    Manuf actur ed by DM Industries, Ltd . TM Delux e U- 130 ...

  • Vita Spa U -1 3 0 - page 2

    T ABLE OF CONTENTS Owner ’ s Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Impor tant Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Vita Spa U -1 3 0 - page 3

    This OWNER’S MANU AL has been designed to familiarize you with y our Spa operations and general maintenance . W e suggest that you take some time to carefully review it. Please keep this manual available f or reference . If you hav e any questions regarding your spa set-up , operation or mainte- nance , please contact DM T echnical Suppor t at th ...

  • Vita Spa U -1 3 0 - page 4

    —2 — IMPOR T ANT S AFETY INS TRUC TIONS WHEN INS T ALLING AND USING THIS ELEC TRIC AL EQUIPMENT , B ASIC S AFETY PREC A UTIONS SHOULD AL W A Y S BE FOLLO WED , INCLUDING THE FOLLO WING: 1. W ARNING : T o reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times. 2. DANGER! RISK OF AC CI ...

  • Vita Spa U -1 3 0 - page 5

    DO’S & DON’TS DO Make sure the spa is connected to a Ground F ault Circuit Interrupter (GFCI) protected circuit. This GFCI is required by the National Electrical Code (NEC) and is supplied with the unit. DO T est the water with your hand before ent ering the spa to be sure it is comfortable. DO Remember that wet sur faces can be slippery . ...

  • Vita Spa U -1 3 0 - page 6

    W ARNINGS Pr olonged immersion in water that is warmer than normal body temperature can r esult in a dangerous condition known as HYPO THERMIA. The causes, symptoms , and effects of hypothermia ma y be described as follows: Hypothermia occurs when the internal temperature of the body r eaches a level sev eral degrees abov e the normal body temperat ...

  • Vita Spa U -1 3 0 - page 7

    INS T ALLA TION INS TRUC TIONS Site Selection/P reparation The spa must be installed on a structurally strong , solid and reasonably level surface. The site should allow f or drainage awa y from the equipment compar tment in which the elec- trical components are housed . T ake into account the following when considering prospective sites: L OCAL CO ...

  • Vita Spa U -1 3 0 - page 8

    Spa Location 1 2 3 4 5 6 CLEARANCES CHECK THE FOLL OWING AREAS PRIOR TO SP A DELIVERY 1. STEPS - W e suggest no more than six without a landing. 2. TREE BRANCHES - Clearance for spa passage. 3. TIGHT CORNERS - Make sure there is space to maneuv er . 4. STORA GE SHEDS, DOG HOUSES, WOOD PILES - Remove out of the way . 5. GA TES: CLEARANCE FOR P ASSAG ...

  • Vita Spa U -1 3 0 - page 9

    WIRE Y OUR SP A PER ONE OF THE DIAGRAMS MOST SIMILAR TO Y OUR HOUSE P ANEL ALL WIRES FEEDING THE SP A ARE T O BE THE SAME GA UGE. GROUND WIRES ARE T O BE INSULA TED AS WELL. WHEN USING A GROUND ROD , THE GROUND WIRE T O THE ROD SHOULD BE #6 BARE C OPPER. ALL SP AS REQUIRE THE USE OF AN ISOLA TED GFCI PRO TECTED CIRCUIT . THE INST ALLA TION OF A DIS ...

  • Vita Spa U -1 3 0 - page 10

    C OMMON NEUTRAL GROUND BAR IN MAIN SEP AR A TE NEUTRAL & WEAK GROUND OR ROMEX WIRE USED TO FEED GFCI WITH UNDERSIZED GROUND WIRE —8 — ...

  • Vita Spa U -1 3 0 - page 11

    GFCI IN P ANEL WITH SEP AR A TE NEUTRAL AND SOLID GROUND T O P ANEL GFCI IN P ANEL WITH C OMMON NEUTRAL BAR AND/OR ROMEX WITH UNDERSIZED WIRE USED T O FEED DIS- C ONNECT . —9 — ...

  • Vita Spa U -1 3 0 - page 12

    GFCI MOUNTED IN P ANEL AND DISC ONNECT MOUNTED INSIDE T O C OMMON W ALL WITH MET AL STUDS OR WITH MET AL MOUNTING BO X. GFCI IN P ANEL WITH WEAK GROUND OR ROMEX WITH UNDER- SIZED GROUND WIRE USED T O FEED DISC ONNECT — 10 — ...

  • Vita Spa U -1 3 0 - page 13

    1. T he spa must be permanently con- nected (hardwired) to the power sup- ply . No extension cords or plug-type connections are to be used in con- junction with the operation of the spa. F ailure to supply pow er to the spa that is not in accordance with these instructions could create a potential health hazard and will v oid both the manufacturer ...

  • Vita Spa U -1 3 0 - page 14

    Getting Started: NO TE: F or best results, read each step carefully and en tirely before proceeding t o the nex t. FILL Y OUR SP A Wipe the interior of the spa with a damp , soft cloth to remov e any residue that may be on the sur face . F ill with a garden hose. As the spa is filling check in the equipment access area for an y leaks. On occasion, ...

