Manual Cabletron Systems 9F426-03

14 pages 0.2 mb
Download

Go to site of 14

Summary
  • Cabletron Systems 9F426-03 - page 1

    9032058-01 SmartSwitch 9000 9F426-03 Local Management Appendix ...

  • Cabletron Systems 9F426-03 - page 2

    ...

  • Cabletron Systems 9F426-03 - page 3

    1 Appendix 9F426-03 Module Specific Inf ormation Intr oduction This appendix contains local management information that is specific to the 9F426-03 FDDI Switch Module. Module Interfaces The 9F426-03 FDDI Switch Module has 8 interfaces. T able 1 lists the identifying number , name, and description of each interface. T ab le 1. 9F426-03 FDDI Switch ...

  • Cabletron Systems 9F426-03 - page 4

    9F426-03 Module Specific Inf or mation 2 Use the numbers listed in T able 1 to configure the module’s default interface (see General Configuration Screen in the SmartSwitch 9000 Module Local Management User ’ s Guide ). ...

  • Cabletron Systems 9F426-03 - page 5

    3 9F426-03 Module Specific Inf or mation Ring Map Configuration Screen The Ring Map Configuration Screen (Figur e 1), contains configuration and connection information and displays the topology of the FDDI rings connected to the module. Figure 1. Ring Map Configuration Screen SmartSwitch 9000 Local Management Ring Map Configuration Module Name ...

  • Cabletron Systems 9F426-03 - page 6

    9F426-03 Module Specific Inf or mation 4 Ring Map Configuration Screen Fields The following information briefly explains each Ring Map Configuration Screen field. FDDI Address Displays the address of the module. The format of this addr ess (either MAC or Canonical) is determined by the value you select in the Address Mode field. MA C Count Di ...

  • Cabletron Systems 9F426-03 - page 7

    5 9F426-03 Module Specific Inf or mation The Ring Map The Ring Map shows a series of addresses in upstr eam/downstream or der . These addresses, which r epresent each FDDI device attached to the ring, ar e arranged on the screen to simulate the cir cular fashion of a ring. When first displayed, the station at the upper left corner of this map is ...

  • Cabletron Systems 9F426-03 - page 8

    9F426-03 Module Specific Inf or mation 6 Ring Map Node Screen The Ring Map Node Screen (Figur e 2), displays specific information for a selected FDDI node on the Ring Map. Figure 2. Ring Map Node Screen SmartSwitch 9000 Local Management Ring Map Node Module Name: 9F426-03 Firmware Revision: 01.04.10 Slot Number: 11 BOOTPROM Revision: 01.02.00 SEL ...

  • Cabletron Systems 9F426-03 - page 9

    7 9F426-03 Module Specific Inf or mation Ring Map Node Screen Fields The following information briefly explains each Ring Map Node Screen field. Address Displays the address of the selected node. Upstream Address Displays the address of the selected node’s near est upstream neighbor . Node Class Displays the class (NAS, DAS, DAC, SAS, or SAC) ...

  • Cabletron Systems 9F426-03 - page 10

    9F426-03 Module Specific Inf or mation 8 Switch Configuration Screen The Switch Configuration Screen (Figur e 3), displays parameters you can configure to make the switch operational. Figure 3. Switc h Configuration Screen SmartSwitch 9000 Local Management Switch Configuration Module Name: 9F426-03 Firmware Revision: 01.04.10 Slot Number: 9 BO ...

  • Cabletron Systems 9F426-03 - page 11

    9 9F426-03 Module Specific Inf or mation Switch Configuration Screen Fields The following information briefly explains each Switch Configuration Screen field. T ype of ST A (T oggle) Allows you to set the method that bridges use to decide which bridge is the controlling (Root) bridge when two or mor e bridges exist in parallel (Spanning T ree ...

  • Cabletron Systems 9F426-03 - page 12

    9F426-03 Module Specific Inf or mation 10 Full Duple x Configuration Screen The Full Duplex Configuration Screen (Figur e 4), allows you to specify transmit and receive settings for the module’s fr ont panel ports. Figure 4. Full Duple x Configuration Screen SmartSwitch 9000 Local Management Full Duplex Configuration Module Name: 9F426-03 Fir ...

  • Cabletron Systems 9F426-03 - page 13

    11 9F426-03 Module Specific Inf or mation Full Duplex Configuration Screen Fields The following information briefly explains each Full Duplex Configuration Screen field. OPERA TION MODE (T oggle) Lets you determine whether the specified port will transmit and receive data separately or simultaneously . Y ou can set this field to one of the f ...

  • Cabletron Systems 9F426-03 - page 14

    9F426-03 Module Specific Inf or mation 12 ...

Manufacturer Cabletron Systems Category Switch

Documents that we receive from a manufacturer of a Cabletron Systems 9F426-03 can be divided into several groups. They are, among others:
- Cabletron Systems technical drawings
- 9F426-03 manuals
- Cabletron Systems product data sheets
- information booklets
- or energy labels Cabletron Systems 9F426-03
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cabletron Systems 9F426-03.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cabletron Systems 9F426-03, service manual, brief instructions and user manuals Cabletron Systems 9F426-03. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cabletron Systems 9F426-03.

A complete manual for the device Cabletron Systems 9F426-03, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cabletron Systems 9F426-03 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cabletron Systems 9F426-03.

A complete Cabletron Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cabletron Systems 9F426-03 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cabletron Systems 9F426-03, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cabletron Systems 9F426-03, that we can find in the current document
3. Tips how to use the basic functions of the device Cabletron Systems 9F426-03 - which should help us in our first steps of using Cabletron Systems 9F426-03
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cabletron Systems 9F426-03
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cabletron Systems 9F426-03 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cabletron Systems 9F426-03?

Use the form below

If you did not solve your problem by using a manual Cabletron Systems 9F426-03, ask a question using the form below. If a user had a similar problem with Cabletron Systems 9F426-03 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)