Manual Desa CGDV32pR

44 pages 2.25 mb
Download

Go to site of 44

Summary
  • Desa CGDV32pR - page 1

    DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL For more information, visit www .desatech.com NATURAL GAS “TUDOR” MODELS (V)T32N-A SERIES AND CGDV32NR PROPANE/LP GAS “TUDOR” MODELS (V)T32P-A SERIES AND CGDV32PR W ARNING: If the information in this manual is not fol- lowed exactly , a re or explosion may result caus ...

  • Desa CGDV32pR - page 2

    www .desatech.com 1 16646-01D 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes......................................................... 4 Product Features ................................................. 4 ...

  • Desa CGDV32pR - page 3

    www .desatech.com 1 16646-01D 3 Ca rb on M o no xid e P oi son in g: Ear ly s igns of ca rbo n mono xide poisoni ng resem ble the u, with he ad - ache s, dizzi ness or nause a. If you have the se signs, the replace may not be working properly . Get fr esh air at once! Have rep lac e servi ced. Some peop le are more af fect ed by carbo n mo ...

  • Desa CGDV32pR - page 4

    www .desatech.com 1 16646-01D 4 SAFETY INFORMA TION Continued 9. Do not use this replace to cook food or burn paper or other objects. 10. This appl ian ce, whe n ins tal led , mu st b e ele ctr i - call y gro unde d in accor danc e wit h loc al codes or , in the absence of local codes, with the Nati onal Electr ical Code, ANS I/NF P A 70 or the ...

  • Desa CGDV32pR - page 5

    www .desatech.com 1 16646-01D 5 PRE-INST ALLA TION PREP ARA TION LOCA TION AND SP ACE REQUIREMENTS Determine the safest and most efcient location for your DESA direct-vent replace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ...

  • Desa CGDV32pR - page 6

    www .desatech.com 1 16646-01D 6 PRE-INST ALLA TION PREP ARA TION Continued NOTICE: This replace is in - ten ded for u se as sup ple men tal he at. Us e t hi s re pla c e al ong wi t h you r pri mar y he ati ng syste m. Do not inst all this rep lac e as y our pr im ar y h ea t so ur ce . If yo u ha ve a cen tra l heati ng syste m, you may r ...

  • Desa CGDV32pR - page 7

    www .desatech.com 1 16646-01D 7 Fixed Closed Op en ab le Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum] B = clearance to w ...

  • Desa CGDV32pR - page 8

    www .desatech.com 1 16646-01D 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- t i o n s c o m p l e t e l y b e f o r e a t - tempting installation. Thes e m ode ls are test ed and appr ove d f or use with DESA (direct-vent) pipe components and terminations. Th e v en ti ng syst em mu st te rm in ate on th e o ut si de of the str ...

  • Desa CGDV32pR - page 9

    www .desatech.com 1 16646-01D 9 INST ALLA TION PLANNING There are two basic types of direct-vent instal - lation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORT ANT : Horizontal square terminations require only inner portion of wall restop. Hori - zon tal i nsta lla tio ns us ing r ound term in ...

  • Desa CGDV32pR - page 10

    www .desatech.com 1 16646-01D 10 6. Nonco mbusti ble Exteri or Wal l: Posit ion the ho riz on ta l ve nt cap in the ce nte r o f th e 8 1 / 2 " ro und ho le a nd att ac h to th e ex te rio r w al l wi th fo ur sc re ws (s ee pa ge 10). Note : Th e fou r w oo d sc rew s pro vi de d sho ul d be rep la ce d wit h ap - pr op ria te fa st en er s f ...

  • Desa CGDV32pR - page 11

    www .desatech.com 1 16646-01D 1 1 Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind T ermination Apply Mastic to Outside Edge of Standoff Exterior W all with Vinyl Siding 10 3 / 4 " x 10 3 / 4 " Framed Opening Maintain 1" Minimum Air Space Around Outer ...

  • Desa CGDV32pR - page 12

    www .desatech.com 1 16646-01D 12 VENTING INST ALLA TION INSTR UCTIONS Continued V ertical (V) Required V ertical (V) V ertical Pipe Horizontal (H) *43 3 / 4 " min. None 30" max. 53 3 / 4 " min. 1 ft. 48" max. 65 3 / 4 " min. 2 ft. 60" max. 77 3 / 4 " min. 3 ft. 84" max. 89 3 / 4 " min. 4 ft. 20' max ...

