figure 4: Pulling out the lock ing b uttons Ê Pull out the two g reen locking b uttons (1). Figure 5: Removing the front c ov er Ê Pull the front co v er forw ard slightly at the lower edge . Ê Unhook the front cov er at the top and remov e it. 햲 햲 ...

  • Fujitsu TX300 - page 31

    TX300 S6 Options Guide 31 Preparation Floorstan d model 4.1.3 Remo ving the server f e et Figure 6: Removing t he server f eet Ê If necessary , remove the server f eet. T o do this, yo u need to loosen four scre ws on each of the f eet (see circles). ...

  • Fujitsu TX300 - page 32

    32 Options Guide TX300 S6 Rack model Preparation 4.2 Rac k model Ê T er minate all applications and shut do wn the s erver correctly . Ê If your oper ating system has not switched off the s er ver , pres s the On/Off button. Ê Pull all po wer cords out of the power outlet. 4.2.1 Opening the server Pulling the server out of the rack and opening t ...

  • Fujitsu TX300 - page 33

    TX300 S6 Options Guide 33 Preparation Rack model Removing the server from the rack and opening the server Depending on how accessib le the ser v er is in the rack cabinet, it can mak e sense to remov e the ser ver from the rac k cabinet. I Removing the server from the rac k may be diff erent. In this case you will find the description in the pac k ...

  • Fujitsu TX300 - page 34

    34 Options Guide TX300 S6 Rack model Preparation 4.2.2 Remo ving the rac k fr ont co ver Y ou remo ve the rac k front cov er when mak ing the f ollowi ng routines: – Installing/remo ving accessible dr ives Figure 9: Removing the rac k front cover Ê Remov e two knurled screws on either side (1). Ê Remov e the rack front cov er to the front toget ...

  • Fujitsu TX300 - page 35

    TX300 S6 Options Guide 35 Preparation Removing the fan carrier 4.3 Remo ving the fan carrier Figure 10: Disconnecting t he power cable Ê Disconnect the pow er c able from the f an backplane (1). Ê Open the cab le clamp and take o ut the power c able (2). Ê Loosen the three knurled screws of the f an carr ier (3). 0 1 2 2 2 ...

  • Fujitsu TX300 - page 36

    36 Options Guide TX300 S6 Removing the fan carrier Preparation Figure 11: Removing the f an carrier Ê Push the fa n c arrier in the direction of the front side (1 ). Ê T ake the f an carrier out of the s erver (2). V CA UTION! Ensure that y ou do not damage the SAS cab les when sliding the f an carrier in or lifting it out. 1 0 ...

  • Fujitsu TX300 - page 37

    TX300 S6 Options Guide 37 5M a i n m e m o r y V CA UTION! ● Before i ns talling/removing m emor y to/from the ser v er , tur n off the server , all peripheral de vices, and an y other connected de vices. A lso unplug all po wer cords from the power outl et. F ailure to do so can cause electric shock. ● A memory module consists of par ts that a ...

  • Fujitsu TX300 - page 38

    38 Options Guide TX300 S6 Memory mod ules Main memory 5.1 Memory modules The system board offers 18 slots f or memor y modules . 9 memor y slots can be used in mono processor configur ations. ECC with memory scr ubbing and with the Single De vice Data Correction (SDDC) function is suppor ted. There are three modes of operation f or the main memor y ...

  • Fujitsu TX300 - page 39

    TX300 S6 Options Guide 39 Main memory Memory modules Figure 12: Extract from the c onfigurator (EMEA market) I The current configurator can be f ound under : http://ts.fujitsu.com/pr oducts/standar d_server s /tower/primergy_tx300s6.h tml (for the EMEA mar ket) http://primeserver .fujitsu.com/primergy/system.h tml (f or the Japanese market) Sy stem ...

  • Fujitsu TX300 - page 40

    40 Options Guide TX300 S6 Ex pand ing the m ain memory Main memory 5.2 Expanding the main mem ory Ê Open the server and remov e the f an carr ier as described in the chapter "Preparation" on page 27 . Figure 13: Removing a m emory module Ê Press the securing clips on both sides of the memory slot concer ned outward (1). Ê If the slot w ...

  • Fujitsu TX300 - page 41

    TX300 S6 Options Guide 41 6 Pr ocess ors V CA UTION! ● Before ins talling/removing process ors to/from the server , tur n off the server , all peripheral de vices, and an y other connected de vices. A lso unplug all po wer cords from the power outl et. F ailure to do so can cause electric shock. ● Do not touch the circuitr y on boards and solde ...

