  • Cleveland Range SD-1200-K 612 - page 1

    SE95008 Rev . 6 Operators Manual Installation, Operation & Service Direct Steam T able T op Kettles T able-T op Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050 SD -1200 SD -1600 SD -1800 Kettles on SD Stands MODELS: SD - 450 - K 6 SD - 650 - K 12 SD - 760 ...

  • Cleveland Range SD-1200-K 612 - page 2

    Shut off pow er at main fuse disconnect prior to ser vicing. Ensure kettle is at room temperature and pressure gauge is showing z ero or less prior to removing any fittings . Inspect unit daily f or proper operation. 0 Do not fill kettle abo ve recommended le vel marked on outside of k ettle. Surf aces may be e xtremely hot! Use protectiv e equipme ...

  • Cleveland Range SD-1200-K 612 - page 3

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage. This unit is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NSF , ASME/Ntl.Bd., C ...

  • Cleveland Range SD-1200-K 612 - page 4

    STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Generally , kettles requir e 1/2" i.p.s. pipe, 10-45 psi steam pressur e. If the steam supply pressure exceeds 45 psi, a pressur e reducing valve is requir ed. The steam ...

  • Cleveland Range SD-1200-K 612 - page 5

    OPERA TION 1. Ensure that ther e is an adequate steam supply to the kettle. 2. T urn the steam control valve to the open position by turning the knob counter -clockwise, then allow the kettle to preheat. NOTE: When cooking egg and milk products, the kettle should NOT be preheated, as pr oducts of this nature adher e to hot cooking sur faces. These ...

  • Cleveland Range SD-1200-K 612 - page 6

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland Range SD-1200-K 612 - page 7

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Range SD-1200-K 612 - page 8

    STEAM CONTROL ASSEMBL Y SER VICE P AR TS 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 27 29 11 ...

  • Cleveland Range SD-1200-K 612 - page 9

    STEAM CONTROL ASSEMBL Y ITEM NO. P ART NO. DESCRIPTION QTY . 1. F A11056 Binding Head Screw , 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 T runnion, condensate return . . . ...

  • Cleveland Range SD-1200-K 612 - page 10

    3 4 7 6 5 11 10 9 8 16 12 13 15 14 22 21 19 18 20 See Steam Control Drawing 2 1 1 1 24 28 1 25 26 27 30 See Steam Control Drawing 23 17 Steam In Configuration for SD Stand with Two Kettles 2 2 CONDENSATE RETURN STEAM IN STEAM IN CONDENSATE RETURN See Steam Control Drawing STEAM IN STEAM IN 29 PLUMBING ASSEMBL Y (for SD Stands) ...

  • Cleveland Range SD-1200-K 612 - page 11

    PLUMBING ASSEMBL Y (for SD Stands) ITEM NO. P ART NO. DESCRIPTION QTY . 1. FI00169 T ee, 1/2" NPT . (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . . .3 2. KE54941-5 Safety V alve, 50 PSI, 1/2" (North America) (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . ...

  • Cleveland Range SD-1200-K 612 - page 12

    6 7 8 4 5 1 4 2 3 1 2 3 11 12 9 11 12 10 F AUCET ASSEMBLIES ...

  • Cleveland Range SD-1200-K 612 - page 13

    F AUCET ASSEMBLIES ITEM NO. P ART NO. DESCRIPTION QTY . 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SD-1200-K 612 - page 14

    STEAM CONTROL ASSEMBL Y - FOR KETTLES WITH GEARBO X See Tilting Gearbox Assembly 1 2 3 4 5 6 5 6 7 8 9 10 11 11 12 14 15 16 17 19 18 20 21 22 10 13 ...

  • Cleveland Range SD-1200-K 612 - page 15

    STEAM CONTROL ASSEMBL Y - FOR KETTLES WITH GEARBO X ITEM NO. P ART NO. DESCRIPTION QTY . 1. KE52697 Lock Nut, 1/2" NPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. F A32500 Lockwasher . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3 ...

