Manual Anritsu CMA 5000 - UTA

14 pages 1.44 mb
Download

Go to site of 14

Summary
  • Anritsu CMA 5000 - UTA - page 1

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 1 of 14 CMA 5000 - UTA SPECIFICATIONS Universal Transport Anal ysis Mod ule / SDH/S ONE T Applicat ion Content • The perfect to ol for testin g SDH & SON ET core net w orks up to 10 Gbps • Testing APS switch time reactio n of the net work w ...

  • Anritsu CMA 5000 - UTA - page 2

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 2 of 14 Key Feat ures Key Applications • • • • SDH/SONET interfa ces up to 10 Gbp s • • • • Pluggable XFP & S FP – 1310 nm / 1550 nm • • • • Generates and analyze s SONET/ SDH frames dow n to the tributary level (DS1 / ...

  • Anritsu CMA 5000 - UTA - page 3

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 3 of 14 Testing APS switch time r eaction of the net work w ith 125 µs resolution Due to the lar ge amount of inf ormation bein g transferred o ver S ynchronous Optical Net work (SON ET/SDH), it is extremel y important to en sure that the tr anspo ...

  • Anritsu CMA 5000 - UTA - page 4

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 4 of 14 Auto-discover y of the sig nal structure When perfor ming tests in the field, it is so metimes dif ficult to co nfigure the test equip ment a s the signal to b e analyzed is not always kno wn: is the signal co ncatenated, what the fra me ma ...

  • Anritsu CMA 5000 - UTA - page 5

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 5 of 14 Fast and profe ssional rep orts Creating profes sional repor t has never been so easy with the UTA app lication. After stop ping a measure ment, the rep ort is j ust one click away: p roduce, save, print rep orts dir ectly from the app lica ...

  • Anritsu CMA 5000 - UTA - page 6

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 6 of 14 Specifications Notes 1 The XFP/SFP interfa ces of the UTA module meet the requ irements stated in the MSA stand ard 2 Requires X FP/SFP that must be o rdered separately (see the orderin g guide) Interfaces and Signal Specifications Signal P ...

  • Anritsu CMA 5000 - UTA - page 7

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 7 of 14 DCC Signals The UTA-SDH/SON ET application supports the drop and insert of DC C channels from SON ET/SDH • D1-D3: 192 Kb/s • D4-D12: 576 Kb/s SONET Mappings ...

  • Anritsu CMA 5000 - UTA - page 8

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 8 of 14 SDH Mappings Test Pattern PRBS Patterns • PRBS: 2 9 -1, 2 11 -1, 2 15 -1, 2 20 -1, QR SS, 2 23 -1, 2 29 -1, 2 31 -1 inverted and non-inver ted Word Patterns • All “1” pattern, all “0” pattern, altern ative “01” pattern, “1 ...

  • Anritsu CMA 5000 - UTA - page 9

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 9 of 14 Error Addition SONET/DSn • A1/A2, B1, B2, R EI-L, B3, REI-P, V5, R EI-V, FA W (FAS), SFA W, FPS, MAW, Parity P, Parity CP, F-bit, M- bit, FEBE, CRC -6, PRBS, Word, transmission er rors SDH/PDH • A1/A2, B1, B2, MS-RE I, B3, LP-B 3, HP-RE ...

  • Anritsu CMA 5000 - UTA - page 10

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 10 of 14 A larm A ddition SONET/DSn • LOS, LOF, SEF, TIM -S, AIS-L, RD I-L, AIS-P, LO P-P, TIM-P, PLM -P, UN EQ-P, RDI-P, LOM-V, AIS-V, LOP- V, PLM-V, U NEQ-V, RDI-V, TIM-V, RFI-V, LO MF, LSF, OOF, RAI, IDLE, LSS, LPS, A IS SDH/PDH • LOS, LOF, ...

  • Anritsu CMA 5000 - UTA - page 11

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 11 of 14 Path Ana l ys is Signal Qualification • Power meter • Frequency meter Errors Analysis • SONET/DSn A1/A2, B1, B2, R EI-L, B3, REI-P, V5, R EI-V, FA W (FAS), SFA W, FPS, MAW, Parity P, Parity CP, F-bit, M- bit, FEBE, CRC -6, PRBS, Word ...

  • Anritsu CMA 5000 - UTA - page 12

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 12 of 14 Performance A nalysis • Direct graphical pre sentation of pe rformance and availability confor mance test resul t • Automatic calculation o f acceptan ce thresholds a ccording to ITU-T r ecommandations, such as M.2100 , M.2101.1 and M ...

  • Anritsu CMA 5000 - UTA - page 13

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 13 of 14 Ordering Information Note 1: For bes t performa nce, the C MA5000 plat form must have 512M RA M when using UT A with more than on e application. Note 2: All the 10G /11G ap plications ar e field upgra deable. For upgrades w ith referenc e ...

  • Anritsu CMA 5000 - UTA - page 14

    ISO 9001:2000 certif ied. ICMA5KU TASTM64-SPEC05-08 06-A4. ©2008 Anritsu. All Rights Re served. Page 14 of 14 A nritsu Corporation 5-1-1 Onna, Atsugi- shi, Kanagaw a, 243-8555 Japan Phone: +81-46-223 -1111 Fax: +81-46 -296-1264 • U.S.A. A nritsu Compan y 1155 East Collins Blvd. , Richardson , TX 75081, U.S.A. Toll Free: 1-800-ANR ITSU (267-487 8 ...

Manufacturer Anritsu Category Dishwasher

Documents that we receive from a manufacturer of a Anritsu CMA 5000 - UTA can be divided into several groups. They are, among others:
- Anritsu technical drawings
- CMA 5000 - UTA manuals
- Anritsu product data sheets
- information booklets
- or energy labels Anritsu CMA 5000 - UTA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Anritsu CMA 5000 - UTA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Anritsu CMA 5000 - UTA, service manual, brief instructions and user manuals Anritsu CMA 5000 - UTA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Anritsu CMA 5000 - UTA.

Similar manuals

A complete manual for the device Anritsu CMA 5000 - UTA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Anritsu CMA 5000 - UTA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Anritsu CMA 5000 - UTA.

A complete Anritsu manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Anritsu CMA 5000 - UTA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Anritsu CMA 5000 - UTA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Anritsu CMA 5000 - UTA, that we can find in the current document
3. Tips how to use the basic functions of the device Anritsu CMA 5000 - UTA - which should help us in our first steps of using Anritsu CMA 5000 - UTA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Anritsu CMA 5000 - UTA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Anritsu CMA 5000 - UTA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Anritsu CMA 5000 - UTA?

Use the form below

If you did not solve your problem by using a manual Anritsu CMA 5000 - UTA, ask a question using the form below. If a user had a similar problem with Anritsu CMA 5000 - UTA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)