  • Desa CGDV32pR - page 13

    www .desatech.com 1 16646-01D 13 HORIZONT AL SYSTEM INST ALLA TION USING TWO 90° ELBOWS The following congurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. VENTING INST ALLA TION INSTR UCTIONS Continued Figure 17 - Horizontal T ermination Conguration for V enting Using T wo 90° Elbows V enti ...

  • Desa CGDV32pR - page 14

    www .desatech.com 1 16646-01D 14 INS TALL ATI ON F OR VERTICAL TER MINA TIO N Note: V ertical restrict or must be installe d in all ve rt ic al i ns ta ll at io ns . 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct the venting system, consi der an of fset (se e Figure 19) to avoi ...

  • Desa CGDV32pR - page 15

    www .desatech.com 1 16646-01D 15 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 8. Note: Y ou must increase vent height for steep roof pitches. Nearby trees, adjoining rooi nes, ste ep pitche d roofs an d other sim ilar factors may cause poor draft or d ...

  • Desa CGDV32pR - page 16

    www .desatech.com 1 16646-01D 16 VENTING INST ALLA TION INSTRUCTIONS Continued V ertical Venting V = 40' max. Figu re 2 4 - V ert ical V enting Con gur atio n Wit h No Hor izon tal Run (V ertica l Ro und High Wi nd T ermi nati on S hown ) Note: Install restrictor into inner collar of replace as shown. 45° Elbow HIGH AL TITUDE INST ALLA ...

  • Desa CGDV32pR - page 17

    www .desatech.com 1 16646-01D 17 VENTING INST ALLA TION INSTRUCTIONS Continued Number Description VKR-58 Roof V ent Kit, Galvanized (Includes: 45° Elbow , 7"-12" Adjustable Pipe, Flue Restrictor , V ertical High Wind T ermination, 2' Pipe, 4' Pipe, W all Firestop, Storm Collar , Roof Flashing [0/12 - 6/12], 26 Screws) VKC-58 Co ...

  • Desa CGDV32pR - page 18

    www .desatech.com 1 16646-01D 18 3. Place the blowe r aga inst the lowe r rea r wal l of the rebo x out er wr appe r wit h the e xhau st po rt dire cted upwa rd. The blow er will t i nsid e the back opening and b e held in positio n agains t the back wall by the magne ts (see Figur e 26, page 17) . 4. Be certain that all wire terminals are se ...

  • Desa CGDV32pR - page 19

    www .desatech.com 1 16646-01D 19 3. Place the blowe r aga inst the lowe r rea r wal l of the rebo x out er wr appe r wit h the e xhau st po rt dir ect ed up war d and the ther mod isc posi tio ned up near the repla ce bott om. The thermo disc must be orient ed near the rep lace botto m as show n in Fig ure 29, in order to sense temp era - ...

  • Desa CGDV32pR - page 20

    www .desatech.com 1 16646-01D 20 INST ALLING GAS PIPING TO FIREPLACE LOCA TION W ARNING: A qualified service person must connect replace to gas supply . Follow all local codes. CAUTION: For propane/LP uni ts, nev er conn ect re plac e di - rectly to the propane/LP supply . This heater requires an external regulator (not supplied). Install the ...

  • Desa CGDV32pR - page 21

    www .desatech.com 1 16646-01D 21 Figure 32 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.5" W .C. to 10.5" W .C. Pressure) Propane/LP From External Regulator (1 1" W .C. ...

  • Desa CGDV32pR - page 22

    www .desatech.com 1 16646-01D 22 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Cl os e eq ui pm en t sh ut of f v al ve ( se e Fi gu re 3 4) . 2. Pr ess ur iz e sup pl y pip in g sy ste m by ei th er opening propa ne/LP sup pl y tan k val ve fo r propane/LP gas replace or opening main gas valve located on or near gas meter for nat ...

  • Desa CGDV32pR - page 23

    www .desatech.com 1 16646-01D 23 FIREPLACE INST ALLA TION Continued INST ALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL HRC100 AND HRC200 SERIES NOTICE: Use only alkaline bat - teries (not included). Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left. 2. Uns cr ew the swi tch b rac ke t. Lean b rac ke t fo ...