  • Cleveland Range SD-1200-K 612 - page 16

    3 3 5 6 4 7 8 7 9 12 13 12 2 11 14 16 15 10 1 14 1 NOTE: Item # 14 to be tack welded flush outside in the gearbox housing (item #1 ). Do not damage the outside edges of the gearbox housing when tack welding. 2 See Steam Control Assembly TIL TING GEARBOX ASSEMBL Y - FOR KETTLES WITH GEARBO X ...

  • Cleveland Range SD-1200-K 612 - page 17

    TIL TING GEARBOX ASSEMBL Y - FOR KETTLES WITH GEARBO X ITEM NO. P ART NO. DESCRIPTION QTY . 1.-16. KE02062-1 Tilting Gearbox Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. KE02060 Gearbox Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE50 ...

  • Cleveland Range SD-1200-K 612 - page 18

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve (optional on kettles) must be checked at least twice a year as part of the normal maintenance per for med. 1. Open steam valve and preheat kettle. 2. Stand to the side of the pressur e relief valve discharge tube and pull ring three or four times to insure fr ee movement. Hold val ...

  • Cleveland Range SD-1200-K 612 - page 19

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and powered by a generator the units should b ...

  • Cleveland Range SD-1200-K 612 - page 20

    9.88" 251mm 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN 8.00" 203mm 9.38" 238mm 12.25" 311mm 12.50" 318mm 8.13" 207mm 9.31" 236mm 1.56" 40mm 3.50" 89mm SPECIFICA TION DRA WINGS KDT -1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF ACES: Right - 4" Left - 0 Back - 0 ...

  • Cleveland Range SD-1200-K 612 - page 21

    F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D H 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN STEAM CONTROL VALVE K M L N J 1.00" 25mm 1.25"/32mm WALL 2.25" 57mm GAL. LITRE A B C D E F G H J K L M N 31 1 IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 mm 356 254 384 317 210 254 ...

  • Cleveland Range SD-1200-K 612 - page 22

    F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN K M J 1.75" 45mm WALL H STEAM CONTROL VALVE 1.25" 32mm 2.25" 57mm L MARINE LOCK GAL. LITRE A B C D E F G H J K L M 31 1 IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 mm 521 425 584 565 343 ...

  • Cleveland Range SD-1200-K 612 - page 23

    SD ST ANDS WITH KETTLES CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF ACES: Right - 0 Left - 0 Back - 0 MARINE LOCK SLIDING DRAIN PAN 18.00" 457mm 6.00" 152mm A 27.75" 706mm 22.00" 610mm 1.47" 37mm 1.47" 37mm H C 16.88" 429mm 13.75" 349mm 33.50" 851mm D 5.00" 127mm 3.25" 83mm B ...

Manufacturer Cleveland Range Category Hot Beverage Maker

Documents that we receive from a manufacturer of a Cleveland Range SD-1200-K 612 can be divided into several groups. They are, among others:
- Cleveland Range technical drawings
- SD-1200-K 612 manuals
- Cleveland Range product data sheets
- information booklets
- or energy labels Cleveland Range SD-1200-K 612
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cleveland Range SD-1200-K 612.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cleveland Range SD-1200-K 612, service manual, brief instructions and user manuals Cleveland Range SD-1200-K 612. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cleveland Range SD-1200-K 612.

A complete manual for the device Cleveland Range SD-1200-K 612, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cleveland Range SD-1200-K 612 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cleveland Range SD-1200-K 612.

A complete Cleveland Range manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cleveland Range SD-1200-K 612 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cleveland Range SD-1200-K 612, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cleveland Range SD-1200-K 612, that we can find in the current document
3. Tips how to use the basic functions of the device Cleveland Range SD-1200-K 612 - which should help us in our first steps of using Cleveland Range SD-1200-K 612
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cleveland Range SD-1200-K 612
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cleveland Range SD-1200-K 612 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cleveland Range SD-1200-K 612?

Use the form below

If you did not solve your problem by using a manual Cleveland Range SD-1200-K 612, ask a question using the form below. If a user had a similar problem with Cleveland Range SD-1200-K 612 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)