Manual ResMed Positive Airway Pressure Device S8

20 pages 0.22 mb
Download

Go to site of 20

Summary
  • ResMed Positive Airway Pressure Device S8 - page 1

    S8 Lightw eight™ II POSITIVE AIRWA Y PRESSURE DEVI CE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Driv e Bella Vista NSW 2153 A ustralia • ResMed Corp (US Designated Agent) 1 4040 Danielson Street P owa y CA 92064-6857 USA • ResMed (UK) Ltd (EU Authorized Representative) 96 Milton P ark Abingdon Oxfordshire OX1 4 4R Y U ...

  • ResMed Positive Airway Pressure Device S8 - page 2

    i Contents Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 A dverse Ef f ects 1 The S8 Lightweight II S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Masks 2 Humidifiers 2 R esScan Dat a Card 2 Using the S8 Lightweight II . . . . . . . . ...

  • ResMed Positive Airway Pressure Device S8 - page 3

    1 Introduction Introduction The S8 Lightweight II continuous posit ive airway pressure (CPAP) system is indicated for the treatment of obstructive sleep ap noea (OSA) in patients > 30 kg. The S8 Lightweight II CPAP system is intended for home and hospital use. Contraindications The S8 Lightweight II is not a life sup port device and may stop ope ...

  • ResMed Positive Airway Pressure Device S8 - page 4

    2 The S8 Lightweight II System Your S8 Lightweight II comprises: • S8 Lightweight II positive air wa y pressu re de vice • 2 m air t ubing • P ow er cord • Carr y bag. Optional compon ents include: • Re sScan™ Dat a Card • 3 m air t ubing • DC-1 2 conv erter . Masks For information on us i ng masks, see your mask manual. Recommended ...

  • ResMed Positive Airway Pressure Device S8 - page 5

    3 Using the S8 Lightweight II Using the S8 Lightweight II ! WARNING • Make sure the power cord an d plug are in good condi tion and the equipment i s not dama ged. • Only R esMed air tubing shou ld be us ed with the device . A dif ferent type of air tubing may alter th e pressure you actually recei ve, reducing the ef fecti veness of your treat ...

  • ResMed Positive Airway Pressure Device S8 - page 6

    4 Start Treatment 1 Make sure the power is on. The product name is disp layed briefl y on the LCD screen, then the standb y (Ramp) screen appears. The key and L CD backlights also turn on. 2 Lie down and arrange the air tubing so that it is free to move if you turn in your sleep. ! CAUTION Do not leave long lengths of air tubi ng around the top of ...

  • ResMed Positive Airway Pressure Device S8 - page 7

    5 Using the S8 Lightweight II The S8 Lightweight II keyp ad has the following keys: The keypad and LCD are equippe d with backlights that come on when the devi ce is powered. The LCD backlight turns off after two minutes of inactivity, and comes back on when you press a key. T he keypad backlight is always on while the S8 Lightweight II is on. Key ...

  • ResMed Positive Airway Pressure Device S8 - page 8

    6 How to Change the Settings on your S8 Lightweight II You can change settings (such as Ramp Time) on the S8 Lightweight II by using the keypad and L CD. When the S8 Lig htweight II is in standby m ode you can display a series of screens (a menu) on the LCD screen in order to view and change the settings for a particular function. Use the menu scre ...

  • ResMed Positive Airway Pressure Device S8 - page 9

    7 Using the S8 Lightweight II 1 . On the st andby (RAMP) screen, press . 2. Press until you see EPR LEVEL, th en press (Change). 3. Press o r until you see the setting that you require. 4. Press (Apply) to save the setting. How to change the language setting 1 . On the stan db y (Ramp) screen, press (Menu). 2. Press until you see LANG (Language), t ...

  • ResMed Positive Airway Pressure Device S8 - page 10

    8 Using the Data Card to Collect data If your clinician needs to review your tr eatment, they will ask you to use the Data Card to copy data from your S8 Lightweight II, and to return th e card to them. The Data Card will be provided in a protective folder. Data that is copied to a Data Card is still stored and available on the S8 Lightweight II. C ...

  • ResMed Positive Airway Pressure Device S8 - page 11

    9 Cleaning and Maintenance ! CAUTION • Do not hang the air tubing in direct sunligh t as it may harden o ver time and eventually crac k. • Do not use bleac h, c hlori ne, alcohol, or aromatic-based solutions , moisturising or ant ibacter ial soaps or scented oils to clean the air tubing or the S8 Lightwei ght II. These solutions may caus e hard ...

