  • Bryant 394HAD - page 1

    NOTE: Read the entire instruction manual before starting the installation. These procedures are for sizes 65,000 through 150,000 Btuh units. Index Page SAFETY CONSIDERATIONS .....................................................1 CARE AND MAINTENANCE..................................................1-5 Air Filter Arrangement ........................ ...

  • Bryant 394HAD - page 2

    WARNING: Turn off the gas and electrical supplies to the unit before performing any maintenance or service. Follow the operating instructions on the label attached to the furnace. A failure to follow this warning could result in personal injury. WARNING: Never store anything on, near, or in contact with the furnace, such as: 1. Spray or aerosol can ...

  • Bryant 394HAD - page 3

    b. Remove blower and control access doors. c. Release filter retainer from clip at front of furnace casing. (See Fig. 4.) For side return, clips may be used on either or both sides of the furnace. d. Slide filter out. e. Furnaces are equipped with permanent, washable filters. Clean filters with tap water. Spray water through filter in opposite dire ...

  • Bryant 394HAD - page 4

    b. Remove screws holding cutoff plate and remove cutoff plate from housing. c. Lift blower wheel from housing through opening. 14. Clean blower wheel and motor using a vacuum cleaner with soft brush attachment. Do not remove or disturb balance weights (clips) on blower wheel blades. The blower wheel should not be dropped or bent as balance will be ...

  • Bryant 394HAD - page 5

    12. Reconnect wires to the following components: a. Draft safeguard switch b. Inducer motor c. Pressure switch d. Limit overtemperature switch e. Gas valve f. Edge connector leading to control box 13. Reconnect vent pipe to relief box. Replace vent pipe enclosure (downflow furnace only). 14. Replace blower access door only and secure with 2 screws ...

  • Bryant 394HAD - page 6

    Fig. 8—Heating and Cooling Application Wiring Diagram A78461 115-VOLT FIELD- SUPPLIED FUSED DISCONNECT AUXILIARY J-BOX CONTROL BOX 24-VOLT TERMINAL BLOCK TWO-WIRE HEATING- ONLY FOUR WIRE FIELD-SUPPLIED FUSED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE R G C W R G Y GND GND FIELD 24-VOLT WIRING FIELD ...

  • Bryant 394HAD - page 7

    Fig. 9—Unit Wiring Diagram A92176 FU1 IDR PL1-3 PR-1 PR-2 SEC-1 SEC-2 TRAN 24VAC 115VAC BLWM LO MED LO MED HI HI COM CAP L2 COM 4 3 2 1 C CFR HFR PL4 NOTE#4 NOTE#8 EAC-1 EAC-2 L1 ILK EQUIPMENT GROUND TO 115V AC FIELD DISCONNECTIONS NOTE #5 NOTE#10 PL2 L1 L2 PL1-1 IDR PL1-4 ALS FL LS PL1-7 R Y W G C NOTE #1 CFR NOTE #10 PL1-2 PL1-6 NC NO PRS C ...

  • Bryant 394HAD - page 8

    A91253 Is 24VAC across pressure switch N/O contact & screw C on board? YES NO Is 24VAC across pressure switch N/O contact & screw C on board? Is heat exchanger pressure drop greater than 0.35-in. wc? Is 24VAC across gas valve? Is unit lit? Check/Replace: 1. Vent systems 2. Induce wheel 3 ...

Manufacturer Bryant Category Furnace

Documents that we receive from a manufacturer of a Bryant 394HAD can be divided into several groups. They are, among others:
- Bryant technical drawings
- 394HAD manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 394HAD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 394HAD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 394HAD, service manual, brief instructions and user manuals Bryant 394HAD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 394HAD.

Similar manuals

A complete manual for the device Bryant 394HAD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 394HAD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 394HAD.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 394HAD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 394HAD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 394HAD, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 394HAD - which should help us in our first steps of using Bryant 394HAD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 394HAD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 394HAD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 394HAD?

Use the form below

If you did not solve your problem by using a manual Bryant 394HAD, ask a question using the form below. If a user had a similar problem with Bryant 394HAD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)