  • Fujitsu TX300 - page 42

    42 Options Guide TX300 S6 Installing a second processor Processors 6.1 Installi ng a second processor The system board can be upgraded with a second processor . T he upgr ade kit consists of a processor and a heat sink. V CA UTION! Only processors of the same type ma y be used on the system board. That means the number of the internal processor cor ...

  • Fujitsu TX300 - page 43

    TX300 S6 Options Guide 43 Processors Installing a second processor Figure 16: Opening the processor holder and removing the soc ket cov er Ê Press the spring clip downward and outw ard. Ê F old bac k the spring clip (1). Ê F old bac k the processor holder (2). Ê Hold the soc ket cov er by the tw o grips between y our thumb and inde x finger and ...

  • Fujitsu TX300 - page 44

    44 Options Guide TX300 S6 Installing a second processor Processors Figure 17: Inser ting and loc k ing the processor Ê Hold the processor between y our thumb and inde x finger and ali gn it at the sock et coding (see c ircle). V CA UTION! The processor can only be installed in one particular direction. Ê Place the processor in the sock et with gr ...

  • Fujitsu TX300 - page 45

    TX300 S6 Options Guide 45 Processors Installing a second processor Figure 18: Removing the protecti ve co ver Ê Remov e the protective co ver on the underside of the heat sink. V CA UTION! Do not touch the thermal paste on the underside of the heat sink. ...

  • Fujitsu TX300 - page 46

    46 Options Guide TX300 S6 Installing a second processor Processors Figure 19: Mounting and locking the heat s ink Ê Align the heat sink on the processor soc k et so that the side with the visib le copper heat pipes is po inting in the direction of the mem or y slots. Ê F old down the tw o heat sink retaining clips at the same time and loc k the h ...

  • Fujitsu TX300 - page 47

    TX300 S6 Options Guide 47 Processors Replacing the processor 6.2 Replacing the pr o cessor V CA UTION! Only processors of the same type may be used on the system board. That means the number of the internal processor c ores as well as the primar y clock and the FSB frequency ha ve to be the same. F or dual operation, use a suitab le multiprocessor ...

  • Fujitsu TX300 - page 48

    48 Options Guide TX300 S6 Replacing the processor Processors Removing an old processor Figure 21: Removing an old processor Ê Press the spring clip downward and outw ard. Ê F old bac k the spring clip (1). Ê F old bac k the processor holder (2). Ê Lift the installed processor carefull y out of the sock et (3). V CA UTION! Do not bend the spring ...

  • Fujitsu TX300 - page 49

    TX300 S6 Options Guide 49 Processors Replacing the processor Insert ing and locking a new processor Figure 22: Inser ting and locking a new processor Ê Hold the processor between y our thumb and index finger and a lign it at the soc ket coding (see circle). V CA UTION! The processor can only be ins tal led in one par ticular direction. Ê Place th ...

  • Fujitsu TX300 - page 50

    50 Options Guide TX300 S6 Replacing the processor Processors Figure 23: Applying and distributing ther mal paste Ê Apply a small amount of thermal paste to the upper side of the ne w processor . Ê Ensure a thin and e ven distribution of the thermal paste. ...

  • Fujitsu TX300 - page 51

    TX300 S6 Options Guide 51 Processors Replacing the processor Mounting and lo cking the heat sink Figure 24: Mounting and locking the heat sink Ê Align the heat sink on the processor soc ket s o that the side with the visib l e copper heat pipes is pointing in the direction of the memory slots. Ê F old down the tw o heat sink retaining clips at th ...

  • Fujitsu TX300 - page 52

    52 Options Guide TX300 S6 Replacing the heat sink Processors 6.3 Replacing the heat sink Ê Open the server and remov e the f an carr ier as described in the chapter "Preparation" on page 27 . Ê Remov e the heat sink as described in the s ection "Replacing the proces sor" on page 47 . Ê Remov e the protective cov er from the n ...

  • Fujitsu TX300 - page 53

    TX300 S6 Options Guide 53 7 Acces sible drives and LSD/LSP V CA UTION! ● Befo re installing/remo ving an accessible driv e to/from the ser ver , turn off the server , all peripheral devices , and any other connected dev i ces. Also unplug all power cords from the po wer outlet. F ailure to do so can cause electric shock. ● When installing an ac ...

  • Fujitsu TX300 - page 54

    54 Options Guide TX300 S6 Equipping o f the bays Accessible drives and LS D/LSP 7.1 Equipping o f the bays Three 5.25-inch ba y s are av ailable f or accessible driv es. Y ou can install D VD drives , magnetic tape drives, a Multi bay 1 (slimli ne D V D drive and Serv erVie w LSP or LSD), or an HDD e xtension bo x in these bays. Figure 25: Bays for ...