  • ResMed Positive Airway Pressure Device S8 - page 12

    10 Servicing ! CAUTION • Do not at tempt to open the S8 Ligh tweight II case. Th ere are no user serviceable par ts inside. • Inspection and rep air should only be perform ed by an authorised agen t. Under no circumstances sh ould you attempt to serv ice or repair the S8 Lightweight II yourself. This device is intended to provide safe and relia ...

  • ResMed Positive Airway Pressure Device S8 - page 13

    11 T roubleshooting Anything specia l I should do before putting the mask on? Before wearing your mask, wash your face to remove excess facial oils. This will allow a better fit and prolong the life of the mask cushion. Do not use moisturiser when wearing a mask. My mouth feels dry during treatment—what can I do? You may experience dryness of the ...

  • ResMed Positive Airway Pressure Device S8 - page 14

    12 Insuf ficient air deliver ed fr om S8 Lightw eight II The f ollow ing messag e is displa yed on the LCD af t er you try t o update setting s or cop y data to the D ata Card: Card Error Remove Card The f ollow ing messag e is displa yed on the LCD af t er you try t o update setting s or cop y data to the D ata Card: Settings Invalid Remove Card T ...

  • ResMed Positive Airway Pressure Device S8 - page 15

    13 T echnical Specifications Technical Specifications . Note: The manufac turer reserves the right to change th ese specification s without notice. Operating pressur e range 4 to 20 c m H 2 O Dimens ions (H x W x D ) 112 mm x 16 4 mm x 145 mm W eight 1.3 kg P ow er Sup ply • Input range fo r S8 Light weight II with HumidAire 4i :1 0 0–240V , 50 ...

  • ResMed Positive Airway Pressure Device S8 - page 16

    14 Symbols which appear on the device At tention, consult accompanying documents; Follow inst ructions for us e; Drip proof; T y pe CF equipment; Danger ous voltage; Class II equipment; St art/Stop; Manufactu rer; Environmental infor mation WEEE 2002/96/EC is a Euro pean Directive that re quire s the proper disposal of electrical and electronic eq ...

  • ResMed Positive Airway Pressure Device S8 - page 17

    15 General W arnings and Cautions • In the ev ent of pow er failure or mac hine malfunction, remov e the mask. • The S8 Lightweight II can be set to deliver pressures up to 20 cm H 2 O. I n t h e unlik ely ev ent of certain fault cond itions, pressures up to 30 cm H 2 O are possible. • If o xygen is used with this de vice, the oxy gen flow mu ...

  • ResMed Positive Airway Pressure Device S8 - page 18

    16 Limited Warranty ResMed warrants that your ResMed product shall be free from defe cts in material and workmanship for the period sp ecified below from the date of purchas e by the initia l consumer. Th is warranty is no t transferable. Not e: Some models are not avai lable in all regions. If the product fails under conditions o f normal use, Res ...

  • ResMed Positive Airway Pressure Device S8 - page 19

    17 Limited W arranty ...

  • ResMed Positive Airway Pressure Device S8 - page 20

    18 ...

Manufacturer ResMed Category Respiratory Product

Documents that we receive from a manufacturer of a ResMed Positive Airway Pressure Device S8 can be divided into several groups. They are, among others:
- ResMed technical drawings
- Positive Airway Pressure Device S8 manuals
- ResMed product data sheets
- information booklets
- or energy labels ResMed Positive Airway Pressure Device S8
All of them are important, but the most important information from the point of view of use of the device are in the user manual ResMed Positive Airway Pressure Device S8.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ResMed Positive Airway Pressure Device S8, service manual, brief instructions and user manuals ResMed Positive Airway Pressure Device S8. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ResMed Positive Airway Pressure Device S8.

A complete manual for the device ResMed Positive Airway Pressure Device S8, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ResMed Positive Airway Pressure Device S8 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ResMed Positive Airway Pressure Device S8.

A complete ResMed manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ResMed Positive Airway Pressure Device S8 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ResMed Positive Airway Pressure Device S8, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ResMed Positive Airway Pressure Device S8, that we can find in the current document
3. Tips how to use the basic functions of the device ResMed Positive Airway Pressure Device S8 - which should help us in our first steps of using ResMed Positive Airway Pressure Device S8
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ResMed Positive Airway Pressure Device S8
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ResMed Positive Airway Pressure Device S8 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ResMed Positive Airway Pressure Device S8?

Use the form below

If you did not solve your problem by using a manual ResMed Positive Airway Pressure Device S8, ask a question using the form below. If a user had a similar problem with ResMed Positive Airway Pressure Device S8 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)