  • Vita Spa U -1 3 0 - page 15

    CONTROLS & OPERA TING INS TRUC TIONS Note: For best results , read each step carefully and entirely bef ore proceeding to the next. TESTING THE GFCI The GFCI shuts off the electricity in a frac tion of a second if there is ashort anywhere in the system. It is rec- ommended that the GFCI be tested prior to each use . T est as follows: 1. Push th ...

  • Vita Spa U -1 3 0 - page 16

    D . Auto Heat Operation This equipment has includes a 2-speed pump for the primary pump. The low speed operates during filtr a- tion and heating cycles. Y our selec ted water temper ature will be maintained automatically 24 hours a day . The electronic thermostat will monitor your water t emperature at the top of each hour by cycling the low speed ...

  • Vita Spa U -1 3 0 - page 17

    J. Resetting Y our Spa Just like your computer at home , you spa electronics could get corrupted by electrical surges or spikes, or by low voltage . This could result in improper operation. Anytime there is reason to believe that y our system is not operating properly , please follow the f ollowing resetting procedur e: 1. T urn the power to the of ...

  • Vita Spa U -1 3 0 - page 18

    SP A MAINTENANCE Y our spa is manufactured with the highest quality and most durable materials available . A spa care and maintenance progr am is recommended to increase your comfort, main- tain the spa ’ s reliability and protec t your in vestment. 1) DRAINING Y OUR SP A Detergent residues from bathing suits as w ell as soap film from your body ...

  • Vita Spa U -1 3 0 - page 19

    3) FIL TER MAINTENANCE Maintenance is the most critical factor in keeping your spa water clean. T o clean the filter: NEVER RUN SP A WITHOUT FIL TER A. Remove the cartridge and spray it with a garden hose. It will be necessar y to rotate the car tridge while spra ying so as to thoroughly remove the debris lodged betw een the filter pleats. B. After ...

  • Vita Spa U -1 3 0 - page 20

    W A TER QU ALITY AND MAINTENANCE GENERAL GUIDELINES FOR W A TER QU ALIT Y MAINTENANCE Maintaining water quality within specific limits will enhance your enjoyment and prolong the life of the spa. Safe, comfor table and clean spa water is a fairly simple task to achiev e, but it does require regular attention because of the numer ous factors that ca ...

  • Vita Spa U -1 3 0 - page 21

    DIA GNOS TIC & TROUBLESHOOTING Resetting Y our Spa Just like your computer at home , you spa electronics could get corrupted b y elec trical surges and operate impr operly . If your spa system is not operating properly or sho ws any of the following messages , please reset it to see if the mal- function clears itself. T urn power off f or 15 fu ...

  • Vita Spa U -1 3 0 - page 22

    Maintenance Record Keep track of your water maint enance — 21 — ...

  • Vita Spa U -1 3 0 - page 23

    — 20 — Schemat ic U U 130 T erminal Block T ransformer Pressure S witch Heater Circuit Board ...

  • Vita Spa U -1 3 0 - page 24

    - 22 - LI M ITED W AR R ANT Y FOR E C O SP AS DM Industries, Ltd. 23 20 NW 1 4 7th Street, Miami, Florida 3305 4 WARR-ECO05-0117 DM Industries, Ltd., extends this limited warranty solely to the original Purchaser of any Eco Spa pur chased within the United States or Canada. 5 YEAR STRUCTUR AL SP A SHELL: DM Industries, Ltd., warrants its shells aga ...

  • Vita Spa U -1 3 0 - page 25

    © 2005 DM Industries Ltd 2320 NW 147th Street Miami, Florida 33054 PH 305-685-5739 ECODX-05-0517 ...

Manufacturer Vita Spa Category Hot Tub

Documents that we receive from a manufacturer of a Vita Spa U -1 3 0 can be divided into several groups. They are, among others:
- Vita Spa technical drawings
- U -1 3 0 manuals
- Vita Spa product data sheets
- information booklets
- or energy labels Vita Spa U -1 3 0
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vita Spa U -1 3 0.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vita Spa U -1 3 0, service manual, brief instructions and user manuals Vita Spa U -1 3 0. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vita Spa U -1 3 0.

A complete manual for the device Vita Spa U -1 3 0, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vita Spa U -1 3 0 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vita Spa U -1 3 0.

A complete Vita Spa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vita Spa U -1 3 0 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vita Spa U -1 3 0, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vita Spa U -1 3 0, that we can find in the current document
3. Tips how to use the basic functions of the device Vita Spa U -1 3 0 - which should help us in our first steps of using Vita Spa U -1 3 0
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vita Spa U -1 3 0
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vita Spa U -1 3 0 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vita Spa U -1 3 0?

Use the form below

If you did not solve your problem by using a manual Vita Spa U -1 3 0, ask a question using the form below. If a user had a similar problem with Vita Spa U -1 3 0 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)