  • Desa CGDV32pR - page 24

    www .desatech.com 1 16646-01D 24 Removing Glass Door If replacement of glass is necessary , the entire assembly , glass and frame, must be replaced. If gla ss is b roke n, we ar gl oves and t ape th e rem ain ing fragments onto the frame. 1. Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/ro ...

  • Desa CGDV32pR - page 25

    www .desatech.com 1 16646-01D 25 9. Follow instructions below to install logs, lava rock and ember material. 10. Clo se g la ss do or , loc k l at ch es o n t op an d bot to m of doo r and re plac e scree n (see steps 5 and 6 of Remo ving Gl ass Door , page 24) . 1 1. Close top and bottom louvers. Figure 44 - Installing Side Brick Panels Left Side ...

  • Desa CGDV32pR - page 26

    www .desatech.com 1 16646-01D 26 5 6 Figu re 4 9 - Ins tall ing Logs No. 5 a nd N o. 6 FIREPLACE INST ALLA TION Continued 6. Place log #6 (left log) onto two pins on the left side of back and front log. See Figure 49. 7. Place lava rock along sides and front of rebox bottom in areas that are visible only . It is not necessary to use all of the l ...

  • Desa CGDV32pR - page 27

    www .desatech.com 1 16646-01D 27 LIGHTING INSTRUCTIONS 1. ST OP! Re ad the safe ty inf orma tion on page 26, column 2. 2. Open lower louver panel. 3. T urn off all electric power to the fire- place. 4. Push in gas control knob slightly and turn clockwise to OFF . 5. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near th ...

  • Desa CGDV32pR - page 28

    www .desatech.com 1 16646-01D 28 IMPORT ANT : Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery . O F F P I L O T L O I H ON OFF REMOTE ON OFF O N Blower Control Knob (Optional Accessory) V ariable Control Knob Selector Switch in Remote Position Gas Control Knob in ON Position Figur ...

  • Desa CGDV32pR - page 29

    www .desatech.com 1 16646-01D 29 Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the r eplace, the receiver ON/OFF/REMOTE switch should be in the OFF position. Auto Shutoff Feature 1. If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centi- ...

  • Desa CGDV32pR - page 30

    www .desatech.com 1 16646-01D 30 Fi gu re 56 - T ypical Flame Pattern If you pilot assembly does not meet these re - quirements: • turn replace of f (see T o T urn Off Gas to Ap- pliance , page 28) • see T roubleshooting , page 32 BURNER FLAME P A TTERN Burn er a mes wi ll be st eady ; not l ifti ng or o atin g. Flame patterns will be ...

  • Desa CGDV32pR - page 31

    www .desatech.com 1 16646-01D 31 CLEANING AND MAINTENANCE Continued Use only the tempered glass door replacement inte nded for this re plac e (see R epla ceme nt Parts , page 36 for det ail on orderi ng) . No subs titu tion s ma y be m ade . See Re mo vin g/ Re pla ci n g G la ss D oo r , page 23 for ins truc tion s fo r re plac ing glas s do or ...

  • Desa CGDV32pR - page 32

    www .desatech.com 1 16646-01D 32 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualied service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PRO ...

  • Desa CGDV32pR - page 33

    www .desatech.com 1 16646-01D 33 OBSERVED PROBLEM Pilot lights but ame goes out when control knob is released Burner does not light after pilot is lit Delayed ignition burner Burner backring during com - bustion Slig ht smoke or odor during init ial operation POSSIBLE CAUSE 1. Gas control knob not fully pressed in 2. Gas control knob not pres ...

  • Desa CGDV32pR - page 34

    www .desatech.com 1 16646-01D 34 OBSERVED PROBLEM Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ ticking noise just after burners are lit or shut off Remote does not function Fireplace shuts off in use POSSIBLE CAUSE 1. T urning gas control knob to HI posi tio n w he n b urn er is cold 2. Air in gas ...

  • Desa CGDV32pR - page 35

    www .desatech.com 1 16646-01D 35 POSSIBLE CAUSE 1 . Gas leak. See W arning statement above 1 . Gas leak. See W arning statement above 2. Control valve defective 1 . Gas leak. See W arning statement above 1. Improper log placement 2. A i r h o l e s a t b u r n e r i n l e t blocked 3. Burner ame holes blocked 4. Impr oper v enti ng or exc essi v ...