  • Fujitsu TX300 - page 55

    TX300 S6 Options Guide 55 Accessible drives and LS D/LSP Equipping of the bays Recommended equipping of the ba ys: Order Installed accessible drive Bay Max. numb er Bays occupied Interface 1. Multiba y 1 with slimline D V D drive 3 top 1 1 x 0.5" x 5.25" SAS 1. Multibay 1 with LSD or LSP 3 bottom 1 1 x 0.5" x 5.25 I²C bus 1. D VD dr ...

  • Fujitsu TX300 - page 56

    56 Options Guide TX300 S6 Accessible 5.25-inch drive Accessible drives and LS D/LSP 7.2 Accessib le 5.25-inch drive Ê Open the server and remov e the the front cov er or the rack front cov er as described in the chapter "Preparation" on page 27 . I Ne w 5.25-inch drives are supplied wi thout EasyClic k rails . Before installing a ne w 5. ...

  • Fujitsu TX300 - page 57

    TX300 S6 Options Guide 57 Accessible drives and LS D/LSP Accessible 5.25-inch drive Figure 27: Detaching the EasyClic k rails from the dummy c ov er Ê Detach the EasyClic k rails from the dummy cov er by removing th e f our screws on each side. I Note that there are two M3 x 4.5mm scre ws with M3 thread (yello w ellipse) and two 6-32 x 4.8mm s cre ...

  • Fujitsu TX300 - page 58

    58 Options Guide TX300 S6 Accessible 5.25-inch drive Accessible drives and LS D/LSP 7.2. 2 Installing a n acce ssib le 5.2 5-inch drive Figure 28: Attaching the EasyClick rails - example: D VD drive Ê Screw the EasyCl ick rails onto either side of the ne w 5.25-inch drive u sing two M3x4.5mm sc rews . Use the first hole in each lo wer row of holes ...

  • Fujitsu TX300 - page 59

    TX300 S6 Options Guide 59 Accessible drives and LS D/LSP Multibay 1 7.3 Multiba y 1 Ê Open the ser ver and remo ve the the front cov er or the rac k front cov er as described in the chapter "Preparation" on page 27 . Ê Remov e the dummy cov er fr om the ba y 3 (see section "Equipping of the bay s" on page 54 and section " ...

  • Fujitsu TX300 - page 60

    60 Options Guide TX300 S6 Multibay 1 Accessible drives and LSD/LSP Figure 30: Sliding t he LSP in the 3.5-inch frame Ê Slide the LSD/LSP in the 3.5-inch frame from the front until it engages (see the snap-in hook in the circle). Figure 31: Sliding the 3.5-inch f rame with LSP in M ultiba y 1 Ê Slide the 3.5-inch fr ame with the LSP/LSD from the r ...

  • Fujitsu TX300 - page 61

    TX300 S6 Options Guide 61 Accessible drives and LS D/LSP Multibay 1 Figure 32: Fasteni ng the 3.5-inch frame with LSP in Multibay 1 Ê F asten the 3.5-inch frame using two M3 x 6 mm scre ws on either side. 7.3.1.2 Installing a slimline DVD drive Figure 33: Inser ting a slimline D VD dr ive in the frame Ê Inser t the slimlin e D VD dr ive in the fr ...

  • Fujitsu TX300 - page 62

    62 Options Guide TX300 S6 Multibay 1 Accessible drives and LSD/LSP Figure 34: Connecting the PS adapter cable to the D VD dr ive Ê Connect the PS adapter cable to the D VD drive (see the cabl ing plans in the Appendix). ...

  • Fujitsu TX300 - page 63

    TX300 S6 Options Guide 63 Accessible drives and LS D/LSP Multibay 1 Figure 35: Inser ting the DV D drive module in the M ultiba y 1 Ê F rom the front, inser t the D VD dr ive module into Multiba y 1 until it engages (see locking latc h in circle). Figure 36: Attaching EasyClick rails to Multiba y 1 Ê Screw the Eas yClic k rails onto either side u ...

  • Fujitsu TX300 - page 64

    64 Options Guide TX300 S6 Multibay 1 Accessible drives and LSD/LSP 7.3.2 Insta lling Multiba y 1 Figure 37: Connecting the SA T A cable t o the D VD drive Ê Pull the SA T A cable (1) out of the hous ing through the drive cage . Ê Connect the SA T A cable to the D VD drive (2) (see the cab ling plans in the Appendix). 햳 햲 ...

  • Fujitsu TX300 - page 65

    TX300 S6 Options Guide 65 Accessible drives and LS D/LSP Multibay 1 Figure 38: Installing Multib a y 1 Ê Push Multiba y 1 fully into ba y 3 until the EasyClic k rails loc k in place. Ensure that no damage is caused to the cab les. ...

  • Fujitsu TX300 - page 66

    66 Options Guide TX300 S6 Multibay 1 Accessible drives and LSD/LSP Figure 39: Connecting the PS adapter cable to the power cable Ê Connect the PS adapter cab le to the CON.2 or CON.4 or CO N.6 connector of the power cab le (see the cabling plans in the A ppendix). Figure 40: Routing the power cable Ê Route the power cab le using the cable clamps ...

  • Fujitsu TX300 - page 67

    TX300 S6 Options Guide 67 Accessible drives and LS D/LSP Multibay 1 Figure 41: Connecting the I 2 C cable to the L SP/LSD Ê Remov e the cable tie of the I 2 C cab le near the CON.4 connector . Ê Connect the I 2 C cable CON.4 connector to the LSP/L SD (see the cabling plans in the Appendix). Ê Attach the front cov er or the rack front co ver as d ...

  • Fujitsu TX300 - page 68

    68 Options Guide TX300 S6 HDD extension box Accessible drives and LS D/LSP 7.4 HDD extension bo x In the base units two 5.25-inch bay s f or accessib le drives can be used to install an HDD e x tension bo x. T wo v ar iants of the HDD extension bo x are av ailab le: ● HDD ex tension bo x f or 3.5-inch HDD modules (Multibay 2): Multiba y 2 contain ...

  • Fujitsu TX300 - page 69

    TX300 S6 Options Guide 69 Accessible drives and LS D/LSP HDD extension box 7.4.1 M ulti bay 2 Multiba y 2 contains one bay f or a LSP or LSD , one bay f or a D VD dr ive , and two ba y s f or 3.5-inch HDD modules. Figure 42: Attaching EasyClick rails to Multiba y 2 Ê Screw the Eas y Click r ails onto either side using two M3 x 4.5 mm scre ws. Use ...

  • Fujitsu TX300 - page 70

    70 Options Guide TX300 S6 HDD extension box Accessible drives and LS D/LSP 7.4.1.1 Installing Multibay 2 When installing Mul tiba y 2, proceed in a similar wa y as for install ing Multiba y 1. See section "Installi ng Multiba y 1" on page 64 on how to connect the SA T A cabl e to the D VD dr ive and connect the PSU adapter cab le to the p ...

  • Fujitsu TX300 - page 71

    TX300 S6 Options Guide 71 Accessible drives and LS D/LSP HDD extension box Figure 44: Cabling SAS cable Ê Connect the SAS cable included to the connector X1 of the HDD backplane of the Multiba y 2 (1). Ê Connect the SAS cab le included to the connector MLC2 of the 3.5- inch HDD back plane (2). Ê Route the SAS cab le through the cabl e guides as ...

  • Fujitsu TX300 - page 72

    72 Options Guide TX300 S6 HDD extension box Accessible drives and LS D/LSP Ê Close the ser v er , connect it to the power outlet, and s witch it on as des cribed in the chapter "Completion" on page 105 . 7.4.2 2.5-inch HDD extension bo x The HDD ex tension bo x f or 2.5- inch HDD modules contains eight ba y s f or 2.5- inch HDD modules. ...

  • Fujitsu TX300 - page 73

    TX300 S6 Options Guide 73 Accessible drives and LS D/LSP HDD extension box 7.4.2.1 Installing 2.5 inch HDD extension box Figure 46: Connecting PS adapter cable to HD D backplanes Ê Connect the PS ad apter cab les to the tw o HDD bac k planes at the rear side of the HDD ex tension bo x (X6 connectors). Ê Push the HDD e xtension bo x fully into bay ...

  • Fujitsu TX300 - page 74

    74 Options Guide TX300 S6 HDD extension box Accessible drives and LS D/LSP Figure 47: Cab ling 2.5-inch HDD ext ension bo x Ê Connect the PS adapter cables to the CON.2 and CON.4 connectors of the pow e r c a bl e. Ê Connect the SAS cab les included in the con version kit to the SAS connectors on the HDD backplanes (see circle). Observe the label ...

  • Fujitsu TX300 - page 75

    TX300 S6 Options Guide 75 8 Expansion cards and BB U V CA UTION! ● Before i ns talling/remo vi ng e x pansion cards to/from the server , turn off the server , all peripheral devices , and any other connected dev ices. Also unplug all pow er cables from the po wer outlet. F ailure to do so can cause electric shock. ● The circuit boards and s old ...

  • Fujitsu TX300 - page 76

    76 Options Guide TX300 S6 Installing expansion cards Expansion cards and BBU 8.1 Installing expansion cards The system board has se ven PCI Express slots. Slots 1-5 are connected as x4 interf ac es, whereb y slot 3 and slot 5 are used as x8 interfaces if slot 2 and slot 4 are empty . I Slot 1 is the pref erred slot f or the SAS/SA T A RAID controll ...

  • Fujitsu TX300 - page 77

    TX300 S6 Options Guide 77 Expansion cards and BBU Installing expansio n cards Ê Open the ser v er as described in the chapter "Preparation" on page 27 . Figure 49: Removing the slot cov er Ê Open the slot loc king bar in the direction of th e arrow (1). Ê Remov e the slot locking bar . Ê Remov e the slot cover (2). V CA UTION! K eep t ...

  • Fujitsu TX300 - page 78

    78 Options Guide TX300 S6 Installing expansion cards Expansion cards and BBU Figure 50: Installing an expansion card Ê Carefully press the new e xpansion card into the relev ant slot on the s ystem board (1). Ê Fit the clip onto the slot co v er so that the pin fits into the hole . Ê Push the clip under the metal nose (2) until it clic ks into p ...

  • Fujitsu TX300 - page 79

    TX300 S6 Options Guide 79 Expansion cards and BBU Installing a BBU 8.2 Installing a BBU V CA UTION! ● Do not connect the cable using e xcessiv e force, the connector is weak. ● F ollow the saf ety instructions in the chapter "Saf ety instructions" on page 19 . The Battery Bac kup Unit (BBU) bac ks up the memor y contents of the SAS/SA ...

  • Fujitsu TX300 - page 80

    80 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU The BBU carrier plate can accommodate up to three BBUs . Figure 52: P osition of used holes on the BBU carr ier plate First installe d BBU: use the b l ue marked holes to in stall the BBU . Second installed BB U: use the yello w marked holes to ins tall the BBU . Third installed BBU ...

  • Fujitsu TX300 - page 81

    TX300 S6 Options Guide 81 Expansion cards and BBU Installing a BBU Figure 53: Fasteni ng BBUs onto the BBU carr ier plate Ê F asten each BBU onto the BBU carri er plate in the specif ied order using the three screws included in the B BU kit. 햳 햴 햲 ...

  • Fujitsu TX300 - page 82

    82 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU Figure 54: Connecting the cable to the BBU Ê Connect the BBU cab les to the BBUs. V CA UTION! Make s ure that connector side A (one pin row) is f acing the BBU . If connector side B (two pin ro ws) is fac ing the BBU , you risk shor t- circu its. B A ...

  • Fujitsu TX300 - page 83

    TX300 S6 Options Guide 83 Expansion cards and BBU Installing a BBU Figure 55: Inser ting the BBU carr ier plate Ê Inser t the BBU carrier plate in the recesses of the drive cage (see circles). ...

  • Fujitsu TX300 - page 84

    84 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU Figure 56: F astening the BBU carrier plate Ê Close the BBU carrier plate at the top onto the drive cage . Ê F asten the BBU carrier plate to the drive cage using the M3 x 6 mm screw (see circ le). ...

  • Fujitsu TX300 - page 85

    TX300 S6 Options Guide 85 Expansion cards and BBU Installing a BBU Figure 57: Opening the cable cov er Ê Loosen the knurled screw on the cab le cov er (1) and push the cable cov er in direction of the arrow (2) until the guide releases (see circle). Figure 58: Removing the cable cover Ê Open the cable c ov er and pull it out of the guide (see cir ...

  • Fujitsu TX300 - page 86

    86 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU Figure 59: Routing the fi rst and second B BU cable Ê Route the first and the second BB U cabl e through the cab le guides as shown (1 + 2). Ê Connect the cables to the e xpansion cards (3). 햲 햳 햴 ...

  • Fujitsu TX300 - page 87

    TX300 S6 Options Guide 87 Expansion cards and BBU Installing a BBU Figure 60: Removing t he vol tage conv er ter holder T o route the third BBU cab le, the v oltage conv er ter holder must be remov ed: Ê Remov e the power cab l e (1). Ê Remov e the two screws (2). Ê Push the v oltage con verter holder in the direction of the arrow and remov e it ...

  • Fujitsu TX300 - page 88

    88 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU Figure 61: Threading the third BBU cab le through the cable opening Ê Thread the third BBU cab le through the opening belonging to the v oltage conv er ter holder (see circle). Ê Route the third BBU cable between the secondary processor sock et and the memory slots. ...

  • Fujitsu TX300 - page 89

    TX300 S6 Options Guide 89 Expansion cards and BBU Installing a BBU Figure 62: Reinser ting the v oltage conv er ter holder Ê Reinser t the voltage c onverter holder in the housing and push it in the direction of the arrows. Make s ure that the two guides (see circles) of the holder engage in the brac kets on the housing bottom positioned under the ...

  • Fujitsu TX300 - page 90

    90 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU Figure 63: Securing the v oltage con verter holder Ê Secure the voltage con ver ter holder with the two scre ws (1). Ê Reconnect the power cab le (2). 1 0 0 ...

  • Fujitsu TX300 - page 91

    TX300 S6 Options Guide 91 Expansion cards and BBU Installing a BBU Figure 64: Inser ting and fastening the cable cov er Ê Inser t the cable cov er in the recesses. Ê Close the cab le cov er at the top. Ê Make s ure that the third guide engages in the recess of the cab le guide (see circle ). Ê Secure the cab le cov er with the knurled screw . ? ...

  • Fujitsu TX300 - page 92

    92 Options Guide TX300 S6 Installing a BBU Expansion cards and BBU ...

  • Fujitsu TX300 - page 93

    TX300 S6 Options Guide 93 9 Fur ther op tions V CA UTION! F ollow the saf ety instructions in the chapter "Saf ety instructions" on page 19 . 9.1 TPM The ser ver can be equipped with a TPM (T r usted Platform Module). Figure 65: TPM installation kit Ê Open the ser v er as described in the chapter "Preparation" on page 27 . Ê P ...

  • Fujitsu TX300 - page 94

    94 Options Guide TX300 S6 TPM Further options Figure 66: Inser ting the TPM spacer on the system board Ê Inser t the TPM spacer into the hole on the system board. ...

  • Fujitsu TX300 - page 95

    TX300 S6 Options Guide 95 Further options TPM Figure 67: Securing the TPM Ê Inser t the TPM on the system board (1). Ê F asten the TPM with the special screw f or the TPM (2). Please use the TPM scre wdriver inser t bit to tighten the special scre w . I Do not f asten the scre w too tightly (torque v alue of 0.6 Nm). Ê Reinstall the hot-plug po ...

  • Fujitsu TX300 - page 96

    96 Options Guide TX300 S6 USB Flash Module (U FM) Further options 9.2 USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). Figure 68: UFM installation kit Ê Open the server as described in the chapter "Preparation" on page 27 . Figure 69: UFM - P osition on the system board 1 USB Flash Module (UFM) 3 UFM space ...

  • Fujitsu TX300 - page 97

    TX300 S6 Options Guide 97 Further options USB Flash Module (UFM) Figure 70: Connecting the UFM to the system board Ê Connect the USB Flash Modul e to the system board. The spacer must clic k into the hole on the system board. Ê Close the s er ver , connect it to the po wer outlet, and s witch it on as described in the chapter "Completion&quo ...

  • Fujitsu TX300 - page 98

    98 Options Guide TX300 S6 USB Flash Module (U FM) Further options ...

  • Fujitsu TX300 - page 99

    TX300 S6 Options Guide 99 10 Con version fr om a floors tand model to a rac k model V CA UTION! F ollow the saf ety instructions in the chapter "Saf ety instructions" on page 19 . Ê Open the ser v er and remov e the front c ov er as descr ibed in the chapter "Preparation" on page 27 . I The front cov er is no longer required. ? ...

  • Fujitsu TX300 - page 100

    100 Options Guide TX300 S6 Con version from a floorstand model to a rack model Ê If necessary , lay the server on its right-hand side. Get a second person to help y ou do this. The server can w eigh around 25 - 40 kg (depending on the configur ation). Make s ure that the ser ver f eet protr ude ov er the table edge. Figure 72: Removing the server ...

  • Fujitsu TX300 - page 101

    TX300 S6 Options Guide 101 Conversion from a f loorstand mo del to a rack model Ê Slide the f oot mounting rail bac k ward (2) until th e hooks (a) disengage. Ê Remov e the foot mounting rail (3). I The f oot mounting rail is no longer required. I The drive cage f or the accessible drives is c onstructed in such a wa y that the accessib le driv e ...

  • Fujitsu TX300 - page 102

    102 Options Guide TX300 S6 Con version from a floorstand model to a rack model Ê T ur n the dummy co vers remov ed beforehand through 90° to the left. Ê Install the drives and empty cov ers in the drive cage. Ê Reestabl ish all connections to the drives . Ê Attach the rac k front c ov er as descr ibed in the section "Attaching the rac k f ...

  • Fujitsu TX300 - page 103

    TX300 S6 Options Guide 103 Conversion from a f loorstand mo del to a rack model Figure 76: Fasteni ng the rail adapter ( shown rail adapter left) Ê F asten the two screws of the rai l adapter . Figure 77: Attaching labels Ê Attach the Fujitsu label and the P RIMERGY logo and model label to the rac k front side. Ê Install the rac k model in the r ...

  • Fujitsu TX300 - page 104

    104 Options Guide TX300 S6 Con version from a floorstand model to a rack model T o enable the rac k model to be shown correctly in ServerV iew Management user interf aces, proceed as f ollows: Ê Boot the system from the Server Vie w Suite D VD1. The ServerVie w Installation Manager is sta r ted. Ê In the first window , select your pref erred GUI ...

  • Fujitsu TX300 - page 105

    TX300 S6 Options Guide 105 11 Completion V CA UTION! F ollow the saf ety instructions in the chapter "Saf ety instructions" on page 19 . 11.1 Installing t he fan car rier Figure 78: Installing the fan carrier Ê Inser t the fan carrier in the ser ver (1). Ê Push the f an carrier in the direction of the arrow (2). V CA UTION! Ensure that ...

  • Fujitsu TX300 - page 106

    106 Options Guide TX300 S6 Installing the fan carrier Completion Figure 79: Connecting the po wer cable Ê F asten the fan carrier with thethree knurled screws (1). Ê Connect the pow er cab le to the fa n backplane (2). Ê Secure the pow er cable with the c abl e clamp (3). 1 2 0 0 0 ...

  • Fujitsu TX300 - page 107

    TX300 S6 Options Guide 107 Completion Floorstand mo del 11.2 Floorsta nd model 11.2.1 Mounting the server feet Figure 80: Mounting the ser v er feet Ê If required, reinstall the server f eet. T o do this, you need to fasten f our M3 x 6 mm screws to each of the server feet (s ee circles). ...

  • Fujitsu TX300 - page 108

    108 Options Guide TX300 S6 Floorstand model Completion 11.2.2 Attaching the fr o nt cover Reattach the front cov er after installing/remo ving accessible driv es. Figure 81: Attaching the front cov er Ê Hook the front cov er in place at the top (see circles). Ê Press the front cov er against the housing in the direction of the arrow . Figure 82: ...

  • Fujitsu TX300 - page 109

    TX300 S6 Options Guide 109 Completion Floorstand mo del Figure 83: Attaching the HDD co ver Ê Hook the drive co ver in place at the top and press it against the housing in the direction of the arrow (1). Ê Hook the HDD cover in place at the bottom and press it against the housing in the direction of the arrow ( 2). 햲 햳 ...

  • Fujitsu TX300 - page 110

    110 Options Guide TX300 S6 Floorstand model Completion 11.2.3 Closing t he ser ver I The left side co ver c loses easily when the server is in the horiz ontal position. Ê La y the server on its right side. Ask a second person to help y ou do this.The ser ve r can weigh up to 25-40 kg depending on its configur ation. Ensure that the f eet project o ...

  • Fujitsu TX300 - page 111

    TX300 S6 Options Guide 111 Completion Rack model 11.3 Rac k model 11.3.1 Attaching the rac k front co ver Reattach the rac k front cov er after implementing the f ollowi ng routines: – Installing/remo v ing accessib le drives – Conv ersion from a floorstand model to a rack model Figure 85: Attaching the rac k front cover Ê Attach the rac k fro ...

  • Fujitsu TX300 - page 112

    112 Options Guide TX300 S6 Rack model Completion 11.3.2 Closing t he ser ver Ê Pull the loc king lev er as far as it wi ll go and inser t the top cov er (see also figure 84 on page 110 ). Ê Push the top cov er against the housing and push down the loc king lev er at the same time. Closing the loc king le ver pushes the top co v er f orward and th ...

  • Fujitsu TX300 - page 113

    TX300 S6 Options Guide 113 Completion Rack model Figure 87: Inser ting t he ser ver (b) Ê Extend the telescopic r ails completely to the front (1). I They m us t click into place so that the y c an no longer be mo v ed. Ê Low er the ser ver from abo ve onto the projec ting telescopic rail s (2), (3). As you do thi s, the loc k ing bar (4) engages ...

  • Fujitsu TX300 - page 114

    114 Options Guide TX300 S6 Rack model Completion ...

  • Fujitsu TX300 - page 115

    TX300 S6 Options Guide 115 12 Appendix 12.1 Cab ling Y ou will find suggestions f or cabl ing on the ne xt pages. ...

  • Fujitsu TX300 - page 116

    116 Options Guide TX300 S6 Cabling Appendix Figure 88: Ser ver with 3.5-inch SAS HDDs and 3.5-inch SAS HDD e xtension bo x Legend: Power SAS/ SATA USB / VGA Data COM 1 COM 2 USB USB VGA CPU 1 LAN1 Slot 7 Operation panel A3C40097567 On/Off-SW Stdby-Power-LED HD-Activity- LED Reset and NMI Identify LED SAS – HDD 1“ SAS- Bpl 6 x 3 ,5“ A3C4007145 ...

  • Fujitsu TX300 - page 117

    TX300 S6 Options Guide 117 Appendix Cabling Figure 89: Server with 3.5-inch SA S HDDs and SAS back up Legend: Power SAS/ SATA USB / VGA Data COM 1 COM 2 USB USB VGA CPU 1 LAN1 Slot 7 Operation panel A3C40097567 On/Off-SW Stdby-Power-LED HD-Activity- LED Reset and NMI Identify LED CD-Rom / DVD slimline SAS- Bpl 6 x 3 ,5“ A3C40071451 SAS-HD 1“ SA ...

  • Fujitsu TX300 - page 118

    118 Options Guide TX300 S6 Cabling Appendix Figure 90: Server with 3.5-inch SA S HDDs and USB bac kup Legend: Power SAS/ SATA USB / VGA Data COM 1 COM 2 USB USB VGA CPU 1 LAN1 Slot 7 Operation panel A3C40097567 On/Off-SW Stdby-Power-LED HD-Activity- LED Reset and NMI Identify LED SAS – HDD 1“ SAS- Bpl 6 x 3 ,5“ A3C40071451 SAS-HD 1“ SAS-HD ...

  • Fujitsu TX300 - page 119

    TX300 S6 Options Guide 119 Appendix Cabling Figure 91: Ser ver with 2.5-inch SA S HDDs and 2.5-inch HDD e xtension box Legend: Power SAS/ SATA USB / VGA Data COM 1 COM 2 USB USB VGA CPU 1 LAN1 Slot 7 Operation panel A3C40097567 On/Off-SW Stdby-Power-LED HD-Activity- LED Reset and NMI Identify LED CD-Rom / DVD slimline SAS- Bpl 1 2 x 2,5 “ A3C4011 ...

  • Fujitsu TX300 - page 120

    120 Options Guide TX300 S6 Cabling Appendix Figure 92: Server with 2.5-inch SA S HDDs ( onboard SAS) and 2. 5-inch HDD e xtension bo x Legend: Power SAS/ SATA USB / VGA Data COM 1 COM 2 USB USB VGA CPU 1 LAN1 Slot 7 Operation panel A3C40097567 On/Off-SW Stdby-Power-LED HD-Activity- LED Reset and NMI Identify LED CD-Rom / DVD slimline SAS-HD 1“ SA ...

  • Fujitsu TX300 - page 121

    TX300 S6 Options Guide 121 Inde x A accessib le dr iv es attach ing Easy Click rails 58 detaching EasyClic k rails 57 D VD burner 14 DV D d r i v e 14 equipping ba ys 54 , 55 install ing Multiba y 1 64 magnetic tape driv e 14 removing dummy co ver 56 ServerVie w Local Service Displa y 14 appendix 115 B Battery Backup Unit 79 BBU 15 installing 79 C ...

  • Fujitsu TX300 - page 122

    122 Options Guide TX300 S6 Index installing LSP 60 Multiba y 2 68 installi ng 70 N notational con ventions 16 R rac k front cov er attaching 111 removing 34 rac k model opening 32 removing r ack front co ver 34 removing dumm y cov er 56 S SAS/SA T A RAID controll er BBU 79 ser ver closi ng 110 opening 28 , 32 server f eet mounting 107 removing 31 S ...

Manufacturer Fujitsu Category Server

Documents that we receive from a manufacturer of a Fujitsu TX300 can be divided into several groups. They are, among others:
- Fujitsu technical drawings
- TX300 manuals
- Fujitsu product data sheets
- information booklets
- or energy labels Fujitsu TX300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fujitsu TX300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fujitsu TX300, service manual, brief instructions and user manuals Fujitsu TX300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fujitsu TX300.

Similar manuals

A complete manual for the device Fujitsu TX300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fujitsu TX300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fujitsu TX300.

A complete Fujitsu manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fujitsu TX300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fujitsu TX300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fujitsu TX300, that we can find in the current document
3. Tips how to use the basic functions of the device Fujitsu TX300 - which should help us in our first steps of using Fujitsu TX300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fujitsu TX300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fujitsu TX300 in a specific country, if it was not possible to solve the problem on our own.