  • Desa CGDV32pR - page 36

    www .desatech.com 1 16646-01D 36 SPECIFICA TIONS (V)T32N-A Series and CGDV32NR • Rating: 12,000/18,000 Btu/Hr • T ype Gas: Natural Gas Only • Ignition: Piezo • Manifold Pressure: 3.5" W .C. • Minimum Inlet Gas Pressure (W .C.): 5.5" • Dimensions (H x W x D) (Firebox only - Does not include nailing flanges or standoffs): 32 1 / ...

  • Desa CGDV32pR - page 37

    www .desatech.com 1 16646-01D 37 ACCESSORIES NOTICE: All accessories may not be available for all replace models. Pu rc has e t he se re pl ac e a cc ess or ie s f rom yo ur lo ca l reta iler . If th ey can not supp ly the se acce ssor ies , call DESA ’ s Sal es Depart ment at 1-866-6 72-6 040. for inf orma tion . Y ou can also writ e to th ...

  • Desa CGDV32pR - page 38

    www .desatech.com 1 16646-01D 38 6 7 21 18 19 10 13 2 12 20 8 22-2 22-6 22-4 22-5 22-3 22-1 1 14 9 1 1 17 15 4 16 5 16 3 ILL USTRA TED P ARTS BREAKDOWN MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V)T32NRB-A, (V)T32P-A, (V)T32PB-A, (V)T32PR-A, (V)T32PRB-A, CGDV32NR AND CGDV32PR ...

  • Desa CGDV32pR - page 39

    www .desatech.com 1 16646-01D 39 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 36 of this manual. P ART NUMBER KEY NO. (V) T32N-A (V) T32P-A (V) T32NB-A (V) T32PB-A CGDV32NR CGDV32PR (V) T32NR-A (V) T32PR-A (V) T32NRB-A (V) T32PRB-A DESCR ...

  • Desa CGDV32pR - page 40

    www .desatech.com 1 16646-01D 40 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 1 1 17 19 ILL USTRA TED P ARTS BREAKDOWN BURNER ASSEMBL Y MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V)T32NRB-A, (V)T32P-A, (V)T32PB-A, (V)T32PR-A, (V)T32PRB-A, CGDV32NR AND CGDV32PR ...

  • Desa CGDV32pR - page 41

    www .desatech.com 1 16646-01D 41 KEY NO. P ART NO. DESCRIPTION QTY . 1 1 1 102 Screw #8-32 x 3/8 PPH Zinc 2 2 1 1 105 Screw #10 x 1/2 Zinc 9 3 1 1 179 Screw #10-24 x 1/4 Zinc 4 4 1 1237 Screw , T rilab M4 x 8 mm 1 5 14389 Millivolt V alve (Natural Gas) 1 14390 Millivolt V alve (Propane/LP Gas) 1 1 17370-01 Millivolt V alve (NG-High Altitude)) 1 6 1 ...

  • Desa CGDV32pR - page 42

    www .desatech.com 1 16646-01D 42 _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________ ...

  • Desa CGDV32pR - page 43

    www .desatech.com 1 16646-01D 43 _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________ ...

  • Desa CGDV32pR - page 44

    116646 01 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 1 16646-01 Rev . D 02/06 NOT A UPC LIMITED WARRANTY DIRECT -VENT FIREPLACE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of rst purchase, provided that the product has been properly insta ...

Manufacturer Desa Category Outdoor Fireplace

Documents that we receive from a manufacturer of a Desa CGDV32pR can be divided into several groups. They are, among others:
- Desa technical drawings
- CGDV32pR manuals
- Desa product data sheets
- information booklets
- or energy labels Desa CGDV32pR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa CGDV32pR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa CGDV32pR, service manual, brief instructions and user manuals Desa CGDV32pR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa CGDV32pR.

Similar manuals

A complete manual for the device Desa CGDV32pR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa CGDV32pR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa CGDV32pR.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa CGDV32pR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa CGDV32pR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa CGDV32pR, that we can find in the current document
3. Tips how to use the basic functions of the device Desa CGDV32pR - which should help us in our first steps of using Desa CGDV32pR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa CGDV32pR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa CGDV32pR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa CGDV32pR?

Use the form below

If you did not solve your problem by using a manual Desa CGDV32pR, ask a question using the form below. If a user had a similar problem with Desa CGDV